Setting this value will cause the UPS output to turn off
after the set number of seconds, then restart (after a UPS-defined
'down time') when the utility is again available.
Unlike UpsControlOutputOffDelay, which might or might not,
this object always maps to the XCP 0x8A Load Dump & Restart command,
so the desired shutdown and restart behavior is guaranteed to happen.
Once set, this command cannot be aborted.
This is the preferred Control object to use when performing an On
Battery OS Shutdown.
Parsed from file CPQPOWER1.62.MIB.txt
Company: None
Module: CPQPOWER-MIB
Setting this value will cause the UPS output to turn off
after the set number of seconds, then restart (after a UPS-defined
'down time') when the utility is again available.
Unlike UpsControlOutputOffDelay, which might or might not,
this object always maps to the XCP 0x8A Load Dump & Restart command,
so the desired shutdown and restart behavior is guaranteed to happen.
Once set, this command cannot be aborted.
This is the preferred Control object to use when performing an On
Battery OS Shutdown.
Parsed from file CPQPOWER-MIB.mib
Module: CPQPOWER-MIB
upsLoadShedSecsWithRestart OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "Setting this value will cause the UPS output to turn off after the set number of seconds, then restart (after a UPS-defined 'down time') when the utility is again available. Unlike UpsControlOutputOffDelay, which might or might not, this object always maps to the XCP 0x8A Load Dump & Restart command, so the desired shutdown and restart behavior is guaranteed to happen. Once set, this command cannot be aborted. This is the preferred Control object to use when performing an On Battery OS Shutdown." ::= { upsControl 6 }
Vendor: Compaq
Module: CPQPOWER-MIB
[Automatically extracted from oidview.com]
upsLoadShedSecsWithRestart OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "Setting this value will cause the UPS output to turn off after the set number of seconds, then restart (after a UPS-defined 'down time') when the utility is again available. Unlike UpsControlOutputOffDelay, which might or might not, this object always maps to the XCP 0x8A Load Dump & Restart command, so the desired shutdown and restart behavior is guaranteed to happen. Once set, this command cannot be aborted. This is the preferred Control object to use when performing an On Battery OS Shutdown." ::= { upsControl 6 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.232.165.3.8.1 | upsControlOutputOffDelay | 0 | 0 | Setting this value to other than zero will cause the UPS output to turn off after the number of seconds. Setting it to 0 will cau… |
1.3.6.1.4.1.232.165.3.8.2 | upsControlOutputOnDelay | 0 | 0 | Setting this value to other than zero will cause the UPS output to turn on after the number of seconds. Setting it to 0 will caus… |
1.3.6.1.4.1.232.165.3.8.3 | upsControlOutputOffTrapDelay | 0 | 0 | upsControlOutputOfftrapDelay |
1.3.6.1.4.1.232.165.3.8.4 | upsControlOutputOnTrapDelay | 0 | 0 | When UpsControlOutputOnDelay reaches this value, a UpsOutputOff trap will be sent. |
1.3.6.1.4.1.232.165.3.8.5 | upsControlToBypassDelay | 0 | 0 | Setting this value to other than zero will cause the UPS output to go to Bypass after the number of seconds. If the Bypass is una… |