Reference record for OID 1.3.6.1.4.1.232.165.3.9.5


parent
1.3.6.1.4.1.232.165.3.9 (upsConfig)
node code
5
node name
upsConfigDateAndTime
dot oid
1.3.6.1.4.1.232.165.3.9.5
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) cpqPower(165) trapInformation(3) upsConfig(9) upsConfigDateAndTime(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) cpqPower(165) ups(3) upsConfig(9) upsConfigDateAndTime(5)}
  • ...skipped...
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) cpqPower(165) trapInformation(3) upsConfig(9) upsConfigDateAndTime(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) cpqPower(165) ups(3) upsConfig(9) upsConfigDateAndTime(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) cpqPower(165) trapInformation(3) upsConfig(9) upsConfigDateAndTime(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) cpqPower(165) ups(3) upsConfig(9) upsConfigDateAndTime(5)}
  • ...skipped...
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) cpqPower(165) trapInformation(3) upsConfig(9) upsConfigDateAndTime(5)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) cpqPower(165) ups(3) upsConfig(9) upsConfigDateAndTime(5)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/cpqPower/trapInformation/upsConfig/upsConfigDateAndTime
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/cpqPower/ups/upsConfig/upsConfigDateAndTime
  • ...skipped...
  • /iso/org/dod/internet/private/enterprise/hp/cpqPower/trapInformation/upsConfig/upsConfigDateAndTime
  • /iso/org/dod/internet/private/enterprise/hp/cpqPower/ups/upsConfig/upsConfigDateAndTime
  • /iso/org/dod/internet/private/enterprises/compaq/cpqPower/trapInformation/upsConfig/upsConfigDateAndTime
  • /iso/org/dod/internet/private/enterprises/compaq/cpqPower/ups/upsConfig/upsConfigDateAndTime
  • ...skipped...
  • /iso/iso-identified-organization/dod/internet/private/enterprises/hp/cpqPower/trapInformation/upsConfig/upsConfigDateAndTime
  • /iso/iso-identified-organization/dod/internet/private/enterprises/hp/cpqPower/ups/upsConfig/upsConfigDateAndTime
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/232/165/3/9/5

    Description by mibdepot

    Date and time information for the UPS. Setting this variable
    will initiate a set UPS date and time to this value. Reading
    this variable will return the UPS time and date. This value
    is not referenced to sysUpTime. It is simply the clock value
    from the UPS real time clock.
    Format is as follows: MM/DD/YYYY:HH:MM:SS.

    Parsed from file CPQPOWER1.62.MIB.txt
    Company: None
    Module: CPQPOWER-MIB

    Description by circitor

    Date and time information for the UPS. Setting this variable
    will initiate a set UPS date and time to this value. Reading
    this variable will return the UPS time and date. This value
    is not referenced to sysUpTime. It is simply the clock value
    from the UPS real time clock.
    Format is as follows: MM/DD/YYYY:HH:MM:SS.

    Parsed from file CPQPOWER-MIB.mib
    Module: CPQPOWER-MIB

    Information by mibdepot

    upsConfigDateAndTime OBJECT-TYPE SYNTAX DisplayString (SIZE (0..22)) ACCESS read-write STATUS mandatory DESCRIPTION "Date and time information for the UPS. Setting this variable will initiate a set UPS date and time to this value. Reading this variable will return the UPS time and date. This value is not referenced to sysUpTime. It is simply the clock value from the UPS real time clock. Format is as follows: MM/DD/YYYY:HH:MM:SS." ::= { upsConfig 5 }

    Information by oid_info

    Vendor: Compaq
    Module: CPQPOWER-MIB

    [Automatically extracted from oidview.com]

    Information by circitor

    upsConfigDateAndTime OBJECT-TYPE SYNTAX DisplayString (SIZE (0..22)) ACCESS read-write STATUS mandatory DESCRIPTION "Date and time information for the UPS. Setting this variable will initiate a set UPS date and time to this value. Reading this variable will return the UPS time and date. This value is not referenced to sysUpTime. It is simply the clock value from the UPS real time clock. Format is as follows: MM/DD/YYYY:HH:MM:SS." ::= { upsConfig 5 }

    Brothers (6)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.232.165.3.9.1 upsConfigOutputVoltage 0 0 The nominal UPS Output voltage per phase in volts.
    1.3.6.1.4.1.232.165.3.9.2 upsConfigInputVoltage 0 0 The nominal UPS Input voltage per phase in volts.
    1.3.6.1.4.1.232.165.3.9.3 upsConfigOutputWatts 0 0 The nominal UPS available real power output in watts.
    1.3.6.1.4.1.232.165.3.9.4 upsConfigOutputFreq 0 0 The nominal output frequency in tenths of Hz.
    1.3.6.1.4.1.232.165.3.9.6 upsConfigLowOutputVoltageLimit 0 0 The Lower limit for acceptable Output Voltage, per the UPS
    specifications.
    1.3.6.1.4.1.232.165.3.9.7 upsConfigHighOutputVoltageLimit 0 0 The Upper limit for acceptable Output Voltage, per the UPS
    specifications.