The panel table entry containing all power parameters
for each panel.
Parsed from file CPQPOWER1.62.MIB.txt
Company: None
Module: CPQPOWER-MIB
The panel table entry containing all power parameters
for each panel.
Parsed from file CPQPOWER-MIB.mib
Module: CPQPOWER-MIB
pdrPanelEntry OBJECT-TYPE SYNTAX PdrPanelEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The panel table entry containing all power parameters for each panel." INDEX { pdrPanelIndex } ::= { pdrPanelTable 1 }
Vendor: Compaq
Module: CPQPOWER-MIB
[Automatically extracted from oidview.com]
pdrPanelEntry OBJECT-TYPE SYNTAX PdrPanelEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The panel table entry containing all power parameters for each panel." INDEX { pdrPanelIndex } ::= { pdrPanelTable 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.232.165.4.2.1.1.1 | pdrPanelIndex | 0 | 0 | Index for the pdrPanelEntry table. |
1.3.6.1.4.1.232.165.4.2.1.1.2 | pdrPanelFrequency | 0 | 0 | The present frequency reading for the panel voltage. |
1.3.6.1.4.1.232.165.4.2.1.1.3 | pdrPanelPower | 0 | 0 | The present power of the panel. |
1.3.6.1.4.1.232.165.4.2.1.1.4 | pdrPanelRatedCurrent | 0 | 0 | The present rated current of the panel. |
1.3.6.1.4.1.232.165.4.2.1.1.5 | pdrPanelMonthlyKWH | 0 | 0 | The accumulated KWH for this panel since the beginning of this calendar month or since the last reset. |
1.3.6.1.4.1.232.165.4.2.1.1.6 | pdrPanelYearlyKWH | 0 | 0 | The accumulated KWH for this panel since the beginning of this calendar year or since the last reset. |
1.3.6.1.4.1.232.165.4.2.1.1.7 | pdrPanelTotalKWH | 0 | 0 | The accumulated KWH for this panel since it was put into service or since the last reset. |
1.3.6.1.4.1.232.165.4.2.1.1.8 | pdrPanelVoltageA | 0 | 0 | The measured panel output voltage. |
1.3.6.1.4.1.232.165.4.2.1.1.9 | pdrPanelVoltageB | 0 | 0 | The measured panel output voltage. |
1.3.6.1.4.1.232.165.4.2.1.1.10 | pdrPanelVoltageC | 0 | 0 | The measured panel output voltage. |
1.3.6.1.4.1.232.165.4.2.1.1.11 | pdrPanelCurrentA | 0 | 0 | The measured panel output current. |
1.3.6.1.4.1.232.165.4.2.1.1.12 | pdrPanelCurrentB | 0 | 0 | The measured panel output current. |
1.3.6.1.4.1.232.165.4.2.1.1.13 | pdrPanelCurrentC | 0 | 0 | The measured panel output current. |
1.3.6.1.4.1.232.165.4.2.1.1.14 | pdrPanelLoadA | 0 | 0 | The percentage of load is the ratio of each output current to the rated output current to the panel. |
1.3.6.1.4.1.232.165.4.2.1.1.15 | pdrPanelLoadB | 0 | 0 | The percentage of load is the ratio of each output current to the rated output current to the panel. |
1.3.6.1.4.1.232.165.4.2.1.1.16 | pdrPanelLoadC | 0 | 0 | The percentage of load is the ratio of each output current to the rated output current to the panel. |