Reference record for OID 1.3.6.1.4.1.232.6.2.6.7.1.5



parent
1.3.6.1.4.1.232.6.2.6.7.1 (cpqHeFltTolFanEntry)
node code
5
node name
cpqHeFltTolFanType
dot oid
1.3.6.1.4.1.232.6.2.6.7.1.5
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) cpqHealth(6) cpqHeComponent(2) cpqHeThermal(6) cpqHeFltTolFanTable(7) cpqHeFltTolFanEntry(1) cpqHeFltTolFanType(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) cpqHealth(6) cpqHeComponent(2) cpqHeThermal(6) cpqHeFltTolFanTable(7) cpqHeFltTolFanEntry(1) cpqHeFltTolFanType(5)}
  • ...skipped...
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) cpqHealth(6) cpqHeComponent(2) cpqHeThermal(6) cpqHeFltTolFanTable(7) cpqHeFltTolFanEntry(1) cpqHeFltTolFanType(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) cpqHealth(6) cpqHeComponent(2) cpqHeThermal(6) cpqHeFltTolFanTable(7) cpqHeFltTolFanEntry(1) cpqHeFltTolFanType(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) cpqHealth(6) cpqHeComponent(2) cpqHeThermal(6) cpqHeFltTolFanTable(7) cpqHeFltTolFanEntry(1) cpqHeFltTolFanType(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) cpqHealth(6) cpqHeComponent(2) cpqHeThermal(6) cpqHeFltTolFanTable(7) cpqHeFltTolFanEntry(1) cpqHeFltTolFanType(5)}
  • ...skipped...
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) cpqHealth(6) cpqHeComponent(2) cpqHeThermal(6) cpqHeFltTolFanTable(7) cpqHeFltTolFanEntry(1) cpqHeFltTolFanType(5)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) cpqHealth(6) cpqHeComponent(2) cpqHeThermal(6) cpqHeFltTolFanTable(7) cpqHeFltTolFanEntry(1) cpqHeFltTolFanType(5)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/cpqHealth/cpqHeComponent/cpqHeThermal/cpqHeFltTolFanTable/cpqHeFltTolFanEntry/cpqHeFltTolFanType
  • /iso/identified-organization/dod/internet/private/enterprise/hp/cpqHealth/cpqHeComponent/cpqHeThermal/cpqHeFltTolFanTable/cpqHeFltTolFanEntry/cpqHeFltTolFanType
  • ...skipped...
  • /iso/org/dod/internet/private/enterprise/compaq/cpqHealth/cpqHeComponent/cpqHeThermal/cpqHeFltTolFanTable/cpqHeFltTolFanEntry/cpqHeFltTolFanType
  • /iso/org/dod/internet/private/enterprise/hp/cpqHealth/cpqHeComponent/cpqHeThermal/cpqHeFltTolFanTable/cpqHeFltTolFanEntry/cpqHeFltTolFanType
  • /iso/org/dod/internet/private/enterprises/compaq/cpqHealth/cpqHeComponent/cpqHeThermal/cpqHeFltTolFanTable/cpqHeFltTolFanEntry/cpqHeFltTolFanType
  • /iso/org/dod/internet/private/enterprises/hp/cpqHealth/cpqHeComponent/cpqHeThermal/cpqHeFltTolFanTable/cpqHeFltTolFanEntry/cpqHeFltTolFanType
  • ...skipped...
  • /iso/iso-identified-organization/dod/internet/private/enterprises/compaq/cpqHealth/cpqHeComponent/cpqHeThermal/cpqHeFltTolFanTable/cpqHeFltTolFanEntry/cpqHeFltTolFanType
  • /iso/iso-identified-organization/dod/internet/private/enterprises/hp/cpqHealth/cpqHeComponent/cpqHeThermal/cpqHeFltTolFanTable/cpqHeFltTolFanEntry/cpqHeFltTolFanType
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/232/6/2/6/7/1/5

    Description by mibdepot

    This specifies the type of fan.

    other(1)
    The type of fan could not be determined.

    tachOutput(2)
    The fan can increase speed for greater cooling. Implies
    spin detect.

    spinDetect(3)
    The fan can detect when the fan stops spinning.

    Parsed from file CPQHLTH3.MIB.txt
    Company: None
    Module: CPQHLTH-MIB

    Description by oid_info

    cpqHeFltTolFanType OBJECT-TYPE
    SYNTAX INTEGER {
    other(1),
    tachOutput(2),
    spinDetect(3)
    }
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
    "This specifies the type of fan.
    other(1)
    The type of fan could not be determined.
    tachOutput(2)
    The fan can increase speed for greater cooling. Implies
    spin detect.
    spinDetect(3)
    The fan can detect when the fan stops spinning."

    View at oid-info.com

    Description by circitor

    This specifies the type of fan.

    other(1)
    The type of fan could not be determined.

    tachOutput(2)
    The fan can increase speed for greater cooling. Implies
    spin detect.

    spinDetect(3)
    The fan can detect when the fan stops spinning.

    Parsed from file CPQHLTH-MIB.mib
    Module: CPQHLTH-MIB

    Information by mibdepot

    cpqHeFltTolFanType OBJECT-TYPE SYNTAX INTEGER { other(1), tachOutput(2), spinDetect(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the type of fan. other(1) The type of fan could not be determined. tachOutput(2) The fan can increase speed for greater cooling. Implies spin detect. spinDetect(3) The fan can detect when the fan stops spinning." ::= { cpqHeFltTolFanEntry 5 }

    Information by oid_info

    Automatically extracted from a module checked by a user of the Asnp syntax-checking tool

    Information by circitor

    cpqHeFltTolFanType OBJECT-TYPE SYNTAX INTEGER { other(1), tachOutput(2), spinDetect(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the type of fan. other(1) The type of fan could not be determined. tachOutput(2) The fan can increase speed for greater cooling. Implies spin detect. spinDetect(3) The fan can detect when the fan stops spinning." ::= { cpqHeFltTolFanEntry 5 }

    Brothers (11)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.232.6.2.6.7.1.1 cpqHeFltTolFanChassis 0 0 The System Chassis number.
    1.3.6.1.4.1.232.6.2.6.7.1.2 cpqHeFltTolFanIndex 0 0 A number that uniquely specifies this fan description.
    1.3.6.1.4.1.232.6.2.6.7.1.3 cpqHeFltTolFanLocale 0 0 This specifies the location of the fan in the system.
    1.3.6.1.4.1.232.6.2.6.7.1.4 cpqHeFltTolFanPresent 0 0 This specifies if the fan described is present in the system.
    1.3.6.1.4.1.232.6.2.6.7.1.6 cpqHeFltTolFanSpeed 0 0 This specifies the speed of the fan. This value will be set
    if the fan type is tachOutput.
    1.3.6.1.4.1.232.6.2.6.7.1.7 cpqHeFltTolFanRedundant 0 0 This specifies if the fan is in a redundant configuration.
    1.3.6.1.4.1.232.6.2.6.7.1.8 cpqHeFltTolFanRedundantPartner 0 0 This specifies the index of the redundant partner. A value
    of zero will be used if there is no redundant partner.
    1.3.6.1.4.1.232.6.2.6.7.1.9 cpqHeFltTolFanCondition 0 0 The condition of the fan.

    This value will be one of the following:
    other(1)
    Fan status detection is not supported by this system o…
    1.3.6.1.4.1.232.6.2.6.7.1.10 cpqHeFltTolFanHotPlug 0 0 This indicates if the fan is capable of being removed and/or
    inserted while the system is in an operational state.

    If the value i…
    1.3.6.1.4.1.232.6.2.6.7.1.11 cpqHeFltTolFanHwLocation 0 0 A text description of the hardware location, on complex
    multi SBB hardware only, for the fan.
    A NULL string indicates that the ha…
    1.3.6.1.4.1.232.6.2.6.7.1.12 cpqHeFltTolFanCurrentSpeed 0 0 The current speed of a fan in rpm - revolutions per minute.