Reference record for OID 1.3.6.1.4.1.232.8.2.2.3.1.4



parent
1.3.6.1.4.1.232.8.2.2.3.1 (cpqSsPowerSupplyEntry)
node code
4
node name
cpqSsPowerSupplyStatus
dot oid
1.3.6.1.4.1.232.8.2.2.3.1.4
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) cpqSsStorageSys(8) cpqSsDrvBox(2) cpqSsBoxExtended(2) cpqSsPowerSupplyTable(3) cpqSsPowerSupplyEntry(1) cpqSsPowerSupplyStatus(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) cpqSsStorageSys(8) cpqSsDrvBox(2) cpqSsBoxExtended(2) cpqSsPowerSupplyTable(3) cpqSsPowerSupplyEntry(1) cpqSsPowerSupplyStatus(4)}
  • ...skipped...
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) cpqSsStorageSys(8) cpqSsDrvBox(2) cpqSsBoxExtended(2) cpqSsPowerSupplyTable(3) cpqSsPowerSupplyEntry(1) cpqSsPowerSupplyStatus(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) cpqSsStorageSys(8) cpqSsDrvBox(2) cpqSsBoxExtended(2) cpqSsPowerSupplyTable(3) cpqSsPowerSupplyEntry(1) cpqSsPowerSupplyStatus(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) cpqSsStorageSys(8) cpqSsDrvBox(2) cpqSsBoxExtended(2) cpqSsPowerSupplyTable(3) cpqSsPowerSupplyEntry(1) cpqSsPowerSupplyStatus(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) cpqSsStorageSys(8) cpqSsDrvBox(2) cpqSsBoxExtended(2) cpqSsPowerSupplyTable(3) cpqSsPowerSupplyEntry(1) cpqSsPowerSupplyStatus(4)}
  • ...skipped...
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) cpqSsStorageSys(8) cpqSsDrvBox(2) cpqSsBoxExtended(2) cpqSsPowerSupplyTable(3) cpqSsPowerSupplyEntry(1) cpqSsPowerSupplyStatus(4)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) cpqSsStorageSys(8) cpqSsDrvBox(2) cpqSsBoxExtended(2) cpqSsPowerSupplyTable(3) cpqSsPowerSupplyEntry(1) cpqSsPowerSupplyStatus(4)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/cpqSsStorageSys/cpqSsDrvBox/cpqSsBoxExtended/cpqSsPowerSupplyTable/cpqSsPowerSupplyEntry/cpqSsPowerSupplyStatus
  • /iso/identified-organization/dod/internet/private/enterprise/hp/cpqSsStorageSys/cpqSsDrvBox/cpqSsBoxExtended/cpqSsPowerSupplyTable/cpqSsPowerSupplyEntry/cpqSsPowerSupplyStatus
  • ...skipped...
  • /iso/org/dod/internet/private/enterprise/compaq/cpqSsStorageSys/cpqSsDrvBox/cpqSsBoxExtended/cpqSsPowerSupplyTable/cpqSsPowerSupplyEntry/cpqSsPowerSupplyStatus
  • /iso/org/dod/internet/private/enterprise/hp/cpqSsStorageSys/cpqSsDrvBox/cpqSsBoxExtended/cpqSsPowerSupplyTable/cpqSsPowerSupplyEntry/cpqSsPowerSupplyStatus
  • /iso/org/dod/internet/private/enterprises/compaq/cpqSsStorageSys/cpqSsDrvBox/cpqSsBoxExtended/cpqSsPowerSupplyTable/cpqSsPowerSupplyEntry/cpqSsPowerSupplyStatus
  • /iso/org/dod/internet/private/enterprises/hp/cpqSsStorageSys/cpqSsDrvBox/cpqSsBoxExtended/cpqSsPowerSupplyTable/cpqSsPowerSupplyEntry/cpqSsPowerSupplyStatus
  • ...skipped...
  • /iso/iso-identified-organization/dod/internet/private/enterprises/compaq/cpqSsStorageSys/cpqSsDrvBox/cpqSsBoxExtended/cpqSsPowerSupplyTable/cpqSsPowerSupplyEntry/cpqSsPowerSupplyStatus
  • /iso/iso-identified-organization/dod/internet/private/enterprises/hp/cpqSsStorageSys/cpqSsDrvBox/cpqSsBoxExtended/cpqSsPowerSupplyTable/cpqSsPowerSupplyEntry/cpqSsPowerSupplyStatus
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/232/8/2/2/3/1/4

    Description by mibdepot

    Compaq Storage System Power Supply Status.

    The following values are defined:

    other(1)
    The agent is unable to determine if this storage system power
    supply bay is occupied.

    notInstalled(2)
    Nothing is installed in this power supply bay.

    ok(3)
    A power supply is installed and operating normally.

    failed(4)
    A power supply is installed and is no longer operating.
    Replace the power supply.

    Parsed from file CPQSTSYS2.MIB.txt
    Company: None
    Module: CPQSTSYS-MIB

    Description by circitor

    Storage System Power Supply Status.

    The following values are defined:

    other(1)
    The agent is unable to determine if this storage system power
    supply bay is occupied.

    notInstalled(2)
    Nothing is installed in this power supply bay.

    ok(3)
    A power supply is installed and operating normally.

    failed(4)
    A power supply is installed and is no longer operating.
    Replace the power supply.

    degraded(5)
    For composite power supplies, this indicates that at least one
    power supply has failed or lost power.

    Parsed from file CPQSTSYS-MIB.mib
    Module: CPQSTSYS-MIB

    Information by mibdepot

    cpqSsPowerSupplyStatus OBJECT-TYPE SYNTAX INTEGER { other(1), notInstalled(2), ok(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Power Supply Status. The following values are defined: other(1) The agent is unable to determine if this storage system power supply bay is occupied. notInstalled(2) Nothing is installed in this power supply bay. ok(3) A power supply is installed and operating normally. failed(4) A power supply is installed and is no longer operating. Replace the power supply." ::= { cpqSsPowerSupplyEntry 4 }

    Information by oid_info

    Vendor: Compaq
    Module: CPQSTSYS-MIB

    [Automatically extracted from oidview.com]

    Information by circitor

    cpqSsPowerSupplyStatus OBJECT-TYPE SYNTAX INTEGER { other(1), notInstalled(2), ok(3), failed(4), degraded(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Storage System Power Supply Status. The following values are defined: other(1) The agent is unable to determine if this storage system power supply bay is occupied. notInstalled(2) Nothing is installed in this power supply bay. ok(3) A power supply is installed and operating normally. failed(4) A power supply is installed and is no longer operating. Replace the power supply. degraded(5) For composite power supplies, this indicates that at least one power supply has failed or lost power." ::= { cpqSsPowerSupplyEntry 4 }

    Brothers (8)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.232.8.2.2.3.1.1 cpqSsPowerSupplyChassisIndex 0 0 Storage System Power Supply Chassis Index.

    The chassis index uniquely identifies a storage system chassis.
    1.3.6.1.4.1.232.8.2.2.3.1.2 cpqSsPowerSupplyIndex 0 0 Storage System Power Supply Bay.

    This index uniquely identifies a power supply bay.
    1.3.6.1.4.1.232.8.2.2.3.1.3 cpqSsPowerSupplyBay 0 0 Compaq Storage System Power Supply Bay.

    The following values are defined:

    other(1)
    The agent does not recognize the bay. You may …
    1.3.6.1.4.1.232.8.2.2.3.1.5 cpqSsPowerSupplyUpsStatus 0 0 Storage System Power Supply Uninterruptible Power Supply (UPS)
    Status.

    The following values are defined:

    other(1)
    The agent is unab…
    1.3.6.1.4.1.232.8.2.2.3.1.6 cpqSsPowerSupplyCondition 0 0 Storage System Power Supply Condition.

    This is the condition of the storage system chassis and all of
    its components. The follow…
    1.3.6.1.4.1.232.8.2.2.3.1.7 cpqSsPowerSupplySerialNumber 0 0 Storage System Power Supply Serial Number.

    This is the power supply's serial number. This can be used
    for identification purpose…
    1.3.6.1.4.1.232.8.2.2.3.1.8 cpqSsPowerSupplyBoardRevision 0 0 Storage System Power Supply Board Revision.

    This is the power supply board revision. If the board revision is
    not supported, the…
    1.3.6.1.4.1.232.8.2.2.3.1.9 cpqSsPowerSupplyFirmwareRevision 0 0 Storage System Power Supply Firmware Revision.

    This is the power supply firmware revision. If the firmware revision
    is not suppo…