Reference record for OID 1.3.6.1.4.1.232.8.2.2.4.1.4



parent
1.3.6.1.4.1.232.8.2.2.4.1 (cpqSsFanModuleEntry)
node code
4
node name
cpqSsFanModuleCondition
dot oid
1.3.6.1.4.1.232.8.2.2.4.1.4
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) cpqSsStorageSys(8) cpqSsDrvBox(2) cpqSsBoxExtended(2) cpqSsFanModuleTable(4) cpqSsFanModuleEntry(1) cpqSsFanModuleCondition(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) cpqSsStorageSys(8) cpqSsDrvBox(2) cpqSsBoxExtended(2) cpqSsFanModuleTable(4) cpqSsFanModuleEntry(1) cpqSsFanModuleCondition(4)}
  • ...skipped...
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) cpqSsStorageSys(8) cpqSsDrvBox(2) cpqSsBoxExtended(2) cpqSsFanModuleTable(4) cpqSsFanModuleEntry(1) cpqSsFanModuleCondition(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) cpqSsStorageSys(8) cpqSsDrvBox(2) cpqSsBoxExtended(2) cpqSsFanModuleTable(4) cpqSsFanModuleEntry(1) cpqSsFanModuleCondition(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) cpqSsStorageSys(8) cpqSsDrvBox(2) cpqSsBoxExtended(2) cpqSsFanModuleTable(4) cpqSsFanModuleEntry(1) cpqSsFanModuleCondition(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) cpqSsStorageSys(8) cpqSsDrvBox(2) cpqSsBoxExtended(2) cpqSsFanModuleTable(4) cpqSsFanModuleEntry(1) cpqSsFanModuleCondition(4)}
  • ...skipped...
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) cpqSsStorageSys(8) cpqSsDrvBox(2) cpqSsBoxExtended(2) cpqSsFanModuleTable(4) cpqSsFanModuleEntry(1) cpqSsFanModuleCondition(4)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) cpqSsStorageSys(8) cpqSsDrvBox(2) cpqSsBoxExtended(2) cpqSsFanModuleTable(4) cpqSsFanModuleEntry(1) cpqSsFanModuleCondition(4)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/cpqSsStorageSys/cpqSsDrvBox/cpqSsBoxExtended/cpqSsFanModuleTable/cpqSsFanModuleEntry/cpqSsFanModuleCondition
  • /iso/identified-organization/dod/internet/private/enterprise/hp/cpqSsStorageSys/cpqSsDrvBox/cpqSsBoxExtended/cpqSsFanModuleTable/cpqSsFanModuleEntry/cpqSsFanModuleCondition
  • ...skipped...
  • /iso/org/dod/internet/private/enterprise/compaq/cpqSsStorageSys/cpqSsDrvBox/cpqSsBoxExtended/cpqSsFanModuleTable/cpqSsFanModuleEntry/cpqSsFanModuleCondition
  • /iso/org/dod/internet/private/enterprise/hp/cpqSsStorageSys/cpqSsDrvBox/cpqSsBoxExtended/cpqSsFanModuleTable/cpqSsFanModuleEntry/cpqSsFanModuleCondition
  • /iso/org/dod/internet/private/enterprises/compaq/cpqSsStorageSys/cpqSsDrvBox/cpqSsBoxExtended/cpqSsFanModuleTable/cpqSsFanModuleEntry/cpqSsFanModuleCondition
  • /iso/org/dod/internet/private/enterprises/hp/cpqSsStorageSys/cpqSsDrvBox/cpqSsBoxExtended/cpqSsFanModuleTable/cpqSsFanModuleEntry/cpqSsFanModuleCondition
  • ...skipped...
  • /iso/iso-identified-organization/dod/internet/private/enterprises/compaq/cpqSsStorageSys/cpqSsDrvBox/cpqSsBoxExtended/cpqSsFanModuleTable/cpqSsFanModuleEntry/cpqSsFanModuleCondition
  • /iso/iso-identified-organization/dod/internet/private/enterprises/hp/cpqSsStorageSys/cpqSsDrvBox/cpqSsBoxExtended/cpqSsFanModuleTable/cpqSsFanModuleEntry/cpqSsFanModuleCondition
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/232/8/2/2/4/1/4

    Description by mibdepot

    Compaq Storage System Fan Module Condition.

    This is the condition of the storage system fan module.
    The following values are defined:

    other(1)
    The agent does not recognize the status. You may need to
    upgrade your software.

    ok(2)
    The fan module is operating normally. No user action is
    required.

    degraded(3)
    The fan module is degraded. You need to check the fan module
    for problems.

    failed(4)
    The fan module has failed. Replace the fan module.

    Parsed from file CPQSTSYS2.MIB.txt
    Company: None
    Module: CPQSTSYS-MIB

    Description by circitor

    Storage System Fan Module Condition.

    This is the condition of the storage system fan module.
    The following values are defined:

    other(1)
    The agent does not recognize the status. You may need to
    upgrade your software.

    ok(2)
    The fan module is operating normally. No user action is
    required.

    degraded(3)
    The fan module is degraded. You need to check the fan module
    for problems.

    failed(4)
    The fan module has failed. Replace the fan module.

    Parsed from file CPQSTSYS-MIB.mib
    Module: CPQSTSYS-MIB

    Information by mibdepot

    cpqSsFanModuleCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Fan Module Condition. This is the condition of the storage system fan module. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) The fan module is operating normally. No user action is required. degraded(3) The fan module is degraded. You need to check the fan module for problems. failed(4) The fan module has failed. Replace the fan module." ::= { cpqSsFanModuleEntry 4 }

    Information by oid_info

    Vendor: Compaq
    Module: CPQSTSYS-MIB

    [Automatically extracted from oidview.com]

    Information by circitor

    cpqSsFanModuleCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Storage System Fan Module Condition. This is the condition of the storage system fan module. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) The fan module is operating normally. No user action is required. degraded(3) The fan module is degraded. You need to check the fan module for problems. failed(4) The fan module has failed. Replace the fan module." ::= { cpqSsFanModuleEntry 4 }

    Brothers (6)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.232.8.2.2.4.1.1 cpqSsFanModuleChassisIndex 0 0 Storage System Fan Module Chassis Index.

    The chassis index uniquely identifies a storage system chassis.
    1.3.6.1.4.1.232.8.2.2.4.1.2 cpqSsFanModuleIndex 0 0 Storage System Fan Module Index.

    This index uniquely identifies a storage system fan module.
    1.3.6.1.4.1.232.8.2.2.4.1.3 cpqSsFanModuleStatus 0 0 Storage System Fan Module Status.

    The following values are defined:

    other(1)
    The agent is unable to determine if this storage syst…
    1.3.6.1.4.1.232.8.2.2.4.1.5 cpqSsFanModuleLocation 0 0 Compaq Storage System Fan Module Location.

    The following values are defined:

    other(1)
    The agent is unable to determine the locatio…
    1.3.6.1.4.1.232.8.2.2.4.1.6 cpqSsFanModuleSerialNumber 0 0 Storage System Fan Module Serial Number.

    This is the fan module's serial number. This can be used
    for identification purposes.
    1.3.6.1.4.1.232.8.2.2.4.1.7 cpqSsFanModuleBoardRevision 0 0 Storage System Fan Module Board Revision.

    This is the fan module board revision.