Compaq Storage System Fan Module Condition.
This is the condition of the storage system fan module.
The following values are defined:
other(1)
The agent does not recognize the status. You may need to
upgrade your software.
ok(2)
The fan module is operating normally. No user action is
required.
degraded(3)
The fan module is degraded. You need to check the fan module
for problems.
failed(4)
The fan module has failed. Replace the fan module.
Parsed from file CPQSTSYS2.MIB.txt
Company: None
Module: CPQSTSYS-MIB
Storage System Fan Module Condition.
This is the condition of the storage system fan module.
The following values are defined:
other(1)
The agent does not recognize the status. You may need to
upgrade your software.
ok(2)
The fan module is operating normally. No user action is
required.
degraded(3)
The fan module is degraded. You need to check the fan module
for problems.
failed(4)
The fan module has failed. Replace the fan module.
Parsed from file CPQSTSYS-MIB.mib
Module: CPQSTSYS-MIB
cpqSsFanModuleCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Fan Module Condition. This is the condition of the storage system fan module. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) The fan module is operating normally. No user action is required. degraded(3) The fan module is degraded. You need to check the fan module for problems. failed(4) The fan module has failed. Replace the fan module." ::= { cpqSsFanModuleEntry 4 }
Vendor: Compaq
Module: CPQSTSYS-MIB
[Automatically extracted from oidview.com]
cpqSsFanModuleCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Storage System Fan Module Condition. This is the condition of the storage system fan module. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) The fan module is operating normally. No user action is required. degraded(3) The fan module is degraded. You need to check the fan module for problems. failed(4) The fan module has failed. Replace the fan module." ::= { cpqSsFanModuleEntry 4 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.232.8.2.2.4.1.1 | cpqSsFanModuleChassisIndex | 0 | 0 | Storage System Fan Module Chassis Index. The chassis index uniquely identifies a storage system chassis. |
1.3.6.1.4.1.232.8.2.2.4.1.2 | cpqSsFanModuleIndex | 0 | 0 | Storage System Fan Module Index. This index uniquely identifies a storage system fan module. |
1.3.6.1.4.1.232.8.2.2.4.1.3 | cpqSsFanModuleStatus | 0 | 0 | Storage System Fan Module Status. The following values are defined: other(1) The agent is unable to determine if this storage syst… |
1.3.6.1.4.1.232.8.2.2.4.1.5 | cpqSsFanModuleLocation | 0 | 0 | Compaq Storage System Fan Module Location. The following values are defined: other(1) The agent is unable to determine the locatio… |
1.3.6.1.4.1.232.8.2.2.4.1.6 | cpqSsFanModuleSerialNumber | 0 | 0 | Storage System Fan Module Serial Number. This is the fan module's serial number. This can be used for identification purposes. |
1.3.6.1.4.1.232.8.2.2.4.1.7 | cpqSsFanModuleBoardRevision | 0 | 0 | Storage System Fan Module Board Revision. This is the fan module board revision. |