Compaq Storage System Fan Module Condition.
This is the condition of the storage system temperature sensor.
The following values are defined:
other(1)
The agent does not recognize the status. You may need to
upgrade your software.
ok(2)
The temperature is within normal operating range. No user
action is required.
degraded(3)
The temperature is outside of normal operating range.
failed(4)
The temperature could permanently damage the system.
The storage system will automatically shutdown if this
condition is detected.
Parsed from file CPQSTSYS2.MIB.txt
Company: None
Module: CPQSTSYS-MIB
Storage System Fan Module Condition.
This is the condition of the storage system temperature sensor.
The following values are defined:
other(1)
The agent does not recognize the status. You may need to
upgrade your software.
ok(2)
The temperature is within normal operating range. No user
action is required.
degraded(3)
The temperature is outside of normal operating range.
failed(4)
The temperature could permanently damage the system.
The storage system will automatically shutdown if this
condition is detected.
Parsed from file CPQSTSYS-MIB.mib
Module: CPQSTSYS-MIB
cpqSsTempSensorCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Fan Module Condition. This is the condition of the storage system temperature sensor. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) The temperature is within normal operating range. No user action is required. degraded(3) The temperature is outside of normal operating range. failed(4) The temperature could permanently damage the system. The storage system will automatically shutdown if this condition is detected." ::= { cpqSsTempSensorEntry 4 }
Vendor: Compaq
Module: CPQSTSYS-MIB
[Automatically extracted from oidview.com]
cpqSsTempSensorCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Storage System Fan Module Condition. This is the condition of the storage system temperature sensor. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) The temperature is within normal operating range. No user action is required. degraded(3) The temperature is outside of normal operating range. failed(4) The temperature could permanently damage the system. The storage system will automatically shutdown if this condition is detected." ::= { cpqSsTempSensorEntry 4 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.232.8.2.2.5.1.1 | cpqSsTempSensorChassisIndex | 0 | 0 | Storage System Temperature Sensor Chassis Index. The chassis index uniquely identifies a storage system chassis. |
1.3.6.1.4.1.232.8.2.2.5.1.2 | cpqSsTempSensorIndex | 0 | 0 | Storage System Temperature Sensor Index. This index uniquely identifies a temperature sensor. |
1.3.6.1.4.1.232.8.2.2.5.1.3 | cpqSsTempSensorStatus | 0 | 0 | Storage System Temperature Sensor Status. The following values are defined: other(1) The agent is unable to determine if the stora… |
1.3.6.1.4.1.232.8.2.2.5.1.5 | cpqSsTempSensorLocation | 0 | 0 | Storage System Fan Module Location. The following values are defined: other(1) The agent is unable to determine the location of th… |
1.3.6.1.4.1.232.8.2.2.5.1.6 | cpqSsTempSensorCurrentValue | 0 | 0 | Storage System Temperature Sensor Current Value. The current value of the temperature sensor in degrees Celsius. |
1.3.6.1.4.1.232.8.2.2.5.1.7 | cpqSsTempSensorLimitValue | 0 | 0 | Storage System Temperature Sensor Limit Value. The limit value of the temperature sensor in degrees Celsius. |
1.3.6.1.4.1.232.8.2.2.5.1.8 | cpqSsTempSensorHysteresisValue | 0 | 0 | Storage System Temperature Sensor Hysteresis Value. The hysteresis value of the temperature sensor in degrees Celsius. |