Description 1
This is the return path of mail.
Sources for this description
LANCOM official release MIBsLANCOM MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.2356.800.2.2127.1.3.2.5
This is the return path of mail.
Identification
{1 3 6 1 4 1 2356 800 2 2127 1 3 2 5}
Definitions may combine these properties differently.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 2 distinct definitions; some records may not include a definition.
es2126pEmailReturnPath OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the return path of mail."
::= { es2126pEmail 5 }es2126pEmailUserTable OBJECT-TYPE
SYNTAX SEQUENCE OF ES2126PEmailUserEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is a list of email user entry. The numbers of entries are given by the value of es2126pEmailUserNumber."
::= { es2126pEmail 5 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Description 1
This is the return path of mail.
LANCOM official release MIBsLANCOM MIB copies (LibreNMS/Observium Community)
Description 2
This is a list of email user entry. The numbers of entries are given by the value of es2126pEmailUserNumber.
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: es2126pEmailReturnPath
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"es2126pEmailReturnPath",
"OBJECT-TYPE",
"SYNTAX",
"DisplayString",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"This is the return path of mail.\"",
"::=",
"{",
"es2126pEmail",
"5",
"}"
],
"syntax_tree": [
[
"row",
"DisplayString"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This is the return path of mail."
],
null,
null,
null,
null
]
}Module: LANCOM-ES-2126P-MIB
See published definition above
{'SNMPv2-TC': ['DisplayString'], 'BRIDGE-MIB': ['MacAddress'], 'SNMPv2-SMI': ['enterprises', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Counter32', 'IpAddress'], 'RFC1213-MIB': ['ifIndex'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP']}Module: LANCOM-ES-2126P-MIB
{'SNMPv2-TC': ['DisplayString'], 'BRIDGE-MIB': ['MacAddress'], 'SNMPv2-SMI': ['enterprises', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Counter32', 'IpAddress'], 'RFC1213-MIB': ['ifIndex'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP']}Source data warning: The publisher uses an uppercase OBJECT-TYPE value name. Preserve the literal name, original definition and all numeric assignments.
· Download LC-ES2126P-2.99-RC1.mibSame file in LC-ES2126P-3.04-Rel.mib.
Vendor MIB copy from the Observium Community archive. LANCOM support.
Module: LANCOM-ES-2126P-MIB
{'SNMPv2-TC': ['DisplayString'], 'BRIDGE-MIB': ['MacAddress'], 'SNMPv2-SMI': ['enterprises', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Counter32', 'IpAddress'], 'RFC1213-MIB': ['ifIndex'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP']}Source data warning: The publisher uses an uppercase OBJECT-TYPE value name. Preserve the literal name, original definition and all numeric assignments.
· Download LANCOM-ES-2126P-MIBRelated source files and packages:
Status in source: current.
Names: es2126pEmailUserTable
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"es2126pEmailUserTable",
"OBJECT-TYPE",
"SYNTAX",
"SEQUENCE",
"OF",
"ES2126PEmailUserEntry",
"MAX-ACCESS",
"not-accessible",
"STATUS",
"current",
"DESCRIPTION",
"\"This is a list of email user entry. The numbers of entries are given by the value of es2126pEmailUserNumber.\"",
"::=",
"{",
"es2126pEmail",
"5",
"}"
],
"syntax_tree": [
[
"conceptualTable",
[
"row",
"ES2126PEmailUserEntry"
]
],
null,
[
"MaxAccessPart",
"not-accessible"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This is a list of email user entry. The numbers of entries are given by the value of es2126pEmailUserNumber."
],
null,
null,
null,
null
]
}Module: LANCOM-ES-2126P-MIB
See published definition above
{'SNMPv2-TC': ['DisplayString'], 'SNMPv2-SMI': ['enterprises', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Counter32', 'IpAddress'], 'RFC1213-MIB': ['ifIndex'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP']}Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.2356.800.2.2127.1.3.2.5.1 | es2126pEmailUserEntry | 2 | 2 |
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.2356.800.2.2127.1.3.2.1 | es2126pEmailServer | 0 | 0 | |
| 1.3.6.1.4.1.2356.800.2.2127.1.3.2.2 | es2126pEmailUsername | 0 | 0 | |
| 1.3.6.1.4.1.2356.800.2.2127.1.3.2.3 | es2126pEmailPassword | 0 | 0 | |
| 1.3.6.1.4.1.2356.800.2.2127.1.3.2.4 | es2126pEmailUserNumber, es2126pEmailSender | 0 | 0 | |
| 1.3.6.1.4.1.2356.800.2.2127.1.3.2.6 | es2126pEmailUserNumber | 0 | 0 | |
| 1.3.6.1.4.1.2356.800.2.2127.1.3.2.7 | es2126pEmailUserTable | 1 | 3 |