Reference record for OID 1.3.6.1.4.1.2474.1.4.2.0.1



parent
1.3.6.1.4.1.2474.1.4.2.0 (aviciBayNotificationPrefix)
node code
1
node name
aviciBayVoltageNotification
dot oid
1.3.6.1.4.1.2474.1.4.2.0.1
type
NOTIFICATION-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) avici(2474) aviciMibs(1) aviciBayMIB(4) aviciBayNotifications(2) aviciBayNotificationPrefix(0) aviciBayVoltageNotification(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) avici(2474) aviciMibs(1) aviciBayMIB(4) aviciBayNotifications(2) aviciBayNotificationPrefix(0) aviciBayVoltageNotification(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) avici(2474) aviciMibs(1) aviciBayMIB(4) aviciBayNotifications(2) aviciBayNotificationPrefix(0) aviciBayVoltageNotification(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) avici(2474) aviciMibs(1) aviciBayMIB(4) aviciBayNotifications(2) aviciBayNotificationPrefix(0) aviciBayVoltageNotification(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) avici(2474) aviciMibs(1) aviciBayMIB(4) aviciBayNotifications(2) aviciBayNotificationPrefix(0) aviciBayVoltageNotification(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) avici(2474) aviciMibs(1) aviciBayMIB(4) aviciBayNotifications(2) aviciBayNotificationPrefix(0) aviciBayVoltageNotification(1)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/avici/aviciMibs/aviciBayMIB/aviciBayNotifications/aviciBayNotificationPrefix/aviciBayVoltageNotification
  • /iso/identified-organization/dod/internet/private/enterprises/avici/aviciMibs/aviciBayMIB/aviciBayNotifications/aviciBayNotificationPrefix/aviciBayVoltageNotification
  • /iso/org/dod/internet/private/enterprise/avici/aviciMibs/aviciBayMIB/aviciBayNotifications/aviciBayNotificationPrefix/aviciBayVoltageNotification
  • /iso/org/dod/internet/private/enterprises/avici/aviciMibs/aviciBayMIB/aviciBayNotifications/aviciBayNotificationPrefix/aviciBayVoltageNotification
  • /iso/iso-identified-organization/dod/internet/private/enterprise/avici/aviciMibs/aviciBayMIB/aviciBayNotifications/aviciBayNotificationPrefix/aviciBayVoltageNotification
  • /iso/iso-identified-organization/dod/internet/private/enterprises/avici/aviciMibs/aviciBayMIB/aviciBayNotifications/aviciBayNotificationPrefix/aviciBayVoltageNotification
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/2474/1/4/2/0/1

    Description by mibdepot

    A Voltage notification is sent when a change is detected in the 5
    volt backplane communication rails. These backplane
    communication rails are used by the bay controller to
    communicate with the occupant of a given slot. There are 8
    rails, each servicing the slots in one half of a shelf in the
    bay (aviciBayVoltageIndex == rail):

    Rail Slots
    ==============
    1 1 - 5
    2 6 - 10
    3 11 - 15
    4 16 - 20
    5 21 - 25
    6 26 - 30
    7 31 - 35
    8 36 - 40

    If the voltage is out of specification, the communication path
    will not function. When a given backplane communication channel
    is not functioning, modules serviced by this rail cannot be
    discovered (if a module is inserted) and will not be authorized
    to boot (if an existing module reboots). The current voltage is
    reported in the aviciBayVoltage object. A human readable
    description of the event triggering this notification is
    included in the aviciSysTrapDescr object.

    Parsed from file AVICI-BAY-MIB.mib.txt
    Company: None
    Module: AVICI-BAY-MIB

    Description by circitor

    A Voltage notification is sent when a change is detected in the 5
    volt backplane communication rails. These backplane
    communication rails are used by the bay controller to
    communicate with the occupant of a given slot. There are 8
    rails, each servicing the slots in one half of a shelf in the
    bay (aviciBayVoltageIndex == rail):

    Rail Slots
    ==============
    1 1 - 5
    2 6 - 10
    3 11 - 15
    4 16 - 20
    5 21 - 25
    6 26 - 30
    7 31 - 35
    8 36 - 40

    If the voltage is out of specification, the communication path
    will not function. When a given backplane communication channel
    is not functioning, modules serviced by this rail cannot be
    discovered (if a module is inserted) and will not be authorized
    to boot (if an existing module reboots). The current voltage is
    reported in the aviciBayVoltage object. A human readable
    description of the event triggering this notification is
    included in the aviciSysTrapDescr object.

    Parsed from file AVICI-BAY-MIB.mib
    Module: AVICI-BAY-MIB

    Information by oid_info

    Vendor: Avici Systems, Inc.
    Module: AVICI-BAY-MIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    aviciBayVoltageNotification NOTIFICATION-TYPE OBJECTS { aviciBayIndex, aviciBayVoltageIndex, aviciBayVoltage, aviciBayVoltageStatus, aviciSysTrapDescr } STATUS current DESCRIPTION "A Voltage notification is sent when a change is detected in the 5 volt backplane communication rails. These backplane communication rails are used by the bay controller to communicate with the occupant of a given slot. There are 8 rails, each servicing the slots in one half of a shelf in the bay (aviciBayVoltageIndex == rail): Rail Slots ============== 1 1 - 5 2 6 - 10 3 11 - 15 4 16 - 20 5 21 - 25 6 26 - 30 7 31 - 35 8 36 - 40 If the voltage is out of specification, the communication path will not function. When a given backplane communication channel is not functioning, modules serviced by this rail cannot be discovered (if a module is inserted) and will not be authorized to boot (if an existing module reboots). The current voltage is reported in the aviciBayVoltage object. A human readable description of the event triggering this notification is included in the aviciSysTrapDescr object." ::= { aviciBayNotificationPrefix 1 }

    Information by circitor

    aviciBayVoltageNotification NOTIFICATION-TYPE OBJECTS { aviciBayIndex, aviciBayVoltageIndex, aviciBayVoltage, aviciBayVoltageStatus, aviciSysTrapDescr } STATUS current DESCRIPTION "A Voltage notification is sent when a change is detected in the 5 volt backplane communication rails. These backplane communication rails are used by the bay controller to communicate with the occupant of a given slot. There are 8 rails, each servicing the slots in one half of a shelf in the bay (aviciBayVoltageIndex == rail): Rail Slots ============== 1 1 - 5 2 6 - 10 3 11 - 15 4 16 - 20 5 21 - 25 6 26 - 30 7 31 - 35 8 36 - 40 If the voltage is out of specification, the communication path will not function. When a given backplane communication channel is not functioning, modules serviced by this rail cannot be discovered (if a module is inserted) and will not be authorized to boot (if an existing module reboots). The current voltage is reported in the aviciBayVoltage object. A human readable description of the event triggering this notification is included in the aviciSysTrapDescr object." ::= { aviciBayNotificationPrefix 1 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.2474)

    Gili Patrick

    Brothers (4)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.2474.1.4.2.0.2 aviciBayFanNotification 0 0 A Fan notification is sent when the specified fan detects a
    fault or clears a fault. The current ambient air temperature
    enterin…
    1.3.6.1.4.1.2474.1.4.2.0.3 aviciBayBreakerNotification 0 0 A Breaker notification is sent when the specified breaker has
    tripped or been manually reset. The breaker may have tripped
    due t…
    1.3.6.1.4.1.2474.1.4.2.0.4 aviciBayMultiFanFailures 0 0 Two or more fans have failed in this bay.
    1.3.6.1.4.1.2474.1.4.2.0.5 aviciBayMultiBayControllerFailures 0 0 Both bay controllers have failed in this bay.