This object identifies the switch within the system for which this entry contains information. This value can never be greater than switchNumber.
Sources for this description
Hirschmann MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.248.13.8.1.1.2.1.1
This object identifies the switch within the system for which this entry contains information. This value can never be greater than switchNumber.
Identification
{1 3 6 1 4 1 248 13 8 1 1 2 1 1}
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.
In smartLion, the row index swUnitIndex is declared as Integer32. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.248.13.8.1.1.2.1.1.<swUnitIndex>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.
A query example is omitted because the source variants do not establish compatible read access.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
swUnitIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This object identifies the switch within the system
for which this entry contains information. This
value can never be greater than switchNumber."
::= { switchInfoEntry 1 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
This object identifies the switch within the system for which this entry contains information. This value can never be greater than switchNumber.
Hirschmann MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: swUnitIndex
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"swUnitIndex",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"MAX-ACCESS",
"not-accessible",
"STATUS",
"current",
"DESCRIPTION",
"\"This object identifies the switch within the system for which this entry contains information. This value can never be greater than switchNumber.\"",
"::=",
"{",
"switchInfoEntry",
"1",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32"
],
null,
[
"MaxAccessPart",
"not-accessible"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This object identifies the switch within the system for which this entry contains information. This value can never be greater than switchNumber."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive. Hirschmann support.
Module: smartLion
See published definition above
{'SNMPv2-SMI': ['MODULE-IDENTITY', 'NOTIFICATION-TYPE'], 'RFC1155-SMI': ['internet'], 'HMPRIV-MGMT-SNMP-MIB': ['hirschmann']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.248.13.8.1.1.2.1.2 | swMainBoardHwVer | 0 | 0 | |
| 1.3.6.1.4.1.248.13.8.1.1.2.1.3 | swMainBoardFwVer | 0 | 0 | |
| 1.3.6.1.4.1.248.13.8.1.1.2.1.4 | swAgentBoardHwVer | 0 | 0 | |
| 1.3.6.1.4.1.248.13.8.1.1.2.1.5 | swAgentBoardFwVer | 0 | 0 | |
| 1.3.6.1.4.1.248.13.8.1.1.2.1.6 | swAgentBoardPOSTCodeVer | 0 | 0 | |
| 1.3.6.1.4.1.248.13.8.1.1.2.1.7 | swPortNumber | 0 | 0 | |
| 1.3.6.1.4.1.248.13.8.1.1.2.1.8 | swPowerStatus | 0 | 0 | |
| 1.3.6.1.4.1.248.13.8.1.1.2.1.9 | swExpansionSlot1 | 0 | 0 | |
| 1.3.6.1.4.1.248.13.8.1.1.2.1.10 | swExpansionSlot2 | 0 | 0 | |
| 1.3.6.1.4.1.248.13.8.1.1.2.1.11 | swRoleInSystem | 0 | 0 | |
| 1.3.6.1.4.1.248.13.8.1.1.2.1.12 | swFan1Status | 0 | 0 | |
| 1.3.6.1.4.1.248.13.8.1.1.2.1.13 | swFan2Status | 0 | 0 |