Reference record for OID 1.3.6.1.4.1.260.1.1.1.2.1.14



parent
1.3.6.1.4.1.260.1.1.1.2.1 (m828HubTableEntry)
node code
14
node name
m828HubRoFTolState
dot oid
1.3.6.1.4.1.260.1.1.1.2.1.14
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) startek(260) products(1) m828Series(1) m828Hubs(1) m828HubTable(2) m828HubTableEntry(1) m828HubRoFTolState(14)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) startek(260) products(1) m828Series(1) m828Hubs(1) m828HubTable(2) m828HubTableEntry(1) m828HubRoFTolState(14)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) startek(260) products(1) m828Series(1) m828Hubs(1) m828HubTable(2) m828HubTableEntry(1) m828HubRoFTolState(14)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) startek(260) products(1) m828Series(1) m828Hubs(1) m828HubTable(2) m828HubTableEntry(1) m828HubRoFTolState(14)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) startek(260) products(1) m828Series(1) m828Hubs(1) m828HubTable(2) m828HubTableEntry(1) m828HubRoFTolState(14)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) startek(260) products(1) m828Series(1) m828Hubs(1) m828HubTable(2) m828HubTableEntry(1) m828HubRoFTolState(14)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/startek/products/m828Series/m828Hubs/m828HubTable/m828HubTableEntry/m828HubRoFTolState
  • /iso/identified-organization/dod/internet/private/enterprises/startek/products/m828Series/m828Hubs/m828HubTable/m828HubTableEntry/m828HubRoFTolState
  • /iso/org/dod/internet/private/enterprise/startek/products/m828Series/m828Hubs/m828HubTable/m828HubTableEntry/m828HubRoFTolState
  • /iso/org/dod/internet/private/enterprises/startek/products/m828Series/m828Hubs/m828HubTable/m828HubTableEntry/m828HubRoFTolState
  • /iso/iso-identified-organization/dod/internet/private/enterprise/startek/products/m828Series/m828Hubs/m828HubTable/m828HubTableEntry/m828HubRoFTolState
  • /iso/iso-identified-organization/dod/internet/private/enterprises/startek/products/m828Series/m828Hubs/m828HubTable/m828HubTableEntry/m828HubRoFTolState
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/260/1/1/1/2/1/14

    Description by mibdepot

    This parameter controls the Ring Out(RO) fault tolerance
    behavior. The default value for this parameter is the
    same setting as is present for m828HubRoFTolSw. SETTING
    this parameter overrides the value derived from
    m828HubRoFTolSw. Off(1) means that phantom currentis not
    used on the corresponding RO interface as a condition for
    main ring link insertion. On (2) means that phantom
    current is used on the corresponding RO interface as a
    condition for main ring link insertion. The preffered
    setting for this parameter is on (2).

    Parsed from file startek.mib.txt
    Company: None
    Module: STARTEK-PRIVATE-MIB

    Description by circitor

    This parameter controls the Ring Out(RO) fault tolerance
    behavior. The default value for this parameter is the
    same setting as is present for m828HubRoFTolSw. SETTING
    this parameter overrides the value derived from
    m828HubRoFTolSw. Off(1) means that phantom currentis not
    used on the corresponding RO interface as a condition for
    main ring link insertion. On (2) means that phantom
    current is used on the corresponding RO interface as a
    condition for main ring link insertion. The preffered
    setting for this parameter is on (2).

    Parsed from file STARTEK-PRIVATE-MIB.mib
    Module: STARTEK-PRIVATE-MIB

    Information by oid_info

    Vendor: 3Com
    Module: STARTEK-PRIVATE-MIB (startek.mib)
    Type: TABULAR
    Access: read-write
    Syntax: INTEGER

    Automatically extracted from www.mibdepot.com

    Information by mibdepot

    m828HubRoFTolState OBJECT-TYPE SYNTAX INTEGER { off(1), on(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This parameter controls the Ring Out(RO) fault tolerance behavior. The default value for this parameter is the same setting as is present for m828HubRoFTolSw. SETTING this parameter overrides the value derived from m828HubRoFTolSw. Off(1) means that phantom currentis not used on the corresponding RO interface as a condition for main ring link insertion. On (2) means that phantom current is used on the corresponding RO interface as a condition for main ring link insertion. The preffered setting for this parameter is on (2)." ::= { m828HubTableEntry 14 }

    Information by circitor

    m828HubRoFTolState OBJECT-TYPE SYNTAX INTEGER { off(1), on(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This parameter controls the Ring Out(RO) fault tolerance behavior. The default value for this parameter is the same setting as is present for m828HubRoFTolSw. SETTING this parameter overrides the value derived from m828HubRoFTolSw. Off(1) means that phantom currentis not used on the corresponding RO interface as a condition for main ring link insertion. On (2) means that phantom current is used on the corresponding RO interface as a condition for main ring link insertion. The preffered setting for this parameter is on (2)." ::= { m828HubTableEntry 14 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.260)

    Madison Carl

    Brothers (27)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.260.1.1.1.2.1.1 m828HubTableIndex 0 0 The index for this hub entry.
    1.3.6.1.4.1.260.1.1.1.2.1.2 m828HubModel 0 0 The model number of the m828 series hub being managed.
    1.3.6.1.4.1.260.1.1.1.2.1.3 m828Hub485Address 0 0 The 4 hex digit address used on the RS485 serial OOB
    management channel.
    1.3.6.1.4.1.260.1.1.1.2.1.4 m828HubRiFTolSw 0 0 The status of the Ring In fault tolerance switch on the
    front panel of the hub.
    1.3.6.1.4.1.260.1.1.1.2.1.5 m828HubRiFTolState 0 0 This parameter controls the Ring In (RI) fault tolerance
    behavior. The default value for this parameter is the
    same setting as is…
    1.3.6.1.4.1.260.1.1.1.2.1.6 m828HubRiMask 0 0 Administrative status for this Ring In port. By
    setting this parameter, a remote manager can control
    the partitioning of this por…
    1.3.6.1.4.1.260.1.1.1.2.1.7 m828HubRiPhDet 0 0 This parameter describes the phantom detect status for
    this Ring In port.
    1.3.6.1.4.1.260.1.1.1.2.1.8 m828HubRiNsrtStatus 0 0 Insertion status for this Ring In port.
    1.3.6.1.4.1.260.1.1.1.2.1.9 m828HubRiBcnRemStatus 0 0 This parameter describes the result of any automatic
    beacon removal operations performed by the agent on this
    port. Automatic bea…
    1.3.6.1.4.1.260.1.1.1.2.1.10 m828RiNeighborType 0 0 This parameter indicates the type of nearest neighbor
    on the Ring In port.
    1.3.6.1.4.1.260.1.1.1.2.1.11 m828RiNeighborAddr 0 0 The address of the nearest neighbor on the Ring In port.
    1.3.6.1.4.1.260.1.1.1.2.1.12 m828RiTimeStamp 0 0 The time the status of Ring In (was) last changed.
    1.3.6.1.4.1.260.1.1.1.2.1.13 m828HubRoFTolSw 0 0 The state of the Ring Out Fault Tolerance switch on
    the front panel of the unit.
    1.3.6.1.4.1.260.1.1.1.2.1.15 m828HubRoMask 0 0 Administrative status for this Ring Out port. By
    setting this parameter, a remote manager can control
    the partitioning of this po…
    1.3.6.1.4.1.260.1.1.1.2.1.16 m828HubRoPhDet 0 0 This parameter describes the phantom detect status for
    this Ring Out port.
    1.3.6.1.4.1.260.1.1.1.2.1.17 m828HubRoNsrtStatus 0 0 Insertion status for this Ring Out port.
    1.3.6.1.4.1.260.1.1.1.2.1.18 m828HubRoBcnRemStatus 0 0 This parameter describes the result of any automatic
    beacon removal operations performed by the agent on this
    port. Automatic bea…
    1.3.6.1.4.1.260.1.1.1.2.1.19 m828RoNeighborType 0 0 This parameter indicates the type of nearest neighbor
    on the Ring Out port.
    1.3.6.1.4.1.260.1.1.1.2.1.20 m828RoNeighborAddr 0 0 The address of the nearest neighbor on the Ring Out
    port.
    1.3.6.1.4.1.260.1.1.1.2.1.21 m828RoTimeStamp 0 0 The time the status of Ring Out (was) last changed.
    1.3.6.1.4.1.260.1.1.1.2.1.22 m828HubDataRateSwitch 0 0 Setting of this parameter changes the data rate of
    this unit. A value of noSwitch(3) indicates that the
    setting of the data rate…
    1.3.6.1.4.1.260.1.1.1.2.1.23 m828HubDataRateState 0 0 This parameter indicates the current data rate of
    this unit.
    1.3.6.1.4.1.260.1.1.1.2.1.24 m828HubDataRateTimeStamp 0 0 The time the data rate status (was) last changed.
    1.3.6.1.4.1.260.1.1.1.2.1.25 m828HubMgmtStatus 0 0 The operational status of this unit.
    1.3.6.1.4.1.260.1.1.1.2.1.26 m828HubProxyAgentID 0 0 The physical layer MAC Address of the agent.
    1.3.6.1.4.1.260.1.1.1.2.1.27 m828HubCodeVersion 0 0 The firmware version number of this unit.
    1.3.6.1.4.1.260.1.1.1.2.1.28 m828HubRawCommandData 0 0 This is used to send raw 485 serial data to
    this unit.