Actual message status
1: not available
2: configuration has changed (sensor new, changed, lost)
3: error
4: OK
5: alarm, e.g. smoke, vibration...
6: warning of analog value, value reached warning threshold
7: analog value too low, value reached low threshold
8: analog value too high, value reached high threshold
9: output is set to ON
10: output is set to OFF
11: door is open
12: door is closed
13: door is locked
14: door is unlocked by remote input, e.g. external cardreader
15: door is unlocked by reader or keypad connected to I2C
16: door is unlocked by SNMP set command (unit1OutputSet)
17: door is unlocked by WEB
18: door is unlocked by timer
19: no access, wrong keycode or cardnumber
Parsed from file CMC-TC.mib.txt
Company: None
Module: RITTAL-CMC-TC-MIB
Actual message status
1: not available
2: configuration has changed (sensor new, changed, lost)
3: error
4: OK
5: alarm, e.g. smoke, vibration...
6: warning of analog value, value reached warning threshold
7: analog value too low, value reached low threshold
8: analog value too high, value reached high threshold
9: output is set to ON
10: output is set to OFF
11: door is open
12: door is closed
13: door is locked
14: door is unlocked by remote input, e.g. external cardreader
15: door is unlocked by reader or keypad connected to I2C
16: door is unlocked by SNMP set command (unit1OutputSet)
17: door is unlocked by WEB
18: door is unlocked by timer
19: no access, wrong keycode or cardnumber
Parsed from file RITTAL-CMC-TC-MIB.mib
Module: RITTAL-CMC-TC-MIB
Vendor: Rittal-Werk Rudolf Loh GmbH & Co.KG
Module: RITTAL-CMC-TC-MIB
[Automatically extracted from oidview.com]
unit4MsgStatus OBJECT-TYPE SYNTAX INTEGER { notAvail(1), configChanged(2), error(3), ok(4), alarm(5), warning(6), tooLow(7), tooHigh(8), setOff(9), setOn(10), open(11), closed(12), locked(13), unlRemote(14), unlReaderKeypad(15), unlSNMP(16), unlWEB(17), unlTimer(18), noAccess(19) } ACCESS read-only STATUS mandatory DESCRIPTION "Actual message status 1: not available 2: configuration has changed (sensor new, changed, lost) 3: error 4: OK 5: alarm, e.g. smoke, vibration... 6: warning of analog value, value reached warning threshold 7: analog value too low, value reached low threshold 8: analog value too high, value reached high threshold 9: output is set to ON 10: output is set to OFF 11: door is open 12: door is closed 13: door is locked 14: door is unlocked by remote input, e.g. external cardreader 15: door is unlocked by reader or keypad connected to I2C 16: door is unlocked by SNMP set command (unit1OutputSet) 17: door is unlocked by WEB 18: door is unlocked by timer 19: no access, wrong keycode or cardnumber" ::= { cmcTcUnit4MsgEntry 3 }
unit4MsgStatus OBJECT-TYPE SYNTAX INTEGER { notAvail(1), configChanged(2), error(3), ok(4), alarm(5), warning(6), tooLow(7), tooHigh(8), setOff(9), setOn(10), open(11), closed(12), locked(13), unlRemote(14), unlReaderKeypad(15), unlSNMP(16), unlWEB(17), unlTimer(18), noAccess(19) } ACCESS read-only STATUS mandatory DESCRIPTION "Actual message status 1: not available 2: configuration has changed (sensor new, changed, lost) 3: error 4: OK 5: alarm, e.g. smoke, vibration... 6: warning of analog value, value reached warning threshold 7: analog value too low, value reached low threshold 8: analog value too high, value reached high threshold 9: output is set to ON 10: output is set to OFF 11: door is open 12: door is closed 13: door is locked 14: door is unlocked by remote input, e.g. external cardreader 15: door is unlocked by reader or keypad connected to I2C 16: door is unlocked by SNMP set command (unit1OutputSet) 17: door is unlocked by WEB 18: door is unlocked by timer 19: no access, wrong keycode or cardnumber" ::= { cmcTcUnit4MsgEntry 3 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.2606.4.2.6.7.2.1.1 | unit4MsgIndex | 0 | 0 | Index for the list of alarm entries. Its value ranges between 1 and the value of cmcTcUnit4NumberOfMsgs. |
1.3.6.1.4.1.2606.4.2.6.7.2.1.2 | unit4MsgText | 0 | 0 | Descriptional text for each message (entry in the table) |
1.3.6.1.4.1.2606.4.2.6.7.2.1.4 | unit4MsgRelay | 0 | 0 | Setup of Alarm relay for this alarm 1: no switching of alarm relay 2: switching of alarm relay |
1.3.6.1.4.1.2606.4.2.6.7.2.1.5 | unit4MsgBeeper | 0 | 0 | Setup of Alarm beeper for this alarm 1: no audible alarm 2: audible alarm |
1.3.6.1.4.1.2606.4.2.6.7.2.1.6 | unit4MsgTrap1 | 0 | 0 | Trap receiver 1 activated |
1.3.6.1.4.1.2606.4.2.6.7.2.1.7 | unit4MsgTrap2 | 0 | 0 | Trap receiver 2 activated |
1.3.6.1.4.1.2606.4.2.6.7.2.1.8 | unit4MsgTrap3 | 0 | 0 | Trap receiver 3 activated |
1.3.6.1.4.1.2606.4.2.6.7.2.1.9 | unit4MsgTrap4 | 0 | 0 | Trap receiver 4 and Event Logging activated |
1.3.6.1.4.1.2606.4.2.6.7.2.1.10 | unit4MsgQuit | 0 | 0 | Reset of this alarm 1: auto 2: manual, alarm needs confirmation, e. g. with 'C' key |