No description available
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.2620.1.6.7.8.3.1.1
No description available
Identification
{1 3 6 1 4 1 2620 1 6 7 8 3 1 1}
Definitions may combine these properties differently.
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.
In CHECKPOINT-MIB, the row index voltageSensorIndex is declared as INTEGER. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.2620.1.6.7.8.3.1.1.<voltageSensorIndex>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.
A query example is omitted because the source variants do not establish compatible read access.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 3 distinct definitions; some records may not include a definition.
voltageSensorIndex OBJECT-TYPE
SYNTAX INTEGER (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION ""
::= { voltageSensorEntry 1 }voltageSensorIndex OBJECT-TYPE
SYNTAX Integer32 (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "No description available"
::= { voltageSensorEntry 1 }voltageSensorIndex OBJECT-TYPE
SYNTAX Integer32 (0..100)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "No description available"
::= { voltageSensorEntry 1 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
No description available
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: voltageSensorIndex
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"voltageSensorIndex",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"(",
"0",
".",
".",
"100",
")",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"\"",
"::=",
"{",
"voltageSensorEntry",
"1",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"integerSubType",
[
[
0,
100
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
""
],
null,
null,
null,
null
]
}Vendor MIB copy from the Netdisco archive.
Module: CHECKPOINT-MIB
See published definition above
{'SNMPv2-TC': ['DisplayString'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'Unsigned32', 'IpAddress', 'Counter32', 'NOTIFICATION-TYPE', 'enterprises'], 'SNMPv2-CONF': ['OBJECT-GROUP']}Related source files and packages:
Status in source: current.
Names: voltageSensorIndex
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"voltageSensorIndex",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"(",
"0",
".",
".",
"100",
")",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"No description available\"",
"::=",
"{",
"voltageSensorEntry",
"1",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32",
[
"integerSubType",
[
[
0,
100
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"No description available"
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: CHECKPOINT-MIB
See published definition above
{'SNMPv2-TC': ['DisplayString'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'Unsigned32', 'IpAddress', 'Counter32', 'Counter64', 'Gauge32', 'NOTIFICATION-TYPE', 'enterprises'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP']}Related source files and packages:
Status in source: current.
Names: voltageSensorIndex
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"voltageSensorIndex",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"(",
"0",
".",
".",
"100",
")",
"MAX-ACCESS",
"not-accessible",
"STATUS",
"current",
"DESCRIPTION",
"\"No description available\"",
"::=",
"{",
"voltageSensorEntry",
"1",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32",
[
"integerSubType",
[
[
0,
100
]
]
]
],
null,
[
"MaxAccessPart",
"not-accessible"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"No description available"
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: CHECKPOINT-MIB
See published definition above
{'SNMPv2-TC': ['DisplayString'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'Unsigned32', 'IpAddress', 'Counter32', 'Counter64', 'Gauge32', 'enterprises'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP']}Related source files and packages:
Historical records
Source file: Download chkpnt.mib.txt
Source data warning: Some published OBJECT-TYPE value names start with uppercase letters outside SMI identifier syntax. Exact names, references, numeric OIDs and original definitions are preserved.
Browse all files from MIBdepot
voltageSensorIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
::= { voltageSensorEntry 1 }
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.2620.1.6.7.8.3.1.2 | voltageSensorName | 0 | 0 | Sensor name |
| 1.3.6.1.4.1.2620.1.6.7.8.3.1.3 | voltageSensorValue | 0 | 0 | Sensor value |
| 1.3.6.1.4.1.2620.1.6.7.8.3.1.4 | voltageSensorUnit | 0 | 0 | Sensor unit |
| 1.3.6.1.4.1.2620.1.6.7.8.3.1.5 | voltageSensorType | 0 | 0 | Sensor type |
| 1.3.6.1.4.1.2620.1.6.7.8.3.1.6 | voltageSensorStatus | 0 | 0 | Sensor is out of range TRUE(1), FALSE(0), READING ERROR(2) |