The actual trace identifier accepted. This object is applicable only to the following three cases. (i) jnxoptIfODUkDirectionality has the value bidirectional(3), or (ii) jnxoptIfODUkDirectionality has the value sink(1) and jnxoptIfODUkTCodirectional has the value true(1), or (iii) jnxoptIfODUkDirectionality has the value source(3) and jnxoptIfODUkTCodirectional has the value false(2). It must not be instantiated in rows for all other cases. The value of this object is unspecified when jnxoptIfODUkTCurrentStatus indicates a near-end defect (i.e., oci(0), lck(1), ssf(5)) that prevents extraction of the trace message.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Juniper official MIBsNetdisco MIB archive copies