Provides the capability to provision the LOCK signal, which is one of the ODUk maintenance signals, at the ODUKT sink. When a Tandem Connection endpoint is set to admin state locked, it inserts the ODUk-LCK signal in the sink direction. This object is applicable only when the value of jnxoptIfODUkTtpPresent is false(2) and also either one of the following three cases holds: (i) jnxoptIfODUkDirectionality has the value bidirectional(3), or (ii) jnxoptIfODUkDirectionality has the value sink(1) and jnxoptIfODUkTCodirectional has the value true(1), or (iii) jnxoptIfODUkDirectionality has the value source(3) and jnxoptIfODUkTCodirectional has the value false(2). It must not be instantiated in rows for all other cases.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Juniper official MIBsNetdisco MIB archive copies