Fan sensor number
Sources for this description
FS.COM official Documentation Hub native MIB packages
OID reference
1.3.6.1.4.1.27975.37.4.1.1
Fan sensor number
Identification
{1 3 6 1 4 1 27975 37 4 1 1}
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.
In CENTEC, the row index devMTemperatureIndex is declared as Integer32. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.27975.37.4.1.1.<devMTemperatureIndex>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.
Published row index: devMTemperatureIndex.
A query example is omitted because the source variants do not establish compatible read access.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Product context
The FS.COM catalogue lists MIB packages containing this definition for these models:
A definition in a model's MIB package does not establish that the device implements it or permits access.
The displayed source records contain one distinct definition. Compare its source records.
devMTemperatureIndex OBJECT-TYPE
SYNTAX Integer32 (1..16)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Fan sensor number"
::= { devMTemperatureEntry 1 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Fan sensor number
FS.COM official Documentation Hub native MIB packages
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: devMTemperatureIndex
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"devMTemperatureIndex",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"(",
"1",
".",
".",
"16",
")",
"MAX-ACCESS",
"not-accessible",
"STATUS",
"current",
"DESCRIPTION",
"\"Fan sensor number\"",
"::=",
"{",
"devMTemperatureEntry",
"1",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32",
[
"integerSubType",
[
[
1,
16
]
]
]
],
null,
[
"MaxAccessPart",
"not-accessible"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Fan sensor number"
],
null,
null,
null,
null
]
}Module: CENTEC
See published definition above
{'IF-MIB': ['ifIndex', 'InterfaceIndex', 'InterfaceIndexOrZero', 'ifIndex'], 'RMON-MIB': ['OwnerString'], 'VRRP-MIB': ['VrId'], 'SNMPv2-TC': ['TestAndIncr', 'TimeStamp', 'AutonomousType', 'PhysAddress', 'TEXTUAL-CONVENTION', 'TruthValue', 'DateAndTime', 'MacAddress', 'RowStatus'], 'SNMPv2-SMI': ['TimeTicks', 'Counter32', 'OBJECT-IDENTITY', 'mib-2', 'MODULE-IDENTITY', 'IpAddress', 'Counter64', 'Unsigned32', 'Integer32', 'Gauge32', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises'], 'SNMPv2-CONF': ['NOTIFICATION-GROUP', 'MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'INET-ADDRESS-MIB': ['InetAddressPrefixLength', 'InetAddress', 'InetAddressType'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.27975.37.4.1.2 | devMTemperatureValue | 0 | 0 | |
| 1.3.6.1.4.1.27975.37.4.1.3 | devMTemperatureLow | 0 | 0 | |
| 1.3.6.1.4.1.27975.37.4.1.4 | devMTemperatureHigh | 0 | 0 | |
| 1.3.6.1.4.1.27975.37.4.1.5 | devMTemperatureCritical | 0 | 0 | |
| 1.3.6.1.4.1.27975.37.4.1.6 | devMTemperatureLocation | 0 | 0 |