Status in source: current.
Names: fsElpsPgConfigWorkingServicePointer
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"fsElpsPgConfigWorkingServicePointer",
"OBJECT-TYPE",
"SYNTAX",
"RowPointer",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"This object is applicable for 'mplsLSP' and 'mplsPw' service types. When fsElpsPgConfigServiceType is 'mplsLSP' : - This object should be configured with the object identifier of the row in the MPLS tunnel table corresponding to the LSP being protected (working LSP). - In case of co-routed MPLS LSP, this object indicates the co-routed (forward and reverse) path of the LSP. In case of associated MPLS LSP, this object indicates the forward path of the LSP being protected. When fsElpsPgConfigServiceType is 'mplsPw' : - This object should be configured with the object identifier of the row in the MPLS Pseudo wire table corresponding to the PW being protected (working PW). This object is applicable only when the fsElpsPgConfigType object is configured as 'individual' type. When the fsElpsPgConfigType object is configured as 'list', this object will return a value of '0' and any attempt to configure this object to any value will throw an error.\"",
"::=",
"{",
"fsElpsPgConfigEntry",
"14",
"}"
],
"syntax_tree": [
[
"row",
"RowPointer"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This object is applicable for 'mplsLSP' and 'mplsPw' service types. When fsElpsPgConfigServiceType is 'mplsLSP' : - This object should be configured with the object identifier of the row in the MPLS tunnel table corresponding to the LSP being protected (working LSP). - In case of co-routed MPLS LSP, this object indicates the co-routed (forward and reverse) path of the LSP. In case of associated MPLS LSP, this object indicates the forward path of the LSP being protected. When fsElpsPgConfigServiceType is 'mplsPw' : - This object should be configured with the object identifier of the row in the MPLS Pseudo wire table corresponding to the PW being protected (working PW). This object is applicable only when the fsElpsPgConfigType object is configured as 'individual' type. When the fsElpsPgConfigType object is configured as 'list', this object will return a value of '0' and any attempt to configure this object to any value will throw an error."
],
null,
null,
null,
null
]
}
- Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
· Publisher's source file: Source package: observium-community-latest.tar.gz
Vendor MIB copy from the Observium Community archive.
Module: ARICENT-ELPS-MIB
See published definition above
Module imports
{'IF-MIB': ['InterfaceIndex', 'InterfaceIndexOrZero'], 'SNMPv2-TC': ['RowStatus', 'RowPointer', 'TruthValue', 'DisplayString', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'MODULE-IDENTITY', 'enterprises', 'Unsigned32', 'Counter32', 'NOTIFICATION-TYPE'], 'IEEE8021-CFM-MIB': ['Dot1agCfmMepId']}
· Download ARICENT-ELPS-MIB
Related source files and packages:
- Belden, GarrettCom and Hirschmann IT official standalone MIBs
· Publisher's source file: fselps.mib
Module: ARICENT-ELPS-MIB
Same published definition
Module imports
{'IF-MIB': ['InterfaceIndex', 'InterfaceIndexOrZero'], 'ECFM-MIB': ['Dot1agCfmMepId'], 'SNMPv2-TC': ['RowStatus', 'RowPointer', 'TruthValue', 'DisplayString', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'MODULE-IDENTITY', 'enterprises', 'Unsigned32', 'Counter32', 'NOTIFICATION-TYPE']}
· Download fselps.mib
Related source files and packages: