Status in source: current.
Names: fsElpsPgConfigProtectionReverseServicePointer
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"fsElpsPgConfigProtectionReverseServicePointer",
"OBJECT-TYPE",
"SYNTAX",
"RowPointer",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"This object is applicable for 'mplsLSP' service type only. When fsElpsPgConfigServiceType is 'mplsLSP' : - Configuring this object is optional. - This object should be configured with the object identifier of the row in the MPLS tunnel table, for the reverse path of the protecting LSP, corresponding to the working LSP. - This configuration is required only in case of associated MPLS LSP configured to protect the working LSP. - In case of co-routed mpls LSP, this object is not applicable. This object is applicable only when the fsElpsPgConfigType object is configured as 'individual' type. When the fsElpsPgConfigType object is configured as 'list', this object will return a value of '0' and any attempt to configure this object to any value will throw an error.\"",
"::=",
"{",
"fsElpsPgConfigEntry",
"17",
"}"
],
"syntax_tree": [
[
"row",
"RowPointer"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This object is applicable for 'mplsLSP' service type only. When fsElpsPgConfigServiceType is 'mplsLSP' : - Configuring this object is optional. - This object should be configured with the object identifier of the row in the MPLS tunnel table, for the reverse path of the protecting LSP, corresponding to the working LSP. - This configuration is required only in case of associated MPLS LSP configured to protect the working LSP. - In case of co-routed mpls LSP, this object is not applicable. This object is applicable only when the fsElpsPgConfigType object is configured as 'individual' type. When the fsElpsPgConfigType object is configured as 'list', this object will return a value of '0' and any attempt to configure this object to any value will throw an error."
],
null,
null,
null,
null
]
}
- Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
· Publisher's source file: Source package: observium-community-latest.tar.gz
Vendor MIB copy from the Observium Community archive.
Module: ARICENT-ELPS-MIB
See published definition above
Module imports
{'IF-MIB': ['InterfaceIndex', 'InterfaceIndexOrZero'], 'SNMPv2-TC': ['RowStatus', 'RowPointer', 'TruthValue', 'DisplayString', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'MODULE-IDENTITY', 'enterprises', 'Unsigned32', 'Counter32', 'NOTIFICATION-TYPE'], 'IEEE8021-CFM-MIB': ['Dot1agCfmMepId']}
· Download ARICENT-ELPS-MIB
Related source files and packages:
- Belden, GarrettCom and Hirschmann IT official standalone MIBs
· Publisher's source file: fselps.mib
Module: ARICENT-ELPS-MIB
Same published definition
Module imports
{'IF-MIB': ['InterfaceIndex', 'InterfaceIndexOrZero'], 'ECFM-MIB': ['Dot1agCfmMepId'], 'SNMPv2-TC': ['RowStatus', 'RowPointer', 'TruthValue', 'DisplayString', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'MODULE-IDENTITY', 'enterprises', 'Unsigned32', 'Counter32', 'NOTIFICATION-TYPE']}
· Download fselps.mib
Related source files and packages: