| 1.3.6.1.4.1.29640.4.3.33.1.1 |
nodeIndex | 0 | 0 |
The node table Index. |
| 1.3.6.1.4.1.29640.4.3.33.1.2 |
nodeType | 0 | 0 |
Type of the node. TypeUnknown (0) Unknown node. TypePresModChar (1) PM LCD Character Module. TypePresModMono (2) PM Mono Graphi… |
| 1.3.6.1.4.1.29640.4.3.33.1.3 |
nodeOutlet | 0 | 0 |
The number associated with the physical outlet of the node. The special value of 0 indicates that this entry is not associated … |
| 1.3.6.1.4.1.29640.4.3.33.1.4 |
nodeAlarmStatus | 0 | 0 |
Array of bits each one indicates an alarm activated in the alarm selector value. TrapCurrHi (0) The current is to high against … |
| 1.3.6.1.4.1.29640.4.3.33.1.5 |
nodePower | 0 | 0 |
The measured node power in Kilo Watt\s*Hour. |
| 1.3.6.1.4.1.29640.4.3.33.1.6 |
nodeAcurrent | 0 | 0 |
The measured ac current at the node (in 1/10th Amperes). |
| 1.3.6.1.4.1.29640.4.3.33.1.7 |
nodePeakCurrent | 0 | 0 |
The measured max current since last reset of the node (in 1/10th Amperes). |
| 1.3.6.1.4.1.29640.4.3.33.1.8 |
nodeVoltage | 0 | 0 |
The measured voltage on the node. |
| 1.3.6.1.4.1.29640.4.3.33.1.9 |
nodeMinVoltage | 0 | 0 |
The measured minimum voltage at the node since last reset. |
| 1.3.6.1.4.1.29640.4.3.33.1.10 |
nodeKvar | 0 | 0 |
The Reactive Power. It is the power that magnetic equipment (transformer, motor and relay) needs to produce the magnetizing flu… |
| 1.3.6.1.4.1.29640.4.3.33.1.11 |
nodeFrequency | 0 | 0 |
The frequency of alternating current in Hertz. e.g 50 in Europe or 60 in USA. |
| 1.3.6.1.4.1.29640.4.3.33.1.12 |
nodePowerFactor | 0 | 0 |
The effective power facton (Cosinus Phi) in percents of the node. |
| 1.3.6.1.4.1.29640.4.3.33.1.13 |
nodeSwitchOperStatus | 0 | 0 |
The actual operational Status of the node. Unknown (0) not known status. Off (1) switch is off. On (2) switch is on. |
| 1.3.6.1.4.1.29640.4.3.33.1.14 |
nodeSwitchAdminStatus | 0 | 0 |
The desired admin Status of the switch. Unknown (0) not known. Off (1) switch is off. On (2) switch is on. |
| 1.3.6.1.4.1.29640.4.3.33.1.15 |
nodeCurrHiThresh | 0 | 0 |
The current high threshold (in 1/10th Amperes). |
| 1.3.6.1.4.1.29640.4.3.33.1.16 |
nodeCurrLoThresh | 0 | 0 |
The current low threshold (in 1/10th Amperes). |
| 1.3.6.1.4.1.29640.4.3.33.1.17 |
nodeVoltHiThresh | 0 | 0 |
The voltage high threshold. |
| 1.3.6.1.4.1.29640.4.3.33.1.18 |
nodeVoltLoThresh | 0 | 0 |
The voltage low threshold. |
| 1.3.6.1.4.1.29640.4.3.33.1.19 |
nodeAlarmSelector | 0 | 0 |
Array of bits each one controls one alarm. TrapCurrHi (0) Enable/disable the high current alarm. TrapCurrLo (1) Enable/disable … |
| 1.3.6.1.4.1.29640.4.3.33.1.20 |
nodeName | 0 | 0 |
The node name. My be set by manager. |
| 1.3.6.1.4.1.29640.4.3.33.1.21 |
nodePhase | 0 | 0 |
The measured phase of the node. Maybe assigned when not configured in production. PhaseUnknown (0). PhaseL1 (1). PhaseL2 (2). P… |