Description 1
Original text from OID Repository
SYNTAX Unsigned32
UNITS "kiloWattHours"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The measured node power in Kilo Watt\s*Hour."
OID reference
1.3.6.1.4.1.29640.4.3.33.1.5
The measured node power in Kilo Watt\s*Hour.
Identification
{1 3 6 1 4 1 29640 4 3 33 1 5}
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition. The index encoding is not inferred here.
Published row index: nodeIndex.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.29640.4.3.33.1.5
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
nodePower OBJECT-TYPE
SYNTAX Unsigned32
UNITS "kiloWattHours"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The measured node power in Kilo Watt's*Hour."
::= { nodeEntry 5 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Description 1
Description 2
The measured node power in Kilo Watt's*Hour.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: nodePower
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"nodePower",
"OBJECT-TYPE",
"SYNTAX",
"Unsigned32",
"UNITS",
[
"literal",
"226b696c6f57617474486f75727322"
],
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"The measured node power in Kilo Watt's*Hour.\"",
"::=",
"{",
"nodeEntry",
"5",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Unsigned32"
],
[
"UNITS",
"kiloWattHours"
],
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The measured node power in Kilo Watt's*Hour."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: APNL-MODULAR-PDU-MIB
See published definition above
{'SNMPv2-TC': ['DateAndTime', 'DisplayString'], 'SNMPv2-SMI': ['NOTIFICATION-TYPE', 'OBJECT-TYPE', 'MODULE-IDENTITY', 'enterprises', 'IpAddress', 'Unsigned32', 'Integer32']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.29640.4.3.33.1.1 | nodeIndex | 0 | 0 | The node table Index. |
| 1.3.6.1.4.1.29640.4.3.33.1.2 | nodeType | 0 | 0 | Type of the node. TypeUnknown (0) Unknown node. TypePresModChar (1) PM LCD Character Module. TypePresModMono (2) PM Mono Graphi… |
| 1.3.6.1.4.1.29640.4.3.33.1.3 | nodeOutlet | 0 | 0 | The number associated with the physical outlet of the node. The special value of 0 indicates that this entry is not associated … |
| 1.3.6.1.4.1.29640.4.3.33.1.4 | nodeAlarmStatus | 0 | 0 | Array of bits each one indicates an alarm activated in the alarm selector value. TrapCurrHi (0) The current is to high against … |
| 1.3.6.1.4.1.29640.4.3.33.1.6 | nodeAcurrent | 0 | 0 | The measured ac current at the node (in 1/10th Amperes). |
| 1.3.6.1.4.1.29640.4.3.33.1.7 | nodePeakCurrent | 0 | 0 | The measured max current since last reset of the node (in 1/10th Amperes). |
| 1.3.6.1.4.1.29640.4.3.33.1.8 | nodeVoltage | 0 | 0 | The measured voltage on the node. |
| 1.3.6.1.4.1.29640.4.3.33.1.9 | nodeMinVoltage | 0 | 0 | The measured minimum voltage at the node since last reset. |
| 1.3.6.1.4.1.29640.4.3.33.1.10 | nodeKvar | 0 | 0 | The Reactive Power. It is the power that magnetic equipment (transformer, motor and relay) needs to produce the magnetizing flu… |
| 1.3.6.1.4.1.29640.4.3.33.1.11 | nodeFrequency | 0 | 0 | The frequency of alternating current in Hertz. e.g 50 in Europe or 60 in USA. |
| 1.3.6.1.4.1.29640.4.3.33.1.12 | nodePowerFactor | 0 | 0 | The effective power facton (Cosinus Phi) in percents of the node. |
| 1.3.6.1.4.1.29640.4.3.33.1.13 | nodeSwitchOperStatus | 0 | 0 | The actual operational Status of the node. Unknown (0) not known status. Off (1) switch is off. On (2) switch is on. |
| 1.3.6.1.4.1.29640.4.3.33.1.14 | nodeSwitchAdminStatus | 0 | 0 | The desired admin Status of the switch. Unknown (0) not known. Off (1) switch is off. On (2) switch is on. |
| 1.3.6.1.4.1.29640.4.3.33.1.15 | nodeCurrHiThresh | 0 | 0 | The current high threshold (in 1/10th Amperes). |
| 1.3.6.1.4.1.29640.4.3.33.1.16 | nodeCurrLoThresh | 0 | 0 | The current low threshold (in 1/10th Amperes). |
| 1.3.6.1.4.1.29640.4.3.33.1.17 | nodeVoltHiThresh | 0 | 0 | The voltage high threshold. |
| 1.3.6.1.4.1.29640.4.3.33.1.18 | nodeVoltLoThresh | 0 | 0 | The voltage low threshold. |
| 1.3.6.1.4.1.29640.4.3.33.1.19 | nodeAlarmSelector | 0 | 0 | Array of bits each one controls one alarm. TrapCurrHi (0) Enable/disable the high current alarm. TrapCurrLo (1) Enable/disable … |
| 1.3.6.1.4.1.29640.4.3.33.1.20 | nodeName | 0 | 0 | The node name. My be set by manager. |
| 1.3.6.1.4.1.29640.4.3.33.1.21 | nodePhase | 0 | 0 | The measured phase of the node. Maybe assigned when not configured in production. PhaseUnknown (0). PhaseL1 (1). PhaseL2 (2). P… |