The defined values have the following description
Off - The unit is not equipped or is provision in an out of Service state
Green - No alarms, status or test conditions exists for the unit
Blink Amber
- Test conditions are present in the unit
Solid Amber
- A minor alarm condition persists in the unit or on some
interface of the unit, or the unit is powering up.
Red - An Alarm condition persists in the unit or on some interface of the unit
Blink-Green - reserved
Blink-Red - reserved
Parsed from file dl5400.mib.txt
Company: None
Module: DL5400-MIB
The defined values have the following description
Off - The unit is not equipped or is provision in an out of Service state
Green - No alarms, status or test conditions exists for the unit
Blink Amber
- Test conditions are present in the unit
Solid Amber
- A minor alarm condition persists in the unit or on some
interface of the unit, or the unit is powering up.
Red - An Alarm condition persists in the unit or on some interface of the unit
Blink-Green - reserved
Blink-Red - reserved
Parsed from file DL5400-MIB.mib
Module: DL5400-MIB
Vendor: Digital Link
Module: DL5400-MIB
[Automatically extracted from oidview.com]
unitLedStatus OBJECT-TYPE SYNTAX INTEGER { off (1), green (2), blink-Green (3), blink-Amber (4), solid-Amber (5), red (6), blink-Red (7) } ACCESS read-only STATUS mandatory DESCRIPTION " The defined values have the following description Off - The unit is not equipped or is provision in an out of Service state Green - No alarms, status or test conditions exists for the unit Blink Amber - Test conditions are present in the unit Solid Amber - A minor alarm condition persists in the unit or on some interface of the unit, or the unit is powering up. Red - An Alarm condition persists in the unit or on some interface of the unit Blink-Green - reserved Blink-Red - reserved " ::= { unitLevelConfig 14 }
unitLedStatus OBJECT-TYPE SYNTAX INTEGER { off (1), green (2), blink-Green (3), blink-Amber (4), solid-Amber (5), red (6), blink-Red (7) } ACCESS read-only STATUS mandatory DESCRIPTION " The defined values have the following description Off - The unit is not equipped or is provision in an out of Service state Green - No alarms, status or test conditions exists for the unit Blink Amber - Test conditions are present in the unit Solid Amber - A minor alarm condition persists in the unit or on some interface of the unit, or the unit is powering up. Red - An Alarm condition persists in the unit or on some interface of the unit Blink-Green - reserved Blink-Red - reserved " ::= { unitLevelConfig 14 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.300.110.1.1.14.0 | unitLedStatus | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.300.110.1.1.1 | unitSerialNum | 1 | 1 | An ID that uniquely and globally identifies the unit. A Serial Number must consist of printable ASCII characters 0x20..0x7E. |
1.3.6.1.4.1.300.110.1.1.2 | unitName | 1 | 1 | A descriptive name that identifies the DL5400 unit. Use of this parameter is optional, but recommended to aid management. |
1.3.6.1.4.1.300.110.1.1.3 | unitHwRev | 1 | 1 | The DL5400 hardware revision. |
1.3.6.1.4.1.300.110.1.1.4 | unitSwRev | 1 | 1 | The DL5400 software revision. |
1.3.6.1.4.1.300.110.1.1.5 | unitMibRev | 1 | 1 | The DL5400 MIB revision. |
1.3.6.1.4.1.300.110.1.1.6 | unitFrontPnl | 1 | 1 | This feature enables (ON) or disables (OFF) the users ability to make changes in the configuration or run tests from the front pa… |
1.3.6.1.4.1.300.110.1.1.7 | unitDateYear | 1 | 1 | The DL5400's date: Year. |
1.3.6.1.4.1.300.110.1.1.8 | unitDateMonth | 1 | 1 | The DL5400's date: Month. |
1.3.6.1.4.1.300.110.1.1.9 | unitDateDay | 1 | 1 | The DL5400's date: Day. |
1.3.6.1.4.1.300.110.1.1.10 | unitTimeHour | 1 | 1 | The DL5400's time: Hour. |
1.3.6.1.4.1.300.110.1.1.11 | unitTimeMinute | 1 | 1 | The DL5400's time: Minute. |
1.3.6.1.4.1.300.110.1.1.12 | unitTimeSecond | 1 | 1 | The DL5400's time: Second. |
1.3.6.1.4.1.300.110.1.1.13 | unitTimezone | 1 | 1 | This object is used to indicate the timezone associated with the time of day that exists on DL5400 System. The enumerated values … |
1.3.6.1.4.1.300.110.1.1.15 | unitTimeStamp | 1 | 1 | Time Stamp on the unit of format MM/DD/YYYY HH:MM:SS This will be sent as a varbind along with all the traps to NMS manager |
1.3.6.1.4.1.300.110.1.1.16 | unitModelType | 1 | 1 | The unit model type |
1.3.6.1.4.1.300.110.1.1.17 | unitRouteMode | 1 | 1 | Unit Route Mode |