MIB module for managing Asentria SiteBoss 571
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.3052.14
MIB module for managing Asentria SiteBoss 571
Identification
{1 3 6 1 4 1 3052 14}
Available source records contain 2 distinct definitions; some records may not include a definition.
s571 MODULE-IDENTITY
LAST-UPDATED "201412110143Z"
ORGANIZATION "Asentria Corporation"
CONTACT-INFO
"Phone: 206-344-8800
Fax: 206-344-2116
Email: support@asentria.com"
DESCRIPTION
"MIB module for managing Asentria SiteBoss 571"
REVISION "201412110143Z"
DESCRIPTION
"-v1.43
-Changed analog-input fuel sensor objects from Integer32 to DisplayString (OMX-1177).
-Added missing ipv6DefaultRouter object (OMX-1175).
-Applicable since unit version 2.10.580."
REVISION "201410160142Z"
DESCRIPTION
"-v1.42
-Added espcAIDisplayFormat object (OMX-1112).
-Removed espcAIPolarity, espcAIConvHighSign, espcAIConvLowSign objects (OMX-1113).
-Applicable since unit version 2.10.460."
REVISION "201410030141Z"
DESCRIPTION
"-v1.41
-Changed analog input objects from Integer32 to DisplayString.
-Applicable since unit version 2.10.460."
REVISION "201408140140Z"
DESCRIPTION
"-v1.40
-Fixed description for wirelessConnIP objects (OMX-1061).
-Applicable since unit version 2.10.390."
REVISION "201407030139Z"
DESCRIPTION
"-v1.39
-Fixed wirelessIdleTimeout (OMX-1037).
-Fixed CPE status objects (OMX-1036).
-Applicable since unit version 2.10.390."
REVISION "201406240138Z"
DESCRIPTION
"-v1.38
-Fixed CPE status objects.
-Applicable since unit version 2.10.340."
REVISION "201405290137Z"
DESCRIPTION
"-v1.37
-Added various missing objects (OMX-751).
-Added CPE objects (OMX-162).
-Applicable since unit version 2.10.320."
REVISION "201404110136Z"
DESCRIPTION
"-v1.36
-Clarified relay and power output function and documentation (OMX-926).
-Applicable since unit version 2.10.300."
REVISION "201401170135Z"
DESCRIPTION
"-v1.35
-Added IPv6 objects (OMX-705).
-Added power distribution objects (powerDistributionStatus branch) (OMX-708).
-Fixed ipRestrictionMask wrong type (OMX-743).
-Added ftpPushPermissions (OMX-737).
-Added snmpProxy objects (OMX-747).
-Applicable since unit version 2.10.150."
REVISION "201312040134Z"
DESCRIPTION
"-v1.34
-Added fsGenEnable (OMX-661).
-Applicable since unit version 2.10.110."
REVISION "201309040133Z"
DESCRIPTION
"-v1.33
-Added pdSystemCurrent and pdSystemPower objects (OMX-527).
-Added pdnDeviceCurrentValue and pdnDeviceCurrentValueStr objects (OMX-528).
-Applicable since unit version 2.09.626."
REVISION "201308010132Z"
DESCRIPTION
"-v1.32
-Added missing trapEventTypeNumber available values in description (OMX-437).
-Applicable since unit version 2.09.560."
REVISION "201307170131Z"
DESCRIPTION
"-v1.31
-Corrected snmpPBufferAllPeriod object.
-Applicable since unit version 2.09.560."
REVISION "201307020130Z"
DESCRIPTION
"-v1.30
-Added snmpPoll objects (OMX-394).
-Applicable since unit version 2.09.560."
REVISION "201306280129Z"
DESCRIPTION
"-v1.29
-Removed Ethernet Expansion card objects.
-Applicable since unit version 2.09.540."
REVISION "201306130128Z"
DESCRIPTION
"-v1.28
-Added sysFileTransfer and sysUpdate objects. (OMX-42)
-Applicable since unit version 2.09.520."
REVISION "201306120127Z"
DESCRIPTION
"-v1.27
-Renamed EX10 to Ethernet Expansion (OMX-364)
-Applicable since unit version 2.09.510."
REVISION "201305280126Z"
DESCRIPTION
"-v1.26
-Fixed incorrect SYNTAX for sysCharMask (OMX-328).
-Applicable since unit version 2.09.380."
REVISION "201305100125Z"
DESCRIPTION
"-v1.25
-Fixed incorrect SYNTAX statements for various objects (OMX-314).
-Applicable since unit version 2.09.380."
REVISION "201303150124Z"
DESCRIPTION
"-v1.24
-Renamed sysLocation branch to sysLoc (OMX-198).
-Applicable since unit version 2.09.240."
REVISION "201302060123Z"
DESCRIPTION
"-v1.23
-Added ex10 branch.
-Renamed telnet* objects.
-Applicable since unit version 2.09.240."
REVISION "201301140122Z"
DESCRIPTION
"-v1.22
-Added evReset branch and associated notification (OMX-83).
-Applicable since unit version 2.09.220."
REVISION "201211260121Z"
DESCRIPTION
"-v1.21
-Fixed backwards pppRoutingEnable/ethRoutingEnable comments. (BN 4620)"
REVISION "201208220120Z"
DESCRIPTION
"-v1.20
-Added additional AC power monitor items."
REVISION "201207090119Z"
DESCRIPTION
"-v1.19
-Removed wirelessBand object.
-Removed secSSH objects."
REVISION "201206120118Z"
DESCRIPTION
"-v1.18
-Removed user credentials objects.
-Added combined power distributor status objects."
REVISION "201204090117Z"
DESCRIPTION
"-v1.17
-Added eth2WanRoutingEnable object."
REVISION "201204050116Z"
DESCRIPTION
"-v1.16
-Added combined eventsensor status objects."
REVISION "201203060115Z"
DESCRIPTION
"-v1.15
-Added objects and trap definitions for fuel sensor and AC power monitor."
REVISION "201112050900Z"
DESCRIPTION
"-v1.14
-Added s571StockScriptTrap notification definition."
REVISION "201110240900Z"
DESCRIPTION
"-v1.13
-Added s571StockLoadSheddingTrap notification definition."
REVISION "201108080900Z"
DESCRIPTION
"-v1.12
-Added s571StockOutputTrap notification definition."
REVISION "201108010900Z"
DESCRIPTION
"-v1.11
-Added evMgmtReprocess object."
REVISION "201107200900Z"
DESCRIPTION
"-v1.10
-Added aisgStatus branch."
REVISION "201107080900Z"
DESCRIPTION
"-v1.09
-Added wirelessModemStatus branch."
REVISION "201101050900Z"
DESCRIPTION
"-v1.08
-Added espcCCNormalThreshold object."
REVISION "201012010900Z"
DESCRIPTION
"-v1.07
-Added support for PowerBoss external power distributors. This is in the
pdNextGen object branch which also supports the internal power distributor
of the SiteBoss 571. The old SNMP support for the internal power
distributor is kept in the older sub-branches of the powerDistributionStatus
branch (pdConfig, pdMain, pdOutput). The idea behind the pdNextGen object
branch is that there are 31 items for power monitoring and alarming, and
these items are organized in a double-indexed SNMP table object: the first
index is for the power distributor (and has the same numbering scheme as an
EventSensor -- like esIndexES, but is called pdnIndexPD), and the second
index is the power output to which the item applies (or just '1' if the item
is not specific to a particular power output). E.g., to read the main
current of the internal power distributor, you can use the old object
(pdMainCurrentValue.0) or you can use the new object
(pdnMainCurrentValue.200.1). To read the fuse event state of power output
number 8 on the power distributor (PowerBoss) at index 2, read
pdnOutputFuseInEventState.2.8."
REVISION "201011030900Z"
DESCRIPTION
"-v1.06
-Changed deadband, threshold, and current values for temperature
sensors from integer to floating-point type. This means the
SNMP object type for the temperature settings (deadbands and
thresholds) changed from Integer32 to DisplayString.
-Fixed bug where SNMP integer range defined in the MIB for
trapIncludedValue was 16-bit instead of 32-bit."
REVISION "201008240900Z"
DESCRIPTION
"-v1.05
-Fixed bug where some stock traps had too few varbinds declared.
-Removed useless trap definitions."
REVISION "201003170900Z"
DESCRIPTION
"-v1.04
-Removed useless object consoleInlineHsk.
-Added asset management object branch.
-Added altitude location object.
-Removed all obsolete switch references, made everything consistent
on outputs (relay outputs or power outputs).
-Added threshold objects for power distribution sensors.
-Added pdOutputCurrentValue object.
-Fixed description for pdOutputCurrentInEventState."
REVISION "201001190900Z"
DESCRIPTION
"-v1.03
-Increased range for esPointValueInt"
REVISION "200910080900Z"
DESCRIPTION
"-v1.02
-Incremental pre-release changes"
REVISION "200910050900Z"
DESCRIPTION
"-v1.01
-Incremental pre-release changes"
REVISION "200909170900Z"
DESCRIPTION
"-v1.00
-Initial version."
::= { asentria 14 }s571 MODULE-IDENTITY
LAST-UPDATED "201412300144Z"
ORGANIZATION "Asentria Corporation"
CONTACT-INFO
"Phone: 206-344-8800
Fax: 206-344-2116
Email: support@asentria.com"
DESCRIPTION
"MIB module for managing Asentria SiteBoss 571"
REVISION "201412300144Z"
DESCRIPTION
"-v1.44
-Removed wirelessPIN and scSecret objects (OMX-1064).
-Applicable since unit version 2.10.610."
REVISION "201412110143Z"
DESCRIPTION
"-v1.43
-Changed analog-input fuel sensor objects from Integer32 to DisplayString (OMX-1177).
-Added missing ipv6DefaultRouter object (OMX-1175).
-Applicable since unit version 2.10.580."
REVISION "201410160142Z"
DESCRIPTION
"-v1.42
-Added espcAIDisplayFormat object (OMX-1112).
-Removed espcAIPolarity, espcAIConvHighSign, espcAIConvLowSign objects (OMX-1113).
-Applicable since unit version 2.10.460."
REVISION "201410030141Z"
DESCRIPTION
"-v1.41
-Changed analog input objects from Integer32 to DisplayString.
-Applicable since unit version 2.10.460."
REVISION "201408140140Z"
DESCRIPTION
"-v1.40
-Fixed description for wirelessConnIP objects (OMX-1061).
-Applicable since unit version 2.10.390."
REVISION "201407030139Z"
DESCRIPTION
"-v1.39
-Fixed wirelessIdleTimeout (OMX-1037).
-Fixed CPE status objects (OMX-1036).
-Applicable since unit version 2.10.390."
REVISION "201406240138Z"
DESCRIPTION
"-v1.38
-Fixed CPE status objects.
-Applicable since unit version 2.10.340."
REVISION "201405290137Z"
DESCRIPTION
"-v1.37
-Added various missing objects (OMX-751).
-Added CPE objects (OMX-162).
-Applicable since unit version 2.10.320."
REVISION "201404110136Z"
DESCRIPTION
"-v1.36
-Clarified relay and power output function and documentation (OMX-926).
-Applicable since unit version 2.10.300."
REVISION "201401170135Z"
DESCRIPTION
"-v1.35
-Added IPv6 objects (OMX-705).
-Added power distribution objects (powerDistributionStatus branch) (OMX-708).
-Fixed ipRestrictionMask wrong type (OMX-743).
-Added ftpPushPermissions (OMX-737).
-Added snmpProxy objects (OMX-747).
-Applicable since unit version 2.10.150."
REVISION "201312040134Z"
DESCRIPTION
"-v1.34
-Added fsGenEnable (OMX-661).
-Applicable since unit version 2.10.110."
REVISION "201309040133Z"
DESCRIPTION
"-v1.33
-Added pdSystemCurrent and pdSystemPower objects (OMX-527).
-Added pdnDeviceCurrentValue and pdnDeviceCurrentValueStr objects (OMX-528).
-Applicable since unit version 2.09.626."
REVISION "201308010132Z"
DESCRIPTION
"-v1.32
-Added missing trapEventTypeNumber available values in description (OMX-437).
-Applicable since unit version 2.09.560."
REVISION "201307170131Z"
DESCRIPTION
"-v1.31
-Corrected snmpPBufferAllPeriod object.
-Applicable since unit version 2.09.560."
REVISION "201307020130Z"
DESCRIPTION
"-v1.30
-Added snmpPoll objects (OMX-394).
-Applicable since unit version 2.09.560."
REVISION "201306280129Z"
DESCRIPTION
"-v1.29
-Removed Ethernet Expansion card objects.
-Applicable since unit version 2.09.540."
REVISION "201306130128Z"
DESCRIPTION
"-v1.28
-Added sysFileTransfer and sysUpdate objects. (OMX-42)
-Applicable since unit version 2.09.520."
REVISION "201306120127Z"
DESCRIPTION
"-v1.27
-Renamed EX10 to Ethernet Expansion (OMX-364)
-Applicable since unit version 2.09.510."
REVISION "201305280126Z"
DESCRIPTION
"-v1.26
-Fixed incorrect SYNTAX for sysCharMask (OMX-328).
-Applicable since unit version 2.09.380."
REVISION "201305100125Z"
DESCRIPTION
"-v1.25
-Fixed incorrect SYNTAX statements for various objects (OMX-314).
-Applicable since unit version 2.09.380."
REVISION "201303150124Z"
DESCRIPTION
"-v1.24
-Renamed sysLocation branch to sysLoc (OMX-198).
-Applicable since unit version 2.09.240."
REVISION "201302060123Z"
DESCRIPTION
"-v1.23
-Added ex10 branch.
-Renamed telnet* objects.
-Applicable since unit version 2.09.240."
REVISION "201301140122Z"
DESCRIPTION
"-v1.22
-Added evReset branch and associated notification (OMX-83).
-Applicable since unit version 2.09.220."
REVISION "201211260121Z"
DESCRIPTION
"-v1.21
-Fixed backwards pppRoutingEnable/ethRoutingEnable comments. (BN 4620)"
REVISION "201208220120Z"
DESCRIPTION
"-v1.20
-Added additional AC power monitor items."
REVISION "201207090119Z"
DESCRIPTION
"-v1.19
-Removed wirelessBand object.
-Removed secSSH objects."
REVISION "201206120118Z"
DESCRIPTION
"-v1.18
-Removed user credentials objects.
-Added combined power distributor status objects."
REVISION "201204090117Z"
DESCRIPTION
"-v1.17
-Added eth2WanRoutingEnable object."
REVISION "201204050116Z"
DESCRIPTION
"-v1.16
-Added combined eventsensor status objects."
REVISION "201203060115Z"
DESCRIPTION
"-v1.15
-Added objects and trap definitions for fuel sensor and AC power monitor."
REVISION "201112050900Z"
DESCRIPTION
"-v1.14
-Added s571StockScriptTrap notification definition."
REVISION "201110240900Z"
DESCRIPTION
"-v1.13
-Added s571StockLoadSheddingTrap notification definition."
REVISION "201108080900Z"
DESCRIPTION
"-v1.12
-Added s571StockOutputTrap notification definition."
REVISION "201108010900Z"
DESCRIPTION
"-v1.11
-Added evMgmtReprocess object."
REVISION "201107200900Z"
DESCRIPTION
"-v1.10
-Added aisgStatus branch."
REVISION "201107080900Z"
DESCRIPTION
"-v1.09
-Added wirelessModemStatus branch."
REVISION "201101050900Z"
DESCRIPTION
"-v1.08
-Added espcCCNormalThreshold object."
REVISION "201012010900Z"
DESCRIPTION
"-v1.07
-Added support for PowerBoss external power distributors. This is in the
pdNextGen object branch which also supports the internal power distributor
of the SiteBoss 571. The old SNMP support for the internal power
distributor is kept in the older sub-branches of the powerDistributionStatus
branch (pdConfig, pdMain, pdOutput). The idea behind the pdNextGen object
branch is that there are 31 items for power monitoring and alarming, and
these items are organized in a double-indexed SNMP table object: the first
index is for the power distributor (and has the same numbering scheme as an
EventSensor -- like esIndexES, but is called pdnIndexPD), and the second
index is the power output to which the item applies (or just '1' if the item
is not specific to a particular power output). E.g., to read the main
current of the internal power distributor, you can use the old object
(pdMainCurrentValue.0) or you can use the new object
(pdnMainCurrentValue.200.1). To read the fuse event state of power output
number 8 on the power distributor (PowerBoss) at index 2, read
pdnOutputFuseInEventState.2.8."
REVISION "201011030900Z"
DESCRIPTION
"-v1.06
-Changed deadband, threshold, and current values for temperature
sensors from integer to floating-point type. This means the
SNMP object type for the temperature settings (deadbands and
thresholds) changed from Integer32 to DisplayString.
-Fixed bug where SNMP integer range defined in the MIB for
trapIncludedValue was 16-bit instead of 32-bit."
REVISION "201008240900Z"
DESCRIPTION
"-v1.05
-Fixed bug where some stock traps had too few varbinds declared.
-Removed useless trap definitions."
REVISION "201003170900Z"
DESCRIPTION
"-v1.04
-Removed useless object consoleInlineHsk.
-Added asset management object branch.
-Added altitude location object.
-Removed all obsolete switch references, made everything consistent
on outputs (relay outputs or power outputs).
-Added threshold objects for power distribution sensors.
-Added pdOutputCurrentValue object.
-Fixed description for pdOutputCurrentInEventState."
REVISION "201001190900Z"
DESCRIPTION
"-v1.03
-Increased range for esPointValueInt"
REVISION "200910080900Z"
DESCRIPTION
"-v1.02
-Incremental pre-release changes"
REVISION "200910050900Z"
DESCRIPTION
"-v1.01
-Incremental pre-release changes"
REVISION "200909170900Z"
DESCRIPTION
"-v1.00
-Initial version."
::= { asentria 14 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
MIB module for managing Asentria SiteBoss 571
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: unspecified.
Names: s571
{
"smi_kind": "MODULE-IDENTITY",
"definition": [
"s571",
"MODULE-IDENTITY",
"LAST-UPDATED",
[
"literal",
"223230313431323131303134335a22"
],
"ORGANIZATION",
"\"Asentria Corporation\"",
"CONTACT-INFO",
"\"Phone: 206-344-8800 Fax: 206-344-2116 Email: support@asentria.com\"",
"DESCRIPTION",
"\"MIB module for managing Asentria SiteBoss 571\"",
"REVISION",
[
"literal",
"223230313431323131303134335a22"
],
"DESCRIPTION",
"\"-v1.43 -Changed analog-input fuel sensor objects from Integer32 to DisplayString (OMX-1177). -Added missing ipv6DefaultRouter object (OMX-1175). -Applicable since unit version 2.10.580.\"",
"REVISION",
[
"literal",
"223230313431303136303134325a22"
],
"DESCRIPTION",
"\"-v1.42 -Added espcAIDisplayFormat object (OMX-1112). -Removed espcAIPolarity, espcAIConvHighSign, espcAIConvLowSign objects (OMX-1113). -Applicable since unit version 2.10.460.\"",
"REVISION",
[
"literal",
"223230313431303033303134315a22"
],
"DESCRIPTION",
"\"-v1.41 -Changed analog input objects from Integer32 to DisplayString. -Applicable since unit version 2.10.460.\"",
"REVISION",
[
"literal",
"223230313430383134303134305a22"
],
"DESCRIPTION",
"\"-v1.40 -Fixed description for wirelessConnIP objects (OMX-1061). -Applicable since unit version 2.10.390.\"",
"REVISION",
[
"literal",
"223230313430373033303133395a22"
],
"DESCRIPTION",
"\"-v1.39 -Fixed wirelessIdleTimeout (OMX-1037). -Fixed CPE status objects (OMX-1036). -Applicable since unit version 2.10.390.\"",
"REVISION",
[
"literal",
"223230313430363234303133385a22"
],
"DESCRIPTION",
"\"-v1.38 -Fixed CPE status objects. -Applicable since unit version 2.10.340.\"",
"REVISION",
[
"literal",
"223230313430353239303133375a22"
],
"DESCRIPTION",
"\"-v1.37 -Added various missing objects (OMX-751). -Added CPE objects (OMX-162). -Applicable since unit version 2.10.320.\"",
"REVISION",
[
"literal",
"223230313430343131303133365a22"
],
"DESCRIPTION",
"\"-v1.36 -Clarified relay and power output function and documentation (OMX-926). -Applicable since unit version 2.10.300.\"",
"REVISION",
[
"literal",
"223230313430313137303133355a22"
],
"DESCRIPTION",
"\"-v1.35 -Added IPv6 objects (OMX-705). -Added power distribution objects (powerDistributionStatus branch) (OMX-708). -Fixed ipRestrictionMask wrong type (OMX-743). -Added ftpPushPermissions (OMX-737). -Added snmpProxy objects (OMX-747). -Applicable since unit version 2.10.150.\"",
"REVISION",
[
"literal",
"223230313331323034303133345a22"
],
"DESCRIPTION",
"\"-v1.34 -Added fsGenEnable (OMX-661). -Applicable since unit version 2.10.110.\"",
"REVISION",
[
"literal",
"223230313330393034303133335a22"
],
"DESCRIPTION",
"\"-v1.33 -Added pdSystemCurrent and pdSystemPower objects (OMX-527). -Added pdnDeviceCurrentValue and pdnDeviceCurrentValueStr objects (OMX-528). -Applicable since unit version 2.09.626.\"",
"REVISION",
[
"literal",
"223230313330383031303133325a22"
],
"DESCRIPTION",
"\"-v1.32 -Added missing trapEventTypeNumber available values in description (OMX-437). -Applicable since unit version 2.09.560.\"",
"REVISION",
[
"literal",
"223230313330373137303133315a22"
],
"DESCRIPTION",
"\"-v1.31 -Corrected snmpPBufferAllPeriod object. -Applicable since unit version 2.09.560.\"",
"REVISION",
[
"literal",
"223230313330373032303133305a22"
],
"DESCRIPTION",
"\"-v1.30 -Added snmpPoll objects (OMX-394). -Applicable since unit version 2.09.560.\"",
"REVISION",
[
"literal",
"223230313330363238303132395a22"
],
"DESCRIPTION",
"\"-v1.29 -Removed Ethernet Expansion card objects. -Applicable since unit version 2.09.540.\"",
"REVISION",
[
"literal",
"223230313330363133303132385a22"
],
"DESCRIPTION",
"\"-v1.28 -Added sysFileTransfer and sysUpdate objects. (OMX-42) -Applicable since unit version 2.09.520.\"",
"REVISION",
[
"literal",
"223230313330363132303132375a22"
],
"DESCRIPTION",
"\"-v1.27 -Renamed EX10 to Ethernet Expansion (OMX-364) -Applicable since unit version 2.09.510.\"",
"REVISION",
[
"literal",
"223230313330353238303132365a22"
],
"DESCRIPTION",
"\"-v1.26 -Fixed incorrect SYNTAX for sysCharMask (OMX-328). -Applicable since unit version 2.09.380.\"",
"REVISION",
[
"literal",
"223230313330353130303132355a22"
],
"DESCRIPTION",
"\"-v1.25 -Fixed incorrect SYNTAX statements for various objects (OMX-314). -Applicable since unit version 2.09.380.\"",
"REVISION",
[
"literal",
"223230313330333135303132345a22"
],
"DESCRIPTION",
"\"-v1.24 -Renamed sysLocation branch to sysLoc (OMX-198). -Applicable since unit version 2.09.240.\"",
"REVISION",
[
"literal",
"223230313330323036303132335a22"
],
"DESCRIPTION",
"\"-v1.23 -Added ex10 branch. -Renamed telnet* objects. -Applicable since unit version 2.09.240.\"",
"REVISION",
[
"literal",
"223230313330313134303132325a22"
],
"DESCRIPTION",
"\"-v1.22 -Added evReset branch and associated notification (OMX-83). -Applicable since unit version 2.09.220.\"",
"REVISION",
[
"literal",
"223230313231313236303132315a22"
],
"DESCRIPTION",
"\"-v1.21 -Fixed backwards pppRoutingEnable/ethRoutingEnable comments. (BN 4620)\"",
"REVISION",
[
"literal",
"223230313230383232303132305a22"
],
"DESCRIPTION",
"\"-v1.20 -Added additional AC power monitor items.\"",
"REVISION",
[
"literal",
"223230313230373039303131395a22"
],
"DESCRIPTION",
"\"-v1.19 -Removed wirelessBand object. -Removed secSSH objects.\"",
"REVISION",
[
"literal",
"223230313230363132303131385a22"
],
"DESCRIPTION",
"\"-v1.18 -Removed user credentials objects. -Added combined power distributor status objects.\"",
"REVISION",
[
"literal",
"223230313230343039303131375a22"
],
"DESCRIPTION",
"\"-v1.17 -Added eth2WanRoutingEnable object.\"",
"REVISION",
[
"literal",
"223230313230343035303131365a22"
],
"DESCRIPTION",
"\"-v1.16 -Added combined eventsensor status objects.\"",
"REVISION",
[
"literal",
"223230313230333036303131355a22"
],
"DESCRIPTION",
"\"-v1.15 -Added objects and trap definitions for fuel sensor and AC power monitor.\"",
"REVISION",
[
"literal",
"223230313131323035303930305a22"
],
"DESCRIPTION",
"\"-v1.14 -Added s571StockScriptTrap notification definition.\"",
"REVISION",
[
"literal",
"223230313131303234303930305a22"
],
"DESCRIPTION",
"\"-v1.13 -Added s571StockLoadSheddingTrap notification definition.\"",
"REVISION",
[
"literal",
"223230313130383038303930305a22"
],
"DESCRIPTION",
"\"-v1.12 -Added s571StockOutputTrap notification definition.\"",
"REVISION",
[
"literal",
"223230313130383031303930305a22"
],
"DESCRIPTION",
"\"-v1.11 -Added evMgmtReprocess object.\"",
"REVISION",
[
"literal",
"223230313130373230303930305a22"
],
"DESCRIPTION",
"\"-v1.10 -Added aisgStatus branch.\"",
"REVISION",
[
"literal",
"223230313130373038303930305a22"
],
"DESCRIPTION",
"\"-v1.09 -Added wirelessModemStatus branch.\"",
"REVISION",
[
"literal",
"223230313130313035303930305a22"
],
"DESCRIPTION",
"\"-v1.08 -Added espcCCNormalThreshold object.\"",
"REVISION",
[
"literal",
"223230313031323031303930305a22"
],
"DESCRIPTION",
"\"-v1.07 -Added support for PowerBoss external power distributors. This is in the pdNextGen object branch which also supports the internal power distributor of the SiteBoss 571. The old SNMP support for the internal power distributor is kept in the older sub-branches of the powerDistributionStatus branch (pdConfig, pdMain, pdOutput). The idea behind the pdNextGen object branch is that there are 31 items for power monitoring and alarming, and these items are organized in a double-indexed SNMP table object: the first index is for the power distributor (and has the same numbering scheme as an EventSensor -- like esIndexES, but is called pdnIndexPD), and the second index is the power output to which the item applies (or just '1' if the item is not specific to a particular power output). E.g., to read the main current of the internal power distributor, you can use the old object (pdMainCurrentValue.0) or you can use the new object (pdnMainCurrentValue.200.1). To read the fuse event state of power output number 8 on the power distributor (PowerBoss) at index 2, read pdnOutputFuseInEventState.2.8.\"",
"REVISION",
[
"literal",
"223230313031313033303930305a22"
],
"DESCRIPTION",
"\"-v1.06 -Changed deadband, threshold, and current values for temperature sensors from integer to floating-point type. This means the SNMP object type for the temperature settings (deadbands and thresholds) changed from Integer32 to DisplayString. -Fixed bug where SNMP integer range defined in the MIB for trapIncludedValue was 16-bit instead of 32-bit.\"",
"REVISION",
[
"literal",
"223230313030383234303930305a22"
],
"DESCRIPTION",
"\"-v1.05 -Fixed bug where some stock traps had too few varbinds declared. -Removed useless trap definitions.\"",
"REVISION",
[
"literal",
"223230313030333137303930305a22"
],
"DESCRIPTION",
"\"-v1.04 -Removed useless object consoleInlineHsk. -Added asset management object branch. -Added altitude location object. -Removed all obsolete switch references, made everything consistent on outputs (relay outputs or power outputs). -Added threshold objects for power distribution sensors. -Added pdOutputCurrentValue object. -Fixed description for pdOutputCurrentInEventState.\"",
"REVISION",
[
"literal",
"223230313030313139303930305a22"
],
"DESCRIPTION",
"\"-v1.03 -Increased range for esPointValueInt\"",
"REVISION",
[
"literal",
"223230303931303038303930305a22"
],
"DESCRIPTION",
"\"-v1.02 -Incremental pre-release changes\"",
"REVISION",
[
"literal",
"223230303931303035303930305a22"
],
"DESCRIPTION",
"\"-v1.01 -Incremental pre-release changes\"",
"REVISION",
[
"literal",
"223230303930393137303930305a22"
],
"DESCRIPTION",
"\"-v1.00 -Initial version.\"",
"::=",
"{",
"asentria",
"14",
"}"
],
"syntax_tree": [
[
"LAST-UPDATED",
"201412110143Z"
],
[
"ORGANIZATION",
"Asentria Corporation"
],
[
"CONTACT-INFO",
"Phone: 206-344-8800 Fax: 206-344-2116 Email: support@asentria.com"
],
[
"DESCRIPTION",
"MIB module for managing Asentria SiteBoss 571"
],
[
"Revisions",
[
[
"201412110143Z",
[
"DESCRIPTION",
"-v1.43 -Changed analog-input fuel sensor objects from Integer32 to DisplayString (OMX-1177). -Added missing ipv6DefaultRouter object (OMX-1175). -Applicable since unit version 2.10.580."
]
],
[
"201410160142Z",
[
"DESCRIPTION",
"-v1.42 -Added espcAIDisplayFormat object (OMX-1112). -Removed espcAIPolarity, espcAIConvHighSign, espcAIConvLowSign objects (OMX-1113). -Applicable since unit version 2.10.460."
]
],
[
"201410030141Z",
[
"DESCRIPTION",
"-v1.41 -Changed analog input objects from Integer32 to DisplayString. -Applicable since unit version 2.10.460."
]
],
[
"201408140140Z",
[
"DESCRIPTION",
"-v1.40 -Fixed description for wirelessConnIP objects (OMX-1061). -Applicable since unit version 2.10.390."
]
],
[
"201407030139Z",
[
"DESCRIPTION",
"-v1.39 -Fixed wirelessIdleTimeout (OMX-1037). -Fixed CPE status objects (OMX-1036). -Applicable since unit version 2.10.390."
]
],
[
"201406240138Z",
[
"DESCRIPTION",
"-v1.38 -Fixed CPE status objects. -Applicable since unit version 2.10.340."
]
],
[
"201405290137Z",
[
"DESCRIPTION",
"-v1.37 -Added various missing objects (OMX-751). -Added CPE objects (OMX-162). -Applicable since unit version 2.10.320."
]
],
[
"201404110136Z",
[
"DESCRIPTION",
"-v1.36 -Clarified relay and power output function and documentation (OMX-926). -Applicable since unit version 2.10.300."
]
],
[
"201401170135Z",
[
"DESCRIPTION",
"-v1.35 -Added IPv6 objects (OMX-705). -Added power distribution objects (powerDistributionStatus branch) (OMX-708). -Fixed ipRestrictionMask wrong type (OMX-743). -Added ftpPushPermissions (OMX-737). -Added snmpProxy objects (OMX-747). -Applicable since unit version 2.10.150."
]
],
[
"201312040134Z",
[
"DESCRIPTION",
"-v1.34 -Added fsGenEnable (OMX-661). -Applicable since unit version 2.10.110."
]
],
[
"201309040133Z",
[
"DESCRIPTION",
"-v1.33 -Added pdSystemCurrent and pdSystemPower objects (OMX-527). -Added pdnDeviceCurrentValue and pdnDeviceCurrentValueStr objects (OMX-528). -Applicable since unit version 2.09.626."
]
],
[
"201308010132Z",
[
"DESCRIPTION",
"-v1.32 -Added missing trapEventTypeNumber available values in description (OMX-437). -Applicable since unit version 2.09.560."
]
],
[
"201307170131Z",
[
"DESCRIPTION",
"-v1.31 -Corrected snmpPBufferAllPeriod object. -Applicable since unit version 2.09.560."
]
],
[
"201307020130Z",
[
"DESCRIPTION",
"-v1.30 -Added snmpPoll objects (OMX-394). -Applicable since unit version 2.09.560."
]
],
[
"201306280129Z",
[
"DESCRIPTION",
"-v1.29 -Removed Ethernet Expansion card objects. -Applicable since unit version 2.09.540."
]
],
[
"201306130128Z",
[
"DESCRIPTION",
"-v1.28 -Added sysFileTransfer and sysUpdate objects. (OMX-42) -Applicable since unit version 2.09.520."
]
],
[
"201306120127Z",
[
"DESCRIPTION",
"-v1.27 -Renamed EX10 to Ethernet Expansion (OMX-364) -Applicable since unit version 2.09.510."
]
],
[
"201305280126Z",
[
"DESCRIPTION",
"-v1.26 -Fixed incorrect SYNTAX for sysCharMask (OMX-328). -Applicable since unit version 2.09.380."
]
],
[
"201305100125Z",
[
"DESCRIPTION",
"-v1.25 -Fixed incorrect SYNTAX statements for various objects (OMX-314). -Applicable since unit version 2.09.380."
]
],
[
"201303150124Z",
[
"DESCRIPTION",
"-v1.24 -Renamed sysLocation branch to sysLoc (OMX-198). -Applicable since unit version 2.09.240."
]
],
[
"201302060123Z",
[
"DESCRIPTION",
"-v1.23 -Added ex10 branch. -Renamed telnet* objects. -Applicable since unit version 2.09.240."
]
],
[
"201301140122Z",
[
"DESCRIPTION",
"-v1.22 -Added evReset branch and associated notification (OMX-83). -Applicable since unit version 2.09.220."
]
],
[
"201211260121Z",
[
"DESCRIPTION",
"-v1.21 -Fixed backwards pppRoutingEnable/ethRoutingEnable comments. (BN 4620)"
]
],
[
"201208220120Z",
[
"DESCRIPTION",
"-v1.20 -Added additional AC power monitor items."
]
],
[
"201207090119Z",
[
"DESCRIPTION",
"-v1.19 -Removed wirelessBand object. -Removed secSSH objects."
]
],
[
"201206120118Z",
[
"DESCRIPTION",
"-v1.18 -Removed user credentials objects. -Added combined power distributor status objects."
]
],
[
"201204090117Z",
[
"DESCRIPTION",
"-v1.17 -Added eth2WanRoutingEnable object."
]
],
[
"201204050116Z",
[
"DESCRIPTION",
"-v1.16 -Added combined eventsensor status objects."
]
],
[
"201203060115Z",
[
"DESCRIPTION",
"-v1.15 -Added objects and trap definitions for fuel sensor and AC power monitor."
]
],
[
"201112050900Z",
[
"DESCRIPTION",
"-v1.14 -Added s571StockScriptTrap notification definition."
]
],
[
"201110240900Z",
[
"DESCRIPTION",
"-v1.13 -Added s571StockLoadSheddingTrap notification definition."
]
],
[
"201108080900Z",
[
"DESCRIPTION",
"-v1.12 -Added s571StockOutputTrap notification definition."
]
],
[
"201108010900Z",
[
"DESCRIPTION",
"-v1.11 -Added evMgmtReprocess object."
]
],
[
"201107200900Z",
[
"DESCRIPTION",
"-v1.10 -Added aisgStatus branch."
]
],
[
"201107080900Z",
[
"DESCRIPTION",
"-v1.09 -Added wirelessModemStatus branch."
]
],
[
"201101050900Z",
[
"DESCRIPTION",
"-v1.08 -Added espcCCNormalThreshold object."
]
],
[
"201012010900Z",
[
"DESCRIPTION",
"-v1.07 -Added support for PowerBoss external power distributors. This is in the pdNextGen object branch which also supports the internal power distributor of the SiteBoss 571. The old SNMP support for the internal power distributor is kept in the older sub-branches of the powerDistributionStatus branch (pdConfig, pdMain, pdOutput). The idea behind the pdNextGen object branch is that there are 31 items for power monitoring and alarming, and these items are organized in a double-indexed SNMP table object: the first index is for the power distributor (and has the same numbering scheme as an EventSensor -- like esIndexES, but is called pdnIndexPD), and the second index is the power output to which the item applies (or just '1' if the item is not specific to a particular power output). E.g., to read the main current of the internal power distributor, you can use the old object (pdMainCurrentValue.0) or you can use the new object (pdnMainCurrentValue.200.1). To read the fuse event state of power output number 8 on the power distributor (PowerBoss) at index 2, read pdnOutputFuseInEventState.2.8."
]
],
[
"201011030900Z",
[
"DESCRIPTION",
"-v1.06 -Changed deadband, threshold, and current values for temperature sensors from integer to floating-point type. This means the SNMP object type for the temperature settings (deadbands and thresholds) changed from Integer32 to DisplayString. -Fixed bug where SNMP integer range defined in the MIB for trapIncludedValue was 16-bit instead of 32-bit."
]
],
[
"201008240900Z",
[
"DESCRIPTION",
"-v1.05 -Fixed bug where some stock traps had too few varbinds declared. -Removed useless trap definitions."
]
],
[
"201003170900Z",
[
"DESCRIPTION",
"-v1.04 -Removed useless object consoleInlineHsk. -Added asset management object branch. -Added altitude location object. -Removed all obsolete switch references, made everything consistent on outputs (relay outputs or power outputs). -Added threshold objects for power distribution sensors. -Added pdOutputCurrentValue object. -Fixed description for pdOutputCurrentInEventState."
]
],
[
"201001190900Z",
[
"DESCRIPTION",
"-v1.03 -Increased range for esPointValueInt"
]
],
[
"200910080900Z",
[
"DESCRIPTION",
"-v1.02 -Incremental pre-release changes"
]
],
[
"200910050900Z",
[
"DESCRIPTION",
"-v1.01 -Incremental pre-release changes"
]
],
[
"200909170900Z",
[
"DESCRIPTION",
"-v1.00 -Initial version."
]
]
]
]
]
}Vendor MIB copy from the Observium Community archive.
Module: SITEBOSS-571-STD-MIB
See published definition above
{'SNMPv2-TC': ['DisplayString'], 'SNMPv2-SMI': ['IpAddress', 'TimeTicks', 'Integer32', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE', 'OBJECT-TYPE'], 'ASENTRIA-ROOT-MIB': ['asentria']}Related source files and packages:
Status in source: unspecified.
Names: s571
{
"smi_kind": "MODULE-IDENTITY",
"definition": [
"s571",
"MODULE-IDENTITY",
"LAST-UPDATED",
[
"literal",
"223230313431323330303134345a22"
],
"ORGANIZATION",
"\"Asentria Corporation\"",
"CONTACT-INFO",
"\"Phone: 206-344-8800 Fax: 206-344-2116 Email: support@asentria.com\"",
"DESCRIPTION",
"\"MIB module for managing Asentria SiteBoss 571\"",
"REVISION",
[
"literal",
"223230313431323330303134345a22"
],
"DESCRIPTION",
"\"-v1.44 -Removed wirelessPIN and scSecret objects (OMX-1064). -Applicable since unit version 2.10.610.\"",
"REVISION",
[
"literal",
"223230313431323131303134335a22"
],
"DESCRIPTION",
"\"-v1.43 -Changed analog-input fuel sensor objects from Integer32 to DisplayString (OMX-1177). -Added missing ipv6DefaultRouter object (OMX-1175). -Applicable since unit version 2.10.580.\"",
"REVISION",
[
"literal",
"223230313431303136303134325a22"
],
"DESCRIPTION",
"\"-v1.42 -Added espcAIDisplayFormat object (OMX-1112). -Removed espcAIPolarity, espcAIConvHighSign, espcAIConvLowSign objects (OMX-1113). -Applicable since unit version 2.10.460.\"",
"REVISION",
[
"literal",
"223230313431303033303134315a22"
],
"DESCRIPTION",
"\"-v1.41 -Changed analog input objects from Integer32 to DisplayString. -Applicable since unit version 2.10.460.\"",
"REVISION",
[
"literal",
"223230313430383134303134305a22"
],
"DESCRIPTION",
"\"-v1.40 -Fixed description for wirelessConnIP objects (OMX-1061). -Applicable since unit version 2.10.390.\"",
"REVISION",
[
"literal",
"223230313430373033303133395a22"
],
"DESCRIPTION",
"\"-v1.39 -Fixed wirelessIdleTimeout (OMX-1037). -Fixed CPE status objects (OMX-1036). -Applicable since unit version 2.10.390.\"",
"REVISION",
[
"literal",
"223230313430363234303133385a22"
],
"DESCRIPTION",
"\"-v1.38 -Fixed CPE status objects. -Applicable since unit version 2.10.340.\"",
"REVISION",
[
"literal",
"223230313430353239303133375a22"
],
"DESCRIPTION",
"\"-v1.37 -Added various missing objects (OMX-751). -Added CPE objects (OMX-162). -Applicable since unit version 2.10.320.\"",
"REVISION",
[
"literal",
"223230313430343131303133365a22"
],
"DESCRIPTION",
"\"-v1.36 -Clarified relay and power output function and documentation (OMX-926). -Applicable since unit version 2.10.300.\"",
"REVISION",
[
"literal",
"223230313430313137303133355a22"
],
"DESCRIPTION",
"\"-v1.35 -Added IPv6 objects (OMX-705). -Added power distribution objects (powerDistributionStatus branch) (OMX-708). -Fixed ipRestrictionMask wrong type (OMX-743). -Added ftpPushPermissions (OMX-737). -Added snmpProxy objects (OMX-747). -Applicable since unit version 2.10.150.\"",
"REVISION",
[
"literal",
"223230313331323034303133345a22"
],
"DESCRIPTION",
"\"-v1.34 -Added fsGenEnable (OMX-661). -Applicable since unit version 2.10.110.\"",
"REVISION",
[
"literal",
"223230313330393034303133335a22"
],
"DESCRIPTION",
"\"-v1.33 -Added pdSystemCurrent and pdSystemPower objects (OMX-527). -Added pdnDeviceCurrentValue and pdnDeviceCurrentValueStr objects (OMX-528). -Applicable since unit version 2.09.626.\"",
"REVISION",
[
"literal",
"223230313330383031303133325a22"
],
"DESCRIPTION",
"\"-v1.32 -Added missing trapEventTypeNumber available values in description (OMX-437). -Applicable since unit version 2.09.560.\"",
"REVISION",
[
"literal",
"223230313330373137303133315a22"
],
"DESCRIPTION",
"\"-v1.31 -Corrected snmpPBufferAllPeriod object. -Applicable since unit version 2.09.560.\"",
"REVISION",
[
"literal",
"223230313330373032303133305a22"
],
"DESCRIPTION",
"\"-v1.30 -Added snmpPoll objects (OMX-394). -Applicable since unit version 2.09.560.\"",
"REVISION",
[
"literal",
"223230313330363238303132395a22"
],
"DESCRIPTION",
"\"-v1.29 -Removed Ethernet Expansion card objects. -Applicable since unit version 2.09.540.\"",
"REVISION",
[
"literal",
"223230313330363133303132385a22"
],
"DESCRIPTION",
"\"-v1.28 -Added sysFileTransfer and sysUpdate objects. (OMX-42) -Applicable since unit version 2.09.520.\"",
"REVISION",
[
"literal",
"223230313330363132303132375a22"
],
"DESCRIPTION",
"\"-v1.27 -Renamed EX10 to Ethernet Expansion (OMX-364) -Applicable since unit version 2.09.510.\"",
"REVISION",
[
"literal",
"223230313330353238303132365a22"
],
"DESCRIPTION",
"\"-v1.26 -Fixed incorrect SYNTAX for sysCharMask (OMX-328). -Applicable since unit version 2.09.380.\"",
"REVISION",
[
"literal",
"223230313330353130303132355a22"
],
"DESCRIPTION",
"\"-v1.25 -Fixed incorrect SYNTAX statements for various objects (OMX-314). -Applicable since unit version 2.09.380.\"",
"REVISION",
[
"literal",
"223230313330333135303132345a22"
],
"DESCRIPTION",
"\"-v1.24 -Renamed sysLocation branch to sysLoc (OMX-198). -Applicable since unit version 2.09.240.\"",
"REVISION",
[
"literal",
"223230313330323036303132335a22"
],
"DESCRIPTION",
"\"-v1.23 -Added ex10 branch. -Renamed telnet* objects. -Applicable since unit version 2.09.240.\"",
"REVISION",
[
"literal",
"223230313330313134303132325a22"
],
"DESCRIPTION",
"\"-v1.22 -Added evReset branch and associated notification (OMX-83). -Applicable since unit version 2.09.220.\"",
"REVISION",
[
"literal",
"223230313231313236303132315a22"
],
"DESCRIPTION",
"\"-v1.21 -Fixed backwards pppRoutingEnable/ethRoutingEnable comments. (BN 4620)\"",
"REVISION",
[
"literal",
"223230313230383232303132305a22"
],
"DESCRIPTION",
"\"-v1.20 -Added additional AC power monitor items.\"",
"REVISION",
[
"literal",
"223230313230373039303131395a22"
],
"DESCRIPTION",
"\"-v1.19 -Removed wirelessBand object. -Removed secSSH objects.\"",
"REVISION",
[
"literal",
"223230313230363132303131385a22"
],
"DESCRIPTION",
"\"-v1.18 -Removed user credentials objects. -Added combined power distributor status objects.\"",
"REVISION",
[
"literal",
"223230313230343039303131375a22"
],
"DESCRIPTION",
"\"-v1.17 -Added eth2WanRoutingEnable object.\"",
"REVISION",
[
"literal",
"223230313230343035303131365a22"
],
"DESCRIPTION",
"\"-v1.16 -Added combined eventsensor status objects.\"",
"REVISION",
[
"literal",
"223230313230333036303131355a22"
],
"DESCRIPTION",
"\"-v1.15 -Added objects and trap definitions for fuel sensor and AC power monitor.\"",
"REVISION",
[
"literal",
"223230313131323035303930305a22"
],
"DESCRIPTION",
"\"-v1.14 -Added s571StockScriptTrap notification definition.\"",
"REVISION",
[
"literal",
"223230313131303234303930305a22"
],
"DESCRIPTION",
"\"-v1.13 -Added s571StockLoadSheddingTrap notification definition.\"",
"REVISION",
[
"literal",
"223230313130383038303930305a22"
],
"DESCRIPTION",
"\"-v1.12 -Added s571StockOutputTrap notification definition.\"",
"REVISION",
[
"literal",
"223230313130383031303930305a22"
],
"DESCRIPTION",
"\"-v1.11 -Added evMgmtReprocess object.\"",
"REVISION",
[
"literal",
"223230313130373230303930305a22"
],
"DESCRIPTION",
"\"-v1.10 -Added aisgStatus branch.\"",
"REVISION",
[
"literal",
"223230313130373038303930305a22"
],
"DESCRIPTION",
"\"-v1.09 -Added wirelessModemStatus branch.\"",
"REVISION",
[
"literal",
"223230313130313035303930305a22"
],
"DESCRIPTION",
"\"-v1.08 -Added espcCCNormalThreshold object.\"",
"REVISION",
[
"literal",
"223230313031323031303930305a22"
],
"DESCRIPTION",
"\"-v1.07 -Added support for PowerBoss external power distributors. This is in the pdNextGen object branch which also supports the internal power distributor of the SiteBoss 571. The old SNMP support for the internal power distributor is kept in the older sub-branches of the powerDistributionStatus branch (pdConfig, pdMain, pdOutput). The idea behind the pdNextGen object branch is that there are 31 items for power monitoring and alarming, and these items are organized in a double-indexed SNMP table object: the first index is for the power distributor (and has the same numbering scheme as an EventSensor -- like esIndexES, but is called pdnIndexPD), and the second index is the power output to which the item applies (or just '1' if the item is not specific to a particular power output). E.g., to read the main current of the internal power distributor, you can use the old object (pdMainCurrentValue.0) or you can use the new object (pdnMainCurrentValue.200.1). To read the fuse event state of power output number 8 on the power distributor (PowerBoss) at index 2, read pdnOutputFuseInEventState.2.8.\"",
"REVISION",
[
"literal",
"223230313031313033303930305a22"
],
"DESCRIPTION",
"\"-v1.06 -Changed deadband, threshold, and current values for temperature sensors from integer to floating-point type. This means the SNMP object type for the temperature settings (deadbands and thresholds) changed from Integer32 to DisplayString. -Fixed bug where SNMP integer range defined in the MIB for trapIncludedValue was 16-bit instead of 32-bit.\"",
"REVISION",
[
"literal",
"223230313030383234303930305a22"
],
"DESCRIPTION",
"\"-v1.05 -Fixed bug where some stock traps had too few varbinds declared. -Removed useless trap definitions.\"",
"REVISION",
[
"literal",
"223230313030333137303930305a22"
],
"DESCRIPTION",
"\"-v1.04 -Removed useless object consoleInlineHsk. -Added asset management object branch. -Added altitude location object. -Removed all obsolete switch references, made everything consistent on outputs (relay outputs or power outputs). -Added threshold objects for power distribution sensors. -Added pdOutputCurrentValue object. -Fixed description for pdOutputCurrentInEventState.\"",
"REVISION",
[
"literal",
"223230313030313139303930305a22"
],
"DESCRIPTION",
"\"-v1.03 -Increased range for esPointValueInt\"",
"REVISION",
[
"literal",
"223230303931303038303930305a22"
],
"DESCRIPTION",
"\"-v1.02 -Incremental pre-release changes\"",
"REVISION",
[
"literal",
"223230303931303035303930305a22"
],
"DESCRIPTION",
"\"-v1.01 -Incremental pre-release changes\"",
"REVISION",
[
"literal",
"223230303930393137303930305a22"
],
"DESCRIPTION",
"\"-v1.00 -Initial version.\"",
"::=",
"{",
"asentria",
"14",
"}"
],
"syntax_tree": [
[
"LAST-UPDATED",
"201412300144Z"
],
[
"ORGANIZATION",
"Asentria Corporation"
],
[
"CONTACT-INFO",
"Phone: 206-344-8800 Fax: 206-344-2116 Email: support@asentria.com"
],
[
"DESCRIPTION",
"MIB module for managing Asentria SiteBoss 571"
],
[
"Revisions",
[
[
"201412300144Z",
[
"DESCRIPTION",
"-v1.44 -Removed wirelessPIN and scSecret objects (OMX-1064). -Applicable since unit version 2.10.610."
]
],
[
"201412110143Z",
[
"DESCRIPTION",
"-v1.43 -Changed analog-input fuel sensor objects from Integer32 to DisplayString (OMX-1177). -Added missing ipv6DefaultRouter object (OMX-1175). -Applicable since unit version 2.10.580."
]
],
[
"201410160142Z",
[
"DESCRIPTION",
"-v1.42 -Added espcAIDisplayFormat object (OMX-1112). -Removed espcAIPolarity, espcAIConvHighSign, espcAIConvLowSign objects (OMX-1113). -Applicable since unit version 2.10.460."
]
],
[
"201410030141Z",
[
"DESCRIPTION",
"-v1.41 -Changed analog input objects from Integer32 to DisplayString. -Applicable since unit version 2.10.460."
]
],
[
"201408140140Z",
[
"DESCRIPTION",
"-v1.40 -Fixed description for wirelessConnIP objects (OMX-1061). -Applicable since unit version 2.10.390."
]
],
[
"201407030139Z",
[
"DESCRIPTION",
"-v1.39 -Fixed wirelessIdleTimeout (OMX-1037). -Fixed CPE status objects (OMX-1036). -Applicable since unit version 2.10.390."
]
],
[
"201406240138Z",
[
"DESCRIPTION",
"-v1.38 -Fixed CPE status objects. -Applicable since unit version 2.10.340."
]
],
[
"201405290137Z",
[
"DESCRIPTION",
"-v1.37 -Added various missing objects (OMX-751). -Added CPE objects (OMX-162). -Applicable since unit version 2.10.320."
]
],
[
"201404110136Z",
[
"DESCRIPTION",
"-v1.36 -Clarified relay and power output function and documentation (OMX-926). -Applicable since unit version 2.10.300."
]
],
[
"201401170135Z",
[
"DESCRIPTION",
"-v1.35 -Added IPv6 objects (OMX-705). -Added power distribution objects (powerDistributionStatus branch) (OMX-708). -Fixed ipRestrictionMask wrong type (OMX-743). -Added ftpPushPermissions (OMX-737). -Added snmpProxy objects (OMX-747). -Applicable since unit version 2.10.150."
]
],
[
"201312040134Z",
[
"DESCRIPTION",
"-v1.34 -Added fsGenEnable (OMX-661). -Applicable since unit version 2.10.110."
]
],
[
"201309040133Z",
[
"DESCRIPTION",
"-v1.33 -Added pdSystemCurrent and pdSystemPower objects (OMX-527). -Added pdnDeviceCurrentValue and pdnDeviceCurrentValueStr objects (OMX-528). -Applicable since unit version 2.09.626."
]
],
[
"201308010132Z",
[
"DESCRIPTION",
"-v1.32 -Added missing trapEventTypeNumber available values in description (OMX-437). -Applicable since unit version 2.09.560."
]
],
[
"201307170131Z",
[
"DESCRIPTION",
"-v1.31 -Corrected snmpPBufferAllPeriod object. -Applicable since unit version 2.09.560."
]
],
[
"201307020130Z",
[
"DESCRIPTION",
"-v1.30 -Added snmpPoll objects (OMX-394). -Applicable since unit version 2.09.560."
]
],
[
"201306280129Z",
[
"DESCRIPTION",
"-v1.29 -Removed Ethernet Expansion card objects. -Applicable since unit version 2.09.540."
]
],
[
"201306130128Z",
[
"DESCRIPTION",
"-v1.28 -Added sysFileTransfer and sysUpdate objects. (OMX-42) -Applicable since unit version 2.09.520."
]
],
[
"201306120127Z",
[
"DESCRIPTION",
"-v1.27 -Renamed EX10 to Ethernet Expansion (OMX-364) -Applicable since unit version 2.09.510."
]
],
[
"201305280126Z",
[
"DESCRIPTION",
"-v1.26 -Fixed incorrect SYNTAX for sysCharMask (OMX-328). -Applicable since unit version 2.09.380."
]
],
[
"201305100125Z",
[
"DESCRIPTION",
"-v1.25 -Fixed incorrect SYNTAX statements for various objects (OMX-314). -Applicable since unit version 2.09.380."
]
],
[
"201303150124Z",
[
"DESCRIPTION",
"-v1.24 -Renamed sysLocation branch to sysLoc (OMX-198). -Applicable since unit version 2.09.240."
]
],
[
"201302060123Z",
[
"DESCRIPTION",
"-v1.23 -Added ex10 branch. -Renamed telnet* objects. -Applicable since unit version 2.09.240."
]
],
[
"201301140122Z",
[
"DESCRIPTION",
"-v1.22 -Added evReset branch and associated notification (OMX-83). -Applicable since unit version 2.09.220."
]
],
[
"201211260121Z",
[
"DESCRIPTION",
"-v1.21 -Fixed backwards pppRoutingEnable/ethRoutingEnable comments. (BN 4620)"
]
],
[
"201208220120Z",
[
"DESCRIPTION",
"-v1.20 -Added additional AC power monitor items."
]
],
[
"201207090119Z",
[
"DESCRIPTION",
"-v1.19 -Removed wirelessBand object. -Removed secSSH objects."
]
],
[
"201206120118Z",
[
"DESCRIPTION",
"-v1.18 -Removed user credentials objects. -Added combined power distributor status objects."
]
],
[
"201204090117Z",
[
"DESCRIPTION",
"-v1.17 -Added eth2WanRoutingEnable object."
]
],
[
"201204050116Z",
[
"DESCRIPTION",
"-v1.16 -Added combined eventsensor status objects."
]
],
[
"201203060115Z",
[
"DESCRIPTION",
"-v1.15 -Added objects and trap definitions for fuel sensor and AC power monitor."
]
],
[
"201112050900Z",
[
"DESCRIPTION",
"-v1.14 -Added s571StockScriptTrap notification definition."
]
],
[
"201110240900Z",
[
"DESCRIPTION",
"-v1.13 -Added s571StockLoadSheddingTrap notification definition."
]
],
[
"201108080900Z",
[
"DESCRIPTION",
"-v1.12 -Added s571StockOutputTrap notification definition."
]
],
[
"201108010900Z",
[
"DESCRIPTION",
"-v1.11 -Added evMgmtReprocess object."
]
],
[
"201107200900Z",
[
"DESCRIPTION",
"-v1.10 -Added aisgStatus branch."
]
],
[
"201107080900Z",
[
"DESCRIPTION",
"-v1.09 -Added wirelessModemStatus branch."
]
],
[
"201101050900Z",
[
"DESCRIPTION",
"-v1.08 -Added espcCCNormalThreshold object."
]
],
[
"201012010900Z",
[
"DESCRIPTION",
"-v1.07 -Added support for PowerBoss external power distributors. This is in the pdNextGen object branch which also supports the internal power distributor of the SiteBoss 571. The old SNMP support for the internal power distributor is kept in the older sub-branches of the powerDistributionStatus branch (pdConfig, pdMain, pdOutput). The idea behind the pdNextGen object branch is that there are 31 items for power monitoring and alarming, and these items are organized in a double-indexed SNMP table object: the first index is for the power distributor (and has the same numbering scheme as an EventSensor -- like esIndexES, but is called pdnIndexPD), and the second index is the power output to which the item applies (or just '1' if the item is not specific to a particular power output). E.g., to read the main current of the internal power distributor, you can use the old object (pdMainCurrentValue.0) or you can use the new object (pdnMainCurrentValue.200.1). To read the fuse event state of power output number 8 on the power distributor (PowerBoss) at index 2, read pdnOutputFuseInEventState.2.8."
]
],
[
"201011030900Z",
[
"DESCRIPTION",
"-v1.06 -Changed deadband, threshold, and current values for temperature sensors from integer to floating-point type. This means the SNMP object type for the temperature settings (deadbands and thresholds) changed from Integer32 to DisplayString. -Fixed bug where SNMP integer range defined in the MIB for trapIncludedValue was 16-bit instead of 32-bit."
]
],
[
"201008240900Z",
[
"DESCRIPTION",
"-v1.05 -Fixed bug where some stock traps had too few varbinds declared. -Removed useless trap definitions."
]
],
[
"201003170900Z",
[
"DESCRIPTION",
"-v1.04 -Removed useless object consoleInlineHsk. -Added asset management object branch. -Added altitude location object. -Removed all obsolete switch references, made everything consistent on outputs (relay outputs or power outputs). -Added threshold objects for power distribution sensors. -Added pdOutputCurrentValue object. -Fixed description for pdOutputCurrentInEventState."
]
],
[
"201001190900Z",
[
"DESCRIPTION",
"-v1.03 -Increased range for esPointValueInt"
]
],
[
"200910080900Z",
[
"DESCRIPTION",
"-v1.02 -Incremental pre-release changes"
]
],
[
"200910050900Z",
[
"DESCRIPTION",
"-v1.01 -Incremental pre-release changes"
]
],
[
"200909170900Z",
[
"DESCRIPTION",
"-v1.00 -Initial version."
]
]
]
]
]
}Vendor MIB copy from the LibreNMS archive.
Module: SITEBOSS-571-STD-MIB
See published definition above
{'SNMPv2-TC': ['DisplayString'], 'SNMPv2-SMI': ['IpAddress', 'TimeTicks', 'Integer32', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE', 'OBJECT-TYPE'], 'ASENTRIA-ROOT-MIB': ['asentria']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.3052.14.1 | status | 9 | 246 | |
| 1.3.6.1.4.1.3052.14.2 | config | 13 | 1047 | |
| 1.3.6.1.4.1.3052.14.3 | productIds | 10 | 10 | |
| 1.3.6.1.4.1.3052.14.4 | keyInterface | 0 | 0 | |
| 1.3.6.1.4.1.3052.14.110 | s571StockContactClosureTrap | 0 | 0 | |
| 1.3.6.1.4.1.3052.14.120 | s571StockTempTrap | 0 | 0 | |
| 1.3.6.1.4.1.3052.14.130 | s571StockHumidityTrap | 0 | 0 | |
| 1.3.6.1.4.1.3052.14.140 | s571StockAnalogTrap | 0 | 0 | |
| 1.3.6.1.4.1.3052.14.150 | s571StockOutputTrap | 0 | 0 | |
| 1.3.6.1.4.1.3052.14.180 | s571StockPDCurrentTrap | 0 | 0 | |
| 1.3.6.1.4.1.3052.14.190 | s571StockPDVoltageTrap | 0 | 0 | |
| 1.3.6.1.4.1.3052.14.210 | s571StockPDFuseTrap | 0 | 0 | |
| 1.3.6.1.4.1.3052.14.503 | s571StockDataAlarmTrap | 0 | 0 | |
| 1.3.6.1.4.1.3052.14.505 | s571StockNoDataAlarmTrap | 0 | 0 | |
| 1.3.6.1.4.1.3052.14.506 | s571StockSchedTrap | 0 | 0 | |
| 1.3.6.1.4.1.3052.14.507 | s571StockImmediateTrap | 0 | 0 | |
| 1.3.6.1.4.1.3052.14.510 | s571StockCTSTrap | 0 | 0 | |
| 1.3.6.1.4.1.3052.14.511 | s571CPEDownTrap | 0 | 0 | |
| 1.3.6.1.4.1.3052.14.515 | s571FuelSensorDisconnectTrap | 0 | 0 | |
| 1.3.6.1.4.1.3052.14.519 | s571FuelSensorVolumeTrap | 0 | 0 | |
| 1.3.6.1.4.1.3052.14.520 | s571ACPowerMonitorAvgVoltageTrap | 0 | 0 | |
| 1.3.6.1.4.1.3052.14.521 | s571ACPowerMonitorAvgCurrentTrap | 0 | 0 | |
| 1.3.6.1.4.1.3052.14.522 | s571ACPowerMonitorFrequencyTrap | 0 | 0 | |
| 1.3.6.1.4.1.3052.14.523 | s571ACPowerMonitorTRPTrap | 0 | 0 | |
| 1.3.6.1.4.1.3052.14.524 | s571ACPowerMonitorDisconnectTrap | 0 | 0 | |
| 1.3.6.1.4.1.3052.14.525 | s571StockLoadSheddingTrap | 0 | 0 | |
| 1.3.6.1.4.1.3052.14.526 | s571StockScriptTrap | 0 | 0 | |
| 1.3.6.1.4.1.3052.14.527 | s571FuelSensorVolumeSuddenChangeTrap | 0 | 0 | |
| 1.3.6.1.4.1.3052.14.528 | s571FuelSensorVolumeSlowChangeTrap | 0 | 0 | |
| 1.3.6.1.4.1.3052.14.540 | s571ACTotalPowerFactorTrap | 0 | 0 | |
| 1.3.6.1.4.1.3052.14.543 | s571ResetTrap | 0 | 0 | |
| 1.3.6.1.4.1.3052.14.1000 | s571UserTrap1000 | 0 | 0 | |
| 1.3.6.1.4.1.3052.14.1001 | s571UserTrap1001 | 0 | 0 | |
| 1.3.6.1.4.1.3052.14.1002 | s571UserTrap1002 | 0 | 0 | |
| 1.3.6.1.4.1.3052.14.1003 | s571UserTrap1003 | 0 | 0 | |
| 1.3.6.1.4.1.3052.14.1004 | s571UserTrap1004 | 0 | 0 | |
| 1.3.6.1.4.1.3052.14.1005 | s571UserTrap1005 | 0 | 0 | |
| 1.3.6.1.4.1.3052.14.1006 | s571UserTrap1006 | 0 | 0 | |
| 1.3.6.1.4.1.3052.14.1007 | s571UserTrap1007 | 0 | 0 | |
| 1.3.6.1.4.1.3052.14.1008 | s571UserTrap1008 | 0 | 0 | |
| 1.3.6.1.4.1.3052.14.1009 | s571UserTrap1009 | 0 | 0 | |
| 1.3.6.1.4.1.3052.14.1010 | s571UserTrap1010 | 0 | 0 | |
| 1.3.6.1.4.1.3052.14.1011 | s571UserTrap1011 | 0 | 0 | |
| 1.3.6.1.4.1.3052.14.1012 | s571UserTrap1012 | 0 | 0 | |
| 1.3.6.1.4.1.3052.14.1013 | s571UserTrap1013 | 0 | 0 | |
| 1.3.6.1.4.1.3052.14.1014 | s571UserTrap1014 | 0 | 0 | |
| 1.3.6.1.4.1.3052.14.1015 | s571UserTrap1015 | 0 | 0 | |
| 1.3.6.1.4.1.3052.14.1016 | s571UserTrap1016 | 0 | 0 | |
| 1.3.6.1.4.1.3052.14.1017 | s571UserTrap1017 | 0 | 0 | |
| 1.3.6.1.4.1.3052.14.1018 | s571UserTrap1018 | 0 | 0 |
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.3052.1 | datalink | 19 | 379 | |
| 1.3.6.1.4.1.3052.3 | dl | 209 | 419 | |
| 1.3.6.1.4.1.3052.4 | sl61 | 211 | 565 | |
| 1.3.6.1.4.1.3052.5 | sl81 | 213 | 571 | |
| 1.3.6.1.4.1.3052.6 | dl150 | 215 | 451 | |
| 1.3.6.1.4.1.3052.7 | dl80 | 215 | 451 | |
| 1.3.6.1.4.1.3052.8 | s570 | 226 | 1390 | |
| 1.3.6.1.4.1.3052.10 | s550 | 5 | 2205 | |
| 1.3.6.1.4.1.3052.12 | s530 | 228 | 1302 | |
| 1.3.6.1.4.1.3052.17 | s450 | 5 | 1489 | |
| 1.3.6.1.4.1.3052.18 | s350 | 5 | 1652 | |
| 1.3.6.1.4.1.3052.20 | s572 | 5 | 1499 | |
| 1.3.6.1.4.1.3052.23 | s360 | 5 | 2239 | |
| 1.3.6.1.4.1.3052.40 | s410, sl10 | 69 | 343 | S410 |
| 1.3.6.1.4.1.3052.41 | s412, sl12 | 63 | 296 | |
| 1.3.6.1.4.1.3052.42 | s420 | 8 | 133 | |
| 1.3.6.1.4.1.3052.43 | s220 | 8 | 133 | |
| 1.3.6.1.4.1.3052.501 | datalinkDbasePfullTrap | 0 | 0 | |
| 1.3.6.1.4.1.3052.502 | datalinkFilePfullTrap | 0 | 0 | |
| 1.3.6.1.4.1.3052.503 | datalinkDataAlarmTrap | 0 | 0 | |
| 1.3.6.1.4.1.3052.504 | datalinkSensorAlarmTrap | 0 | 0 | |
| 1.3.6.1.4.1.3052.505 | datalinkNoDataAlarmTrap | 0 | 0 | |
| 1.3.6.1.4.1.3052.506 | datalinkSchedTrap | 0 | 0 | |
| 1.3.6.1.4.1.3052.507 | datalinkImmediateTrap | 0 | 0 | |
| 1.3.6.1.4.1.3052.509 | datalinkPPPupTrap | 0 | 0 |