OID reference

s571

1.3.6.1.4.1.3052.14

Description

MIB module for managing Asentria SiteBoss 571

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.3052 (asentria, omnitronix)
Node code
14
Node name
s571
Numeric OID
1.3.6.1.4.1.3052.14
URN notation
urn:oid:1.3.6.1.4.1.3052.14
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 3052 14}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) asentria(3052) s571(14)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) omnitronix(3052) s571(14)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) asentria(3052) s571(14)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) omnitronix(3052) s571(14)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) asentria(3052) s571(14)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) omnitronix(3052) s571(14)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) asentria(3052) s571(14)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) omnitronix(3052) s571(14)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) asentria(3052) s571(14)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) omnitronix(3052) s571(14)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) asentria(3052) s571(14)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) omnitronix(3052) s571(14)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) asentria(3052) s571(14)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) omnitronix(3052) s571(14)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) asentria(3052) s571(14)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) omnitronix(3052) s571(14)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/3052/14
  • /ISO/Identified-Organization/6/1/4/1/3052/14
  • /ISO/3/6/1/4/1/3052/14
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/asentria/s571
  • /iso/identified-organization/dod/internet/private/enterprise/omnitronix/s571
  • /iso/identified-organization/dod/internet/private/enterprises/asentria/s571
  • /iso/identified-organization/dod/internet/private/enterprises/omnitronix/s571
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/asentria/s571
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/omnitronix/s571
  • /iso/identified-organization/dod/internet/private/vendor-objects/asentria/s571
  • /iso/identified-organization/dod/internet/private/vendor-objects/omnitronix/s571
  • /iso/org/dod/internet/private/enterprise/asentria/s571
  • /iso/org/dod/internet/private/enterprise/omnitronix/s571
  • /iso/org/dod/internet/private/enterprises/asentria/s571
  • /iso/org/dod/internet/private/enterprises/omnitronix/s571
  • /iso/org/dod/internet/private/ldap-enterprise/asentria/s571
  • /iso/org/dod/internet/private/ldap-enterprise/omnitronix/s571
  • /iso/org/dod/internet/private/vendor-objects/asentria/s571
  • /iso/org/dod/internet/private/vendor-objects/omnitronix/s571
  • Additional combinations skipped.

Available source records contain 2 distinct definitions; some records may not include a definition.

Show 2 published definitions

s571 · unspecified

s571 MODULE-IDENTITY
    LAST-UPDATED "201412110143Z"
    ORGANIZATION "Asentria Corporation"
    CONTACT-INFO
     "Phone:  206-344-8800
      Fax:    206-344-2116
      Email:  support@asentria.com"
    DESCRIPTION
      "MIB module for managing Asentria SiteBoss 571"

    REVISION      "201412110143Z"
    DESCRIPTION
      "-v1.43
       -Changed analog-input fuel sensor objects from Integer32 to DisplayString (OMX-1177).
       -Added missing ipv6DefaultRouter object (OMX-1175).
       -Applicable since unit version 2.10.580."

    REVISION      "201410160142Z"
    DESCRIPTION
      "-v1.42
       -Added espcAIDisplayFormat object (OMX-1112).
       -Removed espcAIPolarity, espcAIConvHighSign, espcAIConvLowSign objects (OMX-1113).
       -Applicable since unit version 2.10.460."

    REVISION      "201410030141Z"
    DESCRIPTION
      "-v1.41
       -Changed analog input objects from Integer32 to DisplayString.
       -Applicable since unit version 2.10.460."

    REVISION      "201408140140Z"
    DESCRIPTION
      "-v1.40
       -Fixed description for wirelessConnIP objects (OMX-1061).
       -Applicable since unit version 2.10.390."

    REVISION      "201407030139Z"
    DESCRIPTION
      "-v1.39
       -Fixed wirelessIdleTimeout (OMX-1037).
       -Fixed CPE status objects (OMX-1036).
       -Applicable since unit version 2.10.390."

    REVISION      "201406240138Z"
    DESCRIPTION
      "-v1.38
       -Fixed CPE status objects.
       -Applicable since unit version 2.10.340."

    REVISION      "201405290137Z"
    DESCRIPTION
      "-v1.37
       -Added various missing objects (OMX-751).
       -Added CPE objects (OMX-162).
       -Applicable since unit version 2.10.320."

    REVISION      "201404110136Z"
    DESCRIPTION
      "-v1.36
       -Clarified relay and power output function and documentation (OMX-926).
       -Applicable since unit version 2.10.300."

    REVISION      "201401170135Z"
    DESCRIPTION
      "-v1.35
       -Added IPv6 objects (OMX-705).
       -Added power distribution objects (powerDistributionStatus branch) (OMX-708).
       -Fixed ipRestrictionMask wrong type (OMX-743).
       -Added ftpPushPermissions (OMX-737).
       -Added snmpProxy objects (OMX-747).
       -Applicable since unit version 2.10.150."

    REVISION      "201312040134Z"
    DESCRIPTION
      "-v1.34
       -Added fsGenEnable (OMX-661).
       -Applicable since unit version 2.10.110."

    REVISION      "201309040133Z"
    DESCRIPTION
      "-v1.33
       -Added pdSystemCurrent and pdSystemPower objects (OMX-527).
       -Added pdnDeviceCurrentValue and pdnDeviceCurrentValueStr objects (OMX-528).
       -Applicable since unit version 2.09.626."

    REVISION      "201308010132Z"
    DESCRIPTION
      "-v1.32
       -Added missing trapEventTypeNumber available values in description (OMX-437).
       -Applicable since unit version 2.09.560."

    REVISION      "201307170131Z"
    DESCRIPTION
      "-v1.31
       -Corrected snmpPBufferAllPeriod object.
       -Applicable since unit version 2.09.560."

    REVISION      "201307020130Z"
    DESCRIPTION
      "-v1.30
       -Added snmpPoll objects (OMX-394).
       -Applicable since unit version 2.09.560."

    REVISION      "201306280129Z"
    DESCRIPTION
      "-v1.29
       -Removed Ethernet Expansion card objects.
       -Applicable since unit version 2.09.540."

    REVISION      "201306130128Z"
    DESCRIPTION
      "-v1.28
       -Added sysFileTransfer and sysUpdate objects. (OMX-42)
       -Applicable since unit version 2.09.520."

    REVISION      "201306120127Z"
    DESCRIPTION
      "-v1.27
       -Renamed EX10 to Ethernet Expansion (OMX-364)
       -Applicable since unit version 2.09.510."

    REVISION      "201305280126Z"
    DESCRIPTION
      "-v1.26
       -Fixed incorrect SYNTAX for sysCharMask (OMX-328).
       -Applicable since unit version 2.09.380."

    REVISION      "201305100125Z"
    DESCRIPTION
      "-v1.25
       -Fixed incorrect SYNTAX statements for various objects (OMX-314).
       -Applicable since unit version 2.09.380."

    REVISION      "201303150124Z"
    DESCRIPTION
      "-v1.24
       -Renamed sysLocation branch to sysLoc (OMX-198).
       -Applicable since unit version 2.09.240."

    REVISION      "201302060123Z"
    DESCRIPTION
      "-v1.23
       -Added ex10 branch.
       -Renamed telnet* objects.
       -Applicable since unit version 2.09.240."

    REVISION      "201301140122Z"
    DESCRIPTION
      "-v1.22
       -Added evReset branch and associated notification (OMX-83).
       -Applicable since unit version 2.09.220."

    REVISION      "201211260121Z"
    DESCRIPTION
      "-v1.21
       -Fixed backwards pppRoutingEnable/ethRoutingEnable comments.  (BN 4620)"

    REVISION      "201208220120Z"
    DESCRIPTION
      "-v1.20
       -Added additional AC power monitor items."

    REVISION      "201207090119Z"
    DESCRIPTION
      "-v1.19
       -Removed wirelessBand object.
       -Removed secSSH objects."

    REVISION      "201206120118Z"
    DESCRIPTION
      "-v1.18
       -Removed user credentials objects.
       -Added combined power distributor status objects."

    REVISION      "201204090117Z"
    DESCRIPTION
      "-v1.17
       -Added eth2WanRoutingEnable object."

    REVISION      "201204050116Z"
    DESCRIPTION
      "-v1.16
       -Added combined eventsensor status objects."

    REVISION      "201203060115Z"
    DESCRIPTION
      "-v1.15
       -Added objects and trap definitions for fuel sensor and AC power monitor."

    REVISION      "201112050900Z"
    DESCRIPTION
      "-v1.14
       -Added s571StockScriptTrap notification definition."

    REVISION      "201110240900Z"
    DESCRIPTION
      "-v1.13
       -Added s571StockLoadSheddingTrap notification definition."

    REVISION      "201108080900Z"
    DESCRIPTION
      "-v1.12
       -Added s571StockOutputTrap notification definition."

    REVISION      "201108010900Z"
    DESCRIPTION
      "-v1.11
       -Added evMgmtReprocess object."

    REVISION      "201107200900Z"
    DESCRIPTION
      "-v1.10
       -Added aisgStatus branch."

    REVISION      "201107080900Z"
    DESCRIPTION
      "-v1.09
       -Added wirelessModemStatus branch."

    REVISION      "201101050900Z"
    DESCRIPTION
      "-v1.08
       -Added espcCCNormalThreshold object."

    REVISION      "201012010900Z"
    DESCRIPTION
      "-v1.07
       -Added support for PowerBoss external power distributors.  This is in the
       pdNextGen object branch which also supports the internal power distributor
       of the SiteBoss 571.  The old SNMP support for the internal power
       distributor is kept in the older sub-branches of the powerDistributionStatus
       branch (pdConfig, pdMain, pdOutput).  The idea behind the pdNextGen object
       branch is that there are 31 items for power monitoring and alarming, and
       these items are organized in a double-indexed SNMP table object: the first
       index is for the power distributor (and has the same numbering scheme as an
       EventSensor  -- like esIndexES, but is called pdnIndexPD), and the second
       index is the power output to which the item applies (or just '1' if the item
       is not specific to a particular power output).  E.g., to read the main
       current of the internal power distributor, you can use the old object
       (pdMainCurrentValue.0) or you can use the new object
       (pdnMainCurrentValue.200.1).  To read the fuse event state of power output
       number 8 on the power distributor (PowerBoss) at index 2, read
       pdnOutputFuseInEventState.2.8."

    REVISION      "201011030900Z"
    DESCRIPTION
      "-v1.06
       -Changed deadband, threshold, and current values for temperature
       sensors from integer to floating-point type.  This means the
       SNMP object type for the temperature settings (deadbands and
       thresholds) changed from Integer32 to DisplayString.
       -Fixed bug where SNMP integer range defined in the MIB for
       trapIncludedValue was 16-bit instead of 32-bit."

    REVISION      "201008240900Z"
    DESCRIPTION
      "-v1.05
       -Fixed bug where some stock traps had too few varbinds declared.
       -Removed useless trap definitions."

    REVISION      "201003170900Z"
    DESCRIPTION
      "-v1.04
       -Removed useless object consoleInlineHsk.
       -Added asset management object branch.
       -Added altitude location object.
       -Removed all obsolete switch references, made everything consistent
        on outputs (relay outputs or power outputs).
       -Added threshold objects for power distribution sensors.
       -Added pdOutputCurrentValue object.
       -Fixed description for pdOutputCurrentInEventState."

    REVISION      "201001190900Z"
    DESCRIPTION
      "-v1.03
       -Increased range for esPointValueInt"

    REVISION      "200910080900Z"
    DESCRIPTION
      "-v1.02
       -Incremental pre-release changes"

    REVISION      "200910050900Z"
    DESCRIPTION
      "-v1.01
       -Incremental pre-release changes"

    REVISION      "200909170900Z"
    DESCRIPTION
      "-v1.00
       -Initial version."

    ::= { asentria 14 }

s571 · unspecified

s571 MODULE-IDENTITY
    LAST-UPDATED "201412300144Z"
    ORGANIZATION "Asentria Corporation"
    CONTACT-INFO
     "Phone:  206-344-8800
      Fax:    206-344-2116
      Email:  support@asentria.com"
    DESCRIPTION
      "MIB module for managing Asentria SiteBoss 571"

    REVISION      "201412300144Z"
    DESCRIPTION
      "-v1.44
       -Removed wirelessPIN and scSecret objects (OMX-1064).
       -Applicable since unit version 2.10.610."

    REVISION      "201412110143Z"
    DESCRIPTION
      "-v1.43
       -Changed analog-input fuel sensor objects from Integer32 to DisplayString (OMX-1177).
       -Added missing ipv6DefaultRouter object (OMX-1175).
       -Applicable since unit version 2.10.580."

    REVISION      "201410160142Z"
    DESCRIPTION
      "-v1.42
       -Added espcAIDisplayFormat object (OMX-1112).
       -Removed espcAIPolarity, espcAIConvHighSign, espcAIConvLowSign objects (OMX-1113).
       -Applicable since unit version 2.10.460."

    REVISION      "201410030141Z"
    DESCRIPTION
      "-v1.41
       -Changed analog input objects from Integer32 to DisplayString.
       -Applicable since unit version 2.10.460."

    REVISION      "201408140140Z"
    DESCRIPTION
      "-v1.40
       -Fixed description for wirelessConnIP objects (OMX-1061).
       -Applicable since unit version 2.10.390."

    REVISION      "201407030139Z"
    DESCRIPTION
      "-v1.39
       -Fixed wirelessIdleTimeout (OMX-1037).
       -Fixed CPE status objects (OMX-1036).
       -Applicable since unit version 2.10.390."

    REVISION      "201406240138Z"
    DESCRIPTION
      "-v1.38
       -Fixed CPE status objects.
       -Applicable since unit version 2.10.340."

    REVISION      "201405290137Z"
    DESCRIPTION
      "-v1.37
       -Added various missing objects (OMX-751).
       -Added CPE objects (OMX-162).
       -Applicable since unit version 2.10.320."

    REVISION      "201404110136Z"
    DESCRIPTION
      "-v1.36
       -Clarified relay and power output function and documentation (OMX-926).
       -Applicable since unit version 2.10.300."

    REVISION      "201401170135Z"
    DESCRIPTION
      "-v1.35
       -Added IPv6 objects (OMX-705).
       -Added power distribution objects (powerDistributionStatus branch) (OMX-708).
       -Fixed ipRestrictionMask wrong type (OMX-743).
       -Added ftpPushPermissions (OMX-737).
       -Added snmpProxy objects (OMX-747).
       -Applicable since unit version 2.10.150."

    REVISION      "201312040134Z"
    DESCRIPTION
      "-v1.34
       -Added fsGenEnable (OMX-661).
       -Applicable since unit version 2.10.110."

    REVISION      "201309040133Z"
    DESCRIPTION
      "-v1.33
       -Added pdSystemCurrent and pdSystemPower objects (OMX-527).
       -Added pdnDeviceCurrentValue and pdnDeviceCurrentValueStr objects (OMX-528).
       -Applicable since unit version 2.09.626."

    REVISION      "201308010132Z"
    DESCRIPTION
      "-v1.32
       -Added missing trapEventTypeNumber available values in description (OMX-437).
       -Applicable since unit version 2.09.560."

    REVISION      "201307170131Z"
    DESCRIPTION
      "-v1.31
       -Corrected snmpPBufferAllPeriod object.
       -Applicable since unit version 2.09.560."

    REVISION      "201307020130Z"
    DESCRIPTION
      "-v1.30
       -Added snmpPoll objects (OMX-394).
       -Applicable since unit version 2.09.560."

    REVISION      "201306280129Z"
    DESCRIPTION
      "-v1.29
       -Removed Ethernet Expansion card objects.
       -Applicable since unit version 2.09.540."

    REVISION      "201306130128Z"
    DESCRIPTION
      "-v1.28
       -Added sysFileTransfer and sysUpdate objects. (OMX-42)
       -Applicable since unit version 2.09.520."

    REVISION      "201306120127Z"
    DESCRIPTION
      "-v1.27
       -Renamed EX10 to Ethernet Expansion (OMX-364)
       -Applicable since unit version 2.09.510."

    REVISION      "201305280126Z"
    DESCRIPTION
      "-v1.26
       -Fixed incorrect SYNTAX for sysCharMask (OMX-328).
       -Applicable since unit version 2.09.380."

    REVISION      "201305100125Z"
    DESCRIPTION
      "-v1.25
       -Fixed incorrect SYNTAX statements for various objects (OMX-314).
       -Applicable since unit version 2.09.380."

    REVISION      "201303150124Z"
    DESCRIPTION
      "-v1.24
       -Renamed sysLocation branch to sysLoc (OMX-198).
       -Applicable since unit version 2.09.240."

    REVISION      "201302060123Z"
    DESCRIPTION
      "-v1.23
       -Added ex10 branch.
       -Renamed telnet* objects.
       -Applicable since unit version 2.09.240."

    REVISION      "201301140122Z"
    DESCRIPTION
      "-v1.22
       -Added evReset branch and associated notification (OMX-83).
       -Applicable since unit version 2.09.220."

    REVISION      "201211260121Z"
    DESCRIPTION
      "-v1.21
       -Fixed backwards pppRoutingEnable/ethRoutingEnable comments.  (BN 4620)"

    REVISION      "201208220120Z"
    DESCRIPTION
      "-v1.20
       -Added additional AC power monitor items."

    REVISION      "201207090119Z"
    DESCRIPTION
      "-v1.19
       -Removed wirelessBand object.
       -Removed secSSH objects."

    REVISION      "201206120118Z"
    DESCRIPTION
      "-v1.18
       -Removed user credentials objects.
       -Added combined power distributor status objects."

    REVISION      "201204090117Z"
    DESCRIPTION
      "-v1.17
       -Added eth2WanRoutingEnable object."

    REVISION      "201204050116Z"
    DESCRIPTION
      "-v1.16
       -Added combined eventsensor status objects."

    REVISION      "201203060115Z"
    DESCRIPTION
      "-v1.15
       -Added objects and trap definitions for fuel sensor and AC power monitor."

    REVISION      "201112050900Z"
    DESCRIPTION
      "-v1.14
       -Added s571StockScriptTrap notification definition."

    REVISION      "201110240900Z"
    DESCRIPTION
      "-v1.13
       -Added s571StockLoadSheddingTrap notification definition."

    REVISION      "201108080900Z"
    DESCRIPTION
      "-v1.12
       -Added s571StockOutputTrap notification definition."

    REVISION      "201108010900Z"
    DESCRIPTION
      "-v1.11
       -Added evMgmtReprocess object."

    REVISION      "201107200900Z"
    DESCRIPTION
      "-v1.10
       -Added aisgStatus branch."

    REVISION      "201107080900Z"
    DESCRIPTION
      "-v1.09
       -Added wirelessModemStatus branch."

    REVISION      "201101050900Z"
    DESCRIPTION
      "-v1.08
       -Added espcCCNormalThreshold object."

    REVISION      "201012010900Z"
    DESCRIPTION
      "-v1.07
       -Added support for PowerBoss external power distributors.  This is in the
       pdNextGen object branch which also supports the internal power distributor
       of the SiteBoss 571.  The old SNMP support for the internal power
       distributor is kept in the older sub-branches of the powerDistributionStatus
       branch (pdConfig, pdMain, pdOutput).  The idea behind the pdNextGen object
       branch is that there are 31 items for power monitoring and alarming, and
       these items are organized in a double-indexed SNMP table object: the first
       index is for the power distributor (and has the same numbering scheme as an
       EventSensor  -- like esIndexES, but is called pdnIndexPD), and the second
       index is the power output to which the item applies (or just '1' if the item
       is not specific to a particular power output).  E.g., to read the main
       current of the internal power distributor, you can use the old object
       (pdMainCurrentValue.0) or you can use the new object
       (pdnMainCurrentValue.200.1).  To read the fuse event state of power output
       number 8 on the power distributor (PowerBoss) at index 2, read
       pdnOutputFuseInEventState.2.8."

    REVISION      "201011030900Z"
    DESCRIPTION
      "-v1.06
       -Changed deadband, threshold, and current values for temperature
       sensors from integer to floating-point type.  This means the
       SNMP object type for the temperature settings (deadbands and
       thresholds) changed from Integer32 to DisplayString.
       -Fixed bug where SNMP integer range defined in the MIB for
       trapIncludedValue was 16-bit instead of 32-bit."

    REVISION      "201008240900Z"
    DESCRIPTION
      "-v1.05
       -Fixed bug where some stock traps had too few varbinds declared.
       -Removed useless trap definitions."

    REVISION      "201003170900Z"
    DESCRIPTION
      "-v1.04
       -Removed useless object consoleInlineHsk.
       -Added asset management object branch.
       -Added altitude location object.
       -Removed all obsolete switch references, made everything consistent
        on outputs (relay outputs or power outputs).
       -Added threshold objects for power distribution sensors.
       -Added pdOutputCurrentValue object.
       -Fixed description for pdOutputCurrentInEventState."

    REVISION      "201001190900Z"
    DESCRIPTION
      "-v1.03
       -Increased range for esPointValueInt"

    REVISION      "200910080900Z"
    DESCRIPTION
      "-v1.02
       -Incremental pre-release changes"

    REVISION      "200910050900Z"
    DESCRIPTION
      "-v1.01
       -Incremental pre-release changes"

    REVISION      "200909170900Z"
    DESCRIPTION
      "-v1.00
       -Initial version."

    ::= { asentria 14 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

MIB module for managing Asentria SiteBoss 571

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 2 matching source records

Evidence

Source records

2 records

Matching descriptions are grouped; representative source files are shown for each definition.

Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)2 records · 2 sources

Description 1

s571 · unspecifiedMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: unspecified.

Names: s571

Technical details
{
  "smi_kind": "MODULE-IDENTITY",
  "definition": [
    "s571",
    "MODULE-IDENTITY",
    "LAST-UPDATED",
    [
      "literal",
      "223230313431323131303134335a22"
    ],
    "ORGANIZATION",
    "\"Asentria Corporation\"",
    "CONTACT-INFO",
    "\"Phone: 206-344-8800 Fax: 206-344-2116 Email: support@asentria.com\"",
    "DESCRIPTION",
    "\"MIB module for managing Asentria SiteBoss 571\"",
    "REVISION",
    [
      "literal",
      "223230313431323131303134335a22"
    ],
    "DESCRIPTION",
    "\"-v1.43 -Changed analog-input fuel sensor objects from Integer32 to DisplayString (OMX-1177). -Added missing ipv6DefaultRouter object (OMX-1175). -Applicable since unit version 2.10.580.\"",
    "REVISION",
    [
      "literal",
      "223230313431303136303134325a22"
    ],
    "DESCRIPTION",
    "\"-v1.42 -Added espcAIDisplayFormat object (OMX-1112). -Removed espcAIPolarity, espcAIConvHighSign, espcAIConvLowSign objects (OMX-1113). -Applicable since unit version 2.10.460.\"",
    "REVISION",
    [
      "literal",
      "223230313431303033303134315a22"
    ],
    "DESCRIPTION",
    "\"-v1.41 -Changed analog input objects from Integer32 to DisplayString. -Applicable since unit version 2.10.460.\"",
    "REVISION",
    [
      "literal",
      "223230313430383134303134305a22"
    ],
    "DESCRIPTION",
    "\"-v1.40 -Fixed description for wirelessConnIP objects (OMX-1061). -Applicable since unit version 2.10.390.\"",
    "REVISION",
    [
      "literal",
      "223230313430373033303133395a22"
    ],
    "DESCRIPTION",
    "\"-v1.39 -Fixed wirelessIdleTimeout (OMX-1037). -Fixed CPE status objects (OMX-1036). -Applicable since unit version 2.10.390.\"",
    "REVISION",
    [
      "literal",
      "223230313430363234303133385a22"
    ],
    "DESCRIPTION",
    "\"-v1.38 -Fixed CPE status objects. -Applicable since unit version 2.10.340.\"",
    "REVISION",
    [
      "literal",
      "223230313430353239303133375a22"
    ],
    "DESCRIPTION",
    "\"-v1.37 -Added various missing objects (OMX-751). -Added CPE objects (OMX-162). -Applicable since unit version 2.10.320.\"",
    "REVISION",
    [
      "literal",
      "223230313430343131303133365a22"
    ],
    "DESCRIPTION",
    "\"-v1.36 -Clarified relay and power output function and documentation (OMX-926). -Applicable since unit version 2.10.300.\"",
    "REVISION",
    [
      "literal",
      "223230313430313137303133355a22"
    ],
    "DESCRIPTION",
    "\"-v1.35 -Added IPv6 objects (OMX-705). -Added power distribution objects (powerDistributionStatus branch) (OMX-708). -Fixed ipRestrictionMask wrong type (OMX-743). -Added ftpPushPermissions (OMX-737). -Added snmpProxy objects (OMX-747). -Applicable since unit version 2.10.150.\"",
    "REVISION",
    [
      "literal",
      "223230313331323034303133345a22"
    ],
    "DESCRIPTION",
    "\"-v1.34 -Added fsGenEnable (OMX-661). -Applicable since unit version 2.10.110.\"",
    "REVISION",
    [
      "literal",
      "223230313330393034303133335a22"
    ],
    "DESCRIPTION",
    "\"-v1.33 -Added pdSystemCurrent and pdSystemPower objects (OMX-527). -Added pdnDeviceCurrentValue and pdnDeviceCurrentValueStr objects (OMX-528). -Applicable since unit version 2.09.626.\"",
    "REVISION",
    [
      "literal",
      "223230313330383031303133325a22"
    ],
    "DESCRIPTION",
    "\"-v1.32 -Added missing trapEventTypeNumber available values in description (OMX-437). -Applicable since unit version 2.09.560.\"",
    "REVISION",
    [
      "literal",
      "223230313330373137303133315a22"
    ],
    "DESCRIPTION",
    "\"-v1.31 -Corrected snmpPBufferAllPeriod object. -Applicable since unit version 2.09.560.\"",
    "REVISION",
    [
      "literal",
      "223230313330373032303133305a22"
    ],
    "DESCRIPTION",
    "\"-v1.30 -Added snmpPoll objects (OMX-394). -Applicable since unit version 2.09.560.\"",
    "REVISION",
    [
      "literal",
      "223230313330363238303132395a22"
    ],
    "DESCRIPTION",
    "\"-v1.29 -Removed Ethernet Expansion card objects. -Applicable since unit version 2.09.540.\"",
    "REVISION",
    [
      "literal",
      "223230313330363133303132385a22"
    ],
    "DESCRIPTION",
    "\"-v1.28 -Added sysFileTransfer and sysUpdate objects. (OMX-42) -Applicable since unit version 2.09.520.\"",
    "REVISION",
    [
      "literal",
      "223230313330363132303132375a22"
    ],
    "DESCRIPTION",
    "\"-v1.27 -Renamed EX10 to Ethernet Expansion (OMX-364) -Applicable since unit version 2.09.510.\"",
    "REVISION",
    [
      "literal",
      "223230313330353238303132365a22"
    ],
    "DESCRIPTION",
    "\"-v1.26 -Fixed incorrect SYNTAX for sysCharMask (OMX-328). -Applicable since unit version 2.09.380.\"",
    "REVISION",
    [
      "literal",
      "223230313330353130303132355a22"
    ],
    "DESCRIPTION",
    "\"-v1.25 -Fixed incorrect SYNTAX statements for various objects (OMX-314). -Applicable since unit version 2.09.380.\"",
    "REVISION",
    [
      "literal",
      "223230313330333135303132345a22"
    ],
    "DESCRIPTION",
    "\"-v1.24 -Renamed sysLocation branch to sysLoc (OMX-198). -Applicable since unit version 2.09.240.\"",
    "REVISION",
    [
      "literal",
      "223230313330323036303132335a22"
    ],
    "DESCRIPTION",
    "\"-v1.23 -Added ex10 branch. -Renamed telnet* objects. -Applicable since unit version 2.09.240.\"",
    "REVISION",
    [
      "literal",
      "223230313330313134303132325a22"
    ],
    "DESCRIPTION",
    "\"-v1.22 -Added evReset branch and associated notification (OMX-83). -Applicable since unit version 2.09.220.\"",
    "REVISION",
    [
      "literal",
      "223230313231313236303132315a22"
    ],
    "DESCRIPTION",
    "\"-v1.21 -Fixed backwards pppRoutingEnable/ethRoutingEnable comments. (BN 4620)\"",
    "REVISION",
    [
      "literal",
      "223230313230383232303132305a22"
    ],
    "DESCRIPTION",
    "\"-v1.20 -Added additional AC power monitor items.\"",
    "REVISION",
    [
      "literal",
      "223230313230373039303131395a22"
    ],
    "DESCRIPTION",
    "\"-v1.19 -Removed wirelessBand object. -Removed secSSH objects.\"",
    "REVISION",
    [
      "literal",
      "223230313230363132303131385a22"
    ],
    "DESCRIPTION",
    "\"-v1.18 -Removed user credentials objects. -Added combined power distributor status objects.\"",
    "REVISION",
    [
      "literal",
      "223230313230343039303131375a22"
    ],
    "DESCRIPTION",
    "\"-v1.17 -Added eth2WanRoutingEnable object.\"",
    "REVISION",
    [
      "literal",
      "223230313230343035303131365a22"
    ],
    "DESCRIPTION",
    "\"-v1.16 -Added combined eventsensor status objects.\"",
    "REVISION",
    [
      "literal",
      "223230313230333036303131355a22"
    ],
    "DESCRIPTION",
    "\"-v1.15 -Added objects and trap definitions for fuel sensor and AC power monitor.\"",
    "REVISION",
    [
      "literal",
      "223230313131323035303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.14 -Added s571StockScriptTrap notification definition.\"",
    "REVISION",
    [
      "literal",
      "223230313131303234303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.13 -Added s571StockLoadSheddingTrap notification definition.\"",
    "REVISION",
    [
      "literal",
      "223230313130383038303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.12 -Added s571StockOutputTrap notification definition.\"",
    "REVISION",
    [
      "literal",
      "223230313130383031303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.11 -Added evMgmtReprocess object.\"",
    "REVISION",
    [
      "literal",
      "223230313130373230303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.10 -Added aisgStatus branch.\"",
    "REVISION",
    [
      "literal",
      "223230313130373038303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.09 -Added wirelessModemStatus branch.\"",
    "REVISION",
    [
      "literal",
      "223230313130313035303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.08 -Added espcCCNormalThreshold object.\"",
    "REVISION",
    [
      "literal",
      "223230313031323031303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.07 -Added support for PowerBoss external power distributors. This is in the pdNextGen object branch which also supports the internal power distributor of the SiteBoss 571. The old SNMP support for the internal power distributor is kept in the older sub-branches of the powerDistributionStatus branch (pdConfig, pdMain, pdOutput). The idea behind the pdNextGen object branch is that there are 31 items for power monitoring and alarming, and these items are organized in a double-indexed SNMP table object: the first index is for the power distributor (and has the same numbering scheme as an EventSensor -- like esIndexES, but is called pdnIndexPD), and the second index is the power output to which the item applies (or just '1' if the item is not specific to a particular power output). E.g., to read the main current of the internal power distributor, you can use the old object (pdMainCurrentValue.0) or you can use the new object (pdnMainCurrentValue.200.1). To read the fuse event state of power output number 8 on the power distributor (PowerBoss) at index 2, read pdnOutputFuseInEventState.2.8.\"",
    "REVISION",
    [
      "literal",
      "223230313031313033303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.06 -Changed deadband, threshold, and current values for temperature sensors from integer to floating-point type. This means the SNMP object type for the temperature settings (deadbands and thresholds) changed from Integer32 to DisplayString. -Fixed bug where SNMP integer range defined in the MIB for trapIncludedValue was 16-bit instead of 32-bit.\"",
    "REVISION",
    [
      "literal",
      "223230313030383234303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.05 -Fixed bug where some stock traps had too few varbinds declared. -Removed useless trap definitions.\"",
    "REVISION",
    [
      "literal",
      "223230313030333137303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.04 -Removed useless object consoleInlineHsk. -Added asset management object branch. -Added altitude location object. -Removed all obsolete switch references, made everything consistent on outputs (relay outputs or power outputs). -Added threshold objects for power distribution sensors. -Added pdOutputCurrentValue object. -Fixed description for pdOutputCurrentInEventState.\"",
    "REVISION",
    [
      "literal",
      "223230313030313139303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.03 -Increased range for esPointValueInt\"",
    "REVISION",
    [
      "literal",
      "223230303931303038303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.02 -Incremental pre-release changes\"",
    "REVISION",
    [
      "literal",
      "223230303931303035303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.01 -Incremental pre-release changes\"",
    "REVISION",
    [
      "literal",
      "223230303930393137303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.00 -Initial version.\"",
    "::=",
    "{",
    "asentria",
    "14",
    "}"
  ],
  "syntax_tree": [
    [
      "LAST-UPDATED",
      "201412110143Z"
    ],
    [
      "ORGANIZATION",
      "Asentria Corporation"
    ],
    [
      "CONTACT-INFO",
      "Phone: 206-344-8800 Fax: 206-344-2116 Email: support@asentria.com"
    ],
    [
      "DESCRIPTION",
      "MIB module for managing Asentria SiteBoss 571"
    ],
    [
      "Revisions",
      [
        [
          "201412110143Z",
          [
            "DESCRIPTION",
            "-v1.43 -Changed analog-input fuel sensor objects from Integer32 to DisplayString (OMX-1177). -Added missing ipv6DefaultRouter object (OMX-1175). -Applicable since unit version 2.10.580."
          ]
        ],
        [
          "201410160142Z",
          [
            "DESCRIPTION",
            "-v1.42 -Added espcAIDisplayFormat object (OMX-1112). -Removed espcAIPolarity, espcAIConvHighSign, espcAIConvLowSign objects (OMX-1113). -Applicable since unit version 2.10.460."
          ]
        ],
        [
          "201410030141Z",
          [
            "DESCRIPTION",
            "-v1.41 -Changed analog input objects from Integer32 to DisplayString. -Applicable since unit version 2.10.460."
          ]
        ],
        [
          "201408140140Z",
          [
            "DESCRIPTION",
            "-v1.40 -Fixed description for wirelessConnIP objects (OMX-1061). -Applicable since unit version 2.10.390."
          ]
        ],
        [
          "201407030139Z",
          [
            "DESCRIPTION",
            "-v1.39 -Fixed wirelessIdleTimeout (OMX-1037). -Fixed CPE status objects (OMX-1036). -Applicable since unit version 2.10.390."
          ]
        ],
        [
          "201406240138Z",
          [
            "DESCRIPTION",
            "-v1.38 -Fixed CPE status objects. -Applicable since unit version 2.10.340."
          ]
        ],
        [
          "201405290137Z",
          [
            "DESCRIPTION",
            "-v1.37 -Added various missing objects (OMX-751). -Added CPE objects (OMX-162). -Applicable since unit version 2.10.320."
          ]
        ],
        [
          "201404110136Z",
          [
            "DESCRIPTION",
            "-v1.36 -Clarified relay and power output function and documentation (OMX-926). -Applicable since unit version 2.10.300."
          ]
        ],
        [
          "201401170135Z",
          [
            "DESCRIPTION",
            "-v1.35 -Added IPv6 objects (OMX-705). -Added power distribution objects (powerDistributionStatus branch) (OMX-708). -Fixed ipRestrictionMask wrong type (OMX-743). -Added ftpPushPermissions (OMX-737). -Added snmpProxy objects (OMX-747). -Applicable since unit version 2.10.150."
          ]
        ],
        [
          "201312040134Z",
          [
            "DESCRIPTION",
            "-v1.34 -Added fsGenEnable (OMX-661). -Applicable since unit version 2.10.110."
          ]
        ],
        [
          "201309040133Z",
          [
            "DESCRIPTION",
            "-v1.33 -Added pdSystemCurrent and pdSystemPower objects (OMX-527). -Added pdnDeviceCurrentValue and pdnDeviceCurrentValueStr objects (OMX-528). -Applicable since unit version 2.09.626."
          ]
        ],
        [
          "201308010132Z",
          [
            "DESCRIPTION",
            "-v1.32 -Added missing trapEventTypeNumber available values in description (OMX-437). -Applicable since unit version 2.09.560."
          ]
        ],
        [
          "201307170131Z",
          [
            "DESCRIPTION",
            "-v1.31 -Corrected snmpPBufferAllPeriod object. -Applicable since unit version 2.09.560."
          ]
        ],
        [
          "201307020130Z",
          [
            "DESCRIPTION",
            "-v1.30 -Added snmpPoll objects (OMX-394). -Applicable since unit version 2.09.560."
          ]
        ],
        [
          "201306280129Z",
          [
            "DESCRIPTION",
            "-v1.29 -Removed Ethernet Expansion card objects. -Applicable since unit version 2.09.540."
          ]
        ],
        [
          "201306130128Z",
          [
            "DESCRIPTION",
            "-v1.28 -Added sysFileTransfer and sysUpdate objects. (OMX-42) -Applicable since unit version 2.09.520."
          ]
        ],
        [
          "201306120127Z",
          [
            "DESCRIPTION",
            "-v1.27 -Renamed EX10 to Ethernet Expansion (OMX-364) -Applicable since unit version 2.09.510."
          ]
        ],
        [
          "201305280126Z",
          [
            "DESCRIPTION",
            "-v1.26 -Fixed incorrect SYNTAX for sysCharMask (OMX-328). -Applicable since unit version 2.09.380."
          ]
        ],
        [
          "201305100125Z",
          [
            "DESCRIPTION",
            "-v1.25 -Fixed incorrect SYNTAX statements for various objects (OMX-314). -Applicable since unit version 2.09.380."
          ]
        ],
        [
          "201303150124Z",
          [
            "DESCRIPTION",
            "-v1.24 -Renamed sysLocation branch to sysLoc (OMX-198). -Applicable since unit version 2.09.240."
          ]
        ],
        [
          "201302060123Z",
          [
            "DESCRIPTION",
            "-v1.23 -Added ex10 branch. -Renamed telnet* objects. -Applicable since unit version 2.09.240."
          ]
        ],
        [
          "201301140122Z",
          [
            "DESCRIPTION",
            "-v1.22 -Added evReset branch and associated notification (OMX-83). -Applicable since unit version 2.09.220."
          ]
        ],
        [
          "201211260121Z",
          [
            "DESCRIPTION",
            "-v1.21 -Fixed backwards pppRoutingEnable/ethRoutingEnable comments. (BN 4620)"
          ]
        ],
        [
          "201208220120Z",
          [
            "DESCRIPTION",
            "-v1.20 -Added additional AC power monitor items."
          ]
        ],
        [
          "201207090119Z",
          [
            "DESCRIPTION",
            "-v1.19 -Removed wirelessBand object. -Removed secSSH objects."
          ]
        ],
        [
          "201206120118Z",
          [
            "DESCRIPTION",
            "-v1.18 -Removed user credentials objects. -Added combined power distributor status objects."
          ]
        ],
        [
          "201204090117Z",
          [
            "DESCRIPTION",
            "-v1.17 -Added eth2WanRoutingEnable object."
          ]
        ],
        [
          "201204050116Z",
          [
            "DESCRIPTION",
            "-v1.16 -Added combined eventsensor status objects."
          ]
        ],
        [
          "201203060115Z",
          [
            "DESCRIPTION",
            "-v1.15 -Added objects and trap definitions for fuel sensor and AC power monitor."
          ]
        ],
        [
          "201112050900Z",
          [
            "DESCRIPTION",
            "-v1.14 -Added s571StockScriptTrap notification definition."
          ]
        ],
        [
          "201110240900Z",
          [
            "DESCRIPTION",
            "-v1.13 -Added s571StockLoadSheddingTrap notification definition."
          ]
        ],
        [
          "201108080900Z",
          [
            "DESCRIPTION",
            "-v1.12 -Added s571StockOutputTrap notification definition."
          ]
        ],
        [
          "201108010900Z",
          [
            "DESCRIPTION",
            "-v1.11 -Added evMgmtReprocess object."
          ]
        ],
        [
          "201107200900Z",
          [
            "DESCRIPTION",
            "-v1.10 -Added aisgStatus branch."
          ]
        ],
        [
          "201107080900Z",
          [
            "DESCRIPTION",
            "-v1.09 -Added wirelessModemStatus branch."
          ]
        ],
        [
          "201101050900Z",
          [
            "DESCRIPTION",
            "-v1.08 -Added espcCCNormalThreshold object."
          ]
        ],
        [
          "201012010900Z",
          [
            "DESCRIPTION",
            "-v1.07 -Added support for PowerBoss external power distributors. This is in the pdNextGen object branch which also supports the internal power distributor of the SiteBoss 571. The old SNMP support for the internal power distributor is kept in the older sub-branches of the powerDistributionStatus branch (pdConfig, pdMain, pdOutput). The idea behind the pdNextGen object branch is that there are 31 items for power monitoring and alarming, and these items are organized in a double-indexed SNMP table object: the first index is for the power distributor (and has the same numbering scheme as an EventSensor -- like esIndexES, but is called pdnIndexPD), and the second index is the power output to which the item applies (or just '1' if the item is not specific to a particular power output). E.g., to read the main current of the internal power distributor, you can use the old object (pdMainCurrentValue.0) or you can use the new object (pdnMainCurrentValue.200.1). To read the fuse event state of power output number 8 on the power distributor (PowerBoss) at index 2, read pdnOutputFuseInEventState.2.8."
          ]
        ],
        [
          "201011030900Z",
          [
            "DESCRIPTION",
            "-v1.06 -Changed deadband, threshold, and current values for temperature sensors from integer to floating-point type. This means the SNMP object type for the temperature settings (deadbands and thresholds) changed from Integer32 to DisplayString. -Fixed bug where SNMP integer range defined in the MIB for trapIncludedValue was 16-bit instead of 32-bit."
          ]
        ],
        [
          "201008240900Z",
          [
            "DESCRIPTION",
            "-v1.05 -Fixed bug where some stock traps had too few varbinds declared. -Removed useless trap definitions."
          ]
        ],
        [
          "201003170900Z",
          [
            "DESCRIPTION",
            "-v1.04 -Removed useless object consoleInlineHsk. -Added asset management object branch. -Added altitude location object. -Removed all obsolete switch references, made everything consistent on outputs (relay outputs or power outputs). -Added threshold objects for power distribution sensors. -Added pdOutputCurrentValue object. -Fixed description for pdOutputCurrentInEventState."
          ]
        ],
        [
          "201001190900Z",
          [
            "DESCRIPTION",
            "-v1.03 -Increased range for esPointValueInt"
          ]
        ],
        [
          "200910080900Z",
          [
            "DESCRIPTION",
            "-v1.02 -Incremental pre-release changes"
          ]
        ],
        [
          "200910050900Z",
          [
            "DESCRIPTION",
            "-v1.01 -Incremental pre-release changes"
          ]
        ],
        [
          "200909170900Z",
          [
            "DESCRIPTION",
            "-v1.00 -Initial version."
          ]
        ]
      ]
    ]
  ]
}
s571 · unspecifiedMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: unspecified.

Names: s571

Technical details
{
  "smi_kind": "MODULE-IDENTITY",
  "definition": [
    "s571",
    "MODULE-IDENTITY",
    "LAST-UPDATED",
    [
      "literal",
      "223230313431323330303134345a22"
    ],
    "ORGANIZATION",
    "\"Asentria Corporation\"",
    "CONTACT-INFO",
    "\"Phone: 206-344-8800 Fax: 206-344-2116 Email: support@asentria.com\"",
    "DESCRIPTION",
    "\"MIB module for managing Asentria SiteBoss 571\"",
    "REVISION",
    [
      "literal",
      "223230313431323330303134345a22"
    ],
    "DESCRIPTION",
    "\"-v1.44 -Removed wirelessPIN and scSecret objects (OMX-1064). -Applicable since unit version 2.10.610.\"",
    "REVISION",
    [
      "literal",
      "223230313431323131303134335a22"
    ],
    "DESCRIPTION",
    "\"-v1.43 -Changed analog-input fuel sensor objects from Integer32 to DisplayString (OMX-1177). -Added missing ipv6DefaultRouter object (OMX-1175). -Applicable since unit version 2.10.580.\"",
    "REVISION",
    [
      "literal",
      "223230313431303136303134325a22"
    ],
    "DESCRIPTION",
    "\"-v1.42 -Added espcAIDisplayFormat object (OMX-1112). -Removed espcAIPolarity, espcAIConvHighSign, espcAIConvLowSign objects (OMX-1113). -Applicable since unit version 2.10.460.\"",
    "REVISION",
    [
      "literal",
      "223230313431303033303134315a22"
    ],
    "DESCRIPTION",
    "\"-v1.41 -Changed analog input objects from Integer32 to DisplayString. -Applicable since unit version 2.10.460.\"",
    "REVISION",
    [
      "literal",
      "223230313430383134303134305a22"
    ],
    "DESCRIPTION",
    "\"-v1.40 -Fixed description for wirelessConnIP objects (OMX-1061). -Applicable since unit version 2.10.390.\"",
    "REVISION",
    [
      "literal",
      "223230313430373033303133395a22"
    ],
    "DESCRIPTION",
    "\"-v1.39 -Fixed wirelessIdleTimeout (OMX-1037). -Fixed CPE status objects (OMX-1036). -Applicable since unit version 2.10.390.\"",
    "REVISION",
    [
      "literal",
      "223230313430363234303133385a22"
    ],
    "DESCRIPTION",
    "\"-v1.38 -Fixed CPE status objects. -Applicable since unit version 2.10.340.\"",
    "REVISION",
    [
      "literal",
      "223230313430353239303133375a22"
    ],
    "DESCRIPTION",
    "\"-v1.37 -Added various missing objects (OMX-751). -Added CPE objects (OMX-162). -Applicable since unit version 2.10.320.\"",
    "REVISION",
    [
      "literal",
      "223230313430343131303133365a22"
    ],
    "DESCRIPTION",
    "\"-v1.36 -Clarified relay and power output function and documentation (OMX-926). -Applicable since unit version 2.10.300.\"",
    "REVISION",
    [
      "literal",
      "223230313430313137303133355a22"
    ],
    "DESCRIPTION",
    "\"-v1.35 -Added IPv6 objects (OMX-705). -Added power distribution objects (powerDistributionStatus branch) (OMX-708). -Fixed ipRestrictionMask wrong type (OMX-743). -Added ftpPushPermissions (OMX-737). -Added snmpProxy objects (OMX-747). -Applicable since unit version 2.10.150.\"",
    "REVISION",
    [
      "literal",
      "223230313331323034303133345a22"
    ],
    "DESCRIPTION",
    "\"-v1.34 -Added fsGenEnable (OMX-661). -Applicable since unit version 2.10.110.\"",
    "REVISION",
    [
      "literal",
      "223230313330393034303133335a22"
    ],
    "DESCRIPTION",
    "\"-v1.33 -Added pdSystemCurrent and pdSystemPower objects (OMX-527). -Added pdnDeviceCurrentValue and pdnDeviceCurrentValueStr objects (OMX-528). -Applicable since unit version 2.09.626.\"",
    "REVISION",
    [
      "literal",
      "223230313330383031303133325a22"
    ],
    "DESCRIPTION",
    "\"-v1.32 -Added missing trapEventTypeNumber available values in description (OMX-437). -Applicable since unit version 2.09.560.\"",
    "REVISION",
    [
      "literal",
      "223230313330373137303133315a22"
    ],
    "DESCRIPTION",
    "\"-v1.31 -Corrected snmpPBufferAllPeriod object. -Applicable since unit version 2.09.560.\"",
    "REVISION",
    [
      "literal",
      "223230313330373032303133305a22"
    ],
    "DESCRIPTION",
    "\"-v1.30 -Added snmpPoll objects (OMX-394). -Applicable since unit version 2.09.560.\"",
    "REVISION",
    [
      "literal",
      "223230313330363238303132395a22"
    ],
    "DESCRIPTION",
    "\"-v1.29 -Removed Ethernet Expansion card objects. -Applicable since unit version 2.09.540.\"",
    "REVISION",
    [
      "literal",
      "223230313330363133303132385a22"
    ],
    "DESCRIPTION",
    "\"-v1.28 -Added sysFileTransfer and sysUpdate objects. (OMX-42) -Applicable since unit version 2.09.520.\"",
    "REVISION",
    [
      "literal",
      "223230313330363132303132375a22"
    ],
    "DESCRIPTION",
    "\"-v1.27 -Renamed EX10 to Ethernet Expansion (OMX-364) -Applicable since unit version 2.09.510.\"",
    "REVISION",
    [
      "literal",
      "223230313330353238303132365a22"
    ],
    "DESCRIPTION",
    "\"-v1.26 -Fixed incorrect SYNTAX for sysCharMask (OMX-328). -Applicable since unit version 2.09.380.\"",
    "REVISION",
    [
      "literal",
      "223230313330353130303132355a22"
    ],
    "DESCRIPTION",
    "\"-v1.25 -Fixed incorrect SYNTAX statements for various objects (OMX-314). -Applicable since unit version 2.09.380.\"",
    "REVISION",
    [
      "literal",
      "223230313330333135303132345a22"
    ],
    "DESCRIPTION",
    "\"-v1.24 -Renamed sysLocation branch to sysLoc (OMX-198). -Applicable since unit version 2.09.240.\"",
    "REVISION",
    [
      "literal",
      "223230313330323036303132335a22"
    ],
    "DESCRIPTION",
    "\"-v1.23 -Added ex10 branch. -Renamed telnet* objects. -Applicable since unit version 2.09.240.\"",
    "REVISION",
    [
      "literal",
      "223230313330313134303132325a22"
    ],
    "DESCRIPTION",
    "\"-v1.22 -Added evReset branch and associated notification (OMX-83). -Applicable since unit version 2.09.220.\"",
    "REVISION",
    [
      "literal",
      "223230313231313236303132315a22"
    ],
    "DESCRIPTION",
    "\"-v1.21 -Fixed backwards pppRoutingEnable/ethRoutingEnable comments. (BN 4620)\"",
    "REVISION",
    [
      "literal",
      "223230313230383232303132305a22"
    ],
    "DESCRIPTION",
    "\"-v1.20 -Added additional AC power monitor items.\"",
    "REVISION",
    [
      "literal",
      "223230313230373039303131395a22"
    ],
    "DESCRIPTION",
    "\"-v1.19 -Removed wirelessBand object. -Removed secSSH objects.\"",
    "REVISION",
    [
      "literal",
      "223230313230363132303131385a22"
    ],
    "DESCRIPTION",
    "\"-v1.18 -Removed user credentials objects. -Added combined power distributor status objects.\"",
    "REVISION",
    [
      "literal",
      "223230313230343039303131375a22"
    ],
    "DESCRIPTION",
    "\"-v1.17 -Added eth2WanRoutingEnable object.\"",
    "REVISION",
    [
      "literal",
      "223230313230343035303131365a22"
    ],
    "DESCRIPTION",
    "\"-v1.16 -Added combined eventsensor status objects.\"",
    "REVISION",
    [
      "literal",
      "223230313230333036303131355a22"
    ],
    "DESCRIPTION",
    "\"-v1.15 -Added objects and trap definitions for fuel sensor and AC power monitor.\"",
    "REVISION",
    [
      "literal",
      "223230313131323035303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.14 -Added s571StockScriptTrap notification definition.\"",
    "REVISION",
    [
      "literal",
      "223230313131303234303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.13 -Added s571StockLoadSheddingTrap notification definition.\"",
    "REVISION",
    [
      "literal",
      "223230313130383038303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.12 -Added s571StockOutputTrap notification definition.\"",
    "REVISION",
    [
      "literal",
      "223230313130383031303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.11 -Added evMgmtReprocess object.\"",
    "REVISION",
    [
      "literal",
      "223230313130373230303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.10 -Added aisgStatus branch.\"",
    "REVISION",
    [
      "literal",
      "223230313130373038303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.09 -Added wirelessModemStatus branch.\"",
    "REVISION",
    [
      "literal",
      "223230313130313035303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.08 -Added espcCCNormalThreshold object.\"",
    "REVISION",
    [
      "literal",
      "223230313031323031303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.07 -Added support for PowerBoss external power distributors. This is in the pdNextGen object branch which also supports the internal power distributor of the SiteBoss 571. The old SNMP support for the internal power distributor is kept in the older sub-branches of the powerDistributionStatus branch (pdConfig, pdMain, pdOutput). The idea behind the pdNextGen object branch is that there are 31 items for power monitoring and alarming, and these items are organized in a double-indexed SNMP table object: the first index is for the power distributor (and has the same numbering scheme as an EventSensor -- like esIndexES, but is called pdnIndexPD), and the second index is the power output to which the item applies (or just '1' if the item is not specific to a particular power output). E.g., to read the main current of the internal power distributor, you can use the old object (pdMainCurrentValue.0) or you can use the new object (pdnMainCurrentValue.200.1). To read the fuse event state of power output number 8 on the power distributor (PowerBoss) at index 2, read pdnOutputFuseInEventState.2.8.\"",
    "REVISION",
    [
      "literal",
      "223230313031313033303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.06 -Changed deadband, threshold, and current values for temperature sensors from integer to floating-point type. This means the SNMP object type for the temperature settings (deadbands and thresholds) changed from Integer32 to DisplayString. -Fixed bug where SNMP integer range defined in the MIB for trapIncludedValue was 16-bit instead of 32-bit.\"",
    "REVISION",
    [
      "literal",
      "223230313030383234303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.05 -Fixed bug where some stock traps had too few varbinds declared. -Removed useless trap definitions.\"",
    "REVISION",
    [
      "literal",
      "223230313030333137303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.04 -Removed useless object consoleInlineHsk. -Added asset management object branch. -Added altitude location object. -Removed all obsolete switch references, made everything consistent on outputs (relay outputs or power outputs). -Added threshold objects for power distribution sensors. -Added pdOutputCurrentValue object. -Fixed description for pdOutputCurrentInEventState.\"",
    "REVISION",
    [
      "literal",
      "223230313030313139303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.03 -Increased range for esPointValueInt\"",
    "REVISION",
    [
      "literal",
      "223230303931303038303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.02 -Incremental pre-release changes\"",
    "REVISION",
    [
      "literal",
      "223230303931303035303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.01 -Incremental pre-release changes\"",
    "REVISION",
    [
      "literal",
      "223230303930393137303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.00 -Initial version.\"",
    "::=",
    "{",
    "asentria",
    "14",
    "}"
  ],
  "syntax_tree": [
    [
      "LAST-UPDATED",
      "201412300144Z"
    ],
    [
      "ORGANIZATION",
      "Asentria Corporation"
    ],
    [
      "CONTACT-INFO",
      "Phone: 206-344-8800 Fax: 206-344-2116 Email: support@asentria.com"
    ],
    [
      "DESCRIPTION",
      "MIB module for managing Asentria SiteBoss 571"
    ],
    [
      "Revisions",
      [
        [
          "201412300144Z",
          [
            "DESCRIPTION",
            "-v1.44 -Removed wirelessPIN and scSecret objects (OMX-1064). -Applicable since unit version 2.10.610."
          ]
        ],
        [
          "201412110143Z",
          [
            "DESCRIPTION",
            "-v1.43 -Changed analog-input fuel sensor objects from Integer32 to DisplayString (OMX-1177). -Added missing ipv6DefaultRouter object (OMX-1175). -Applicable since unit version 2.10.580."
          ]
        ],
        [
          "201410160142Z",
          [
            "DESCRIPTION",
            "-v1.42 -Added espcAIDisplayFormat object (OMX-1112). -Removed espcAIPolarity, espcAIConvHighSign, espcAIConvLowSign objects (OMX-1113). -Applicable since unit version 2.10.460."
          ]
        ],
        [
          "201410030141Z",
          [
            "DESCRIPTION",
            "-v1.41 -Changed analog input objects from Integer32 to DisplayString. -Applicable since unit version 2.10.460."
          ]
        ],
        [
          "201408140140Z",
          [
            "DESCRIPTION",
            "-v1.40 -Fixed description for wirelessConnIP objects (OMX-1061). -Applicable since unit version 2.10.390."
          ]
        ],
        [
          "201407030139Z",
          [
            "DESCRIPTION",
            "-v1.39 -Fixed wirelessIdleTimeout (OMX-1037). -Fixed CPE status objects (OMX-1036). -Applicable since unit version 2.10.390."
          ]
        ],
        [
          "201406240138Z",
          [
            "DESCRIPTION",
            "-v1.38 -Fixed CPE status objects. -Applicable since unit version 2.10.340."
          ]
        ],
        [
          "201405290137Z",
          [
            "DESCRIPTION",
            "-v1.37 -Added various missing objects (OMX-751). -Added CPE objects (OMX-162). -Applicable since unit version 2.10.320."
          ]
        ],
        [
          "201404110136Z",
          [
            "DESCRIPTION",
            "-v1.36 -Clarified relay and power output function and documentation (OMX-926). -Applicable since unit version 2.10.300."
          ]
        ],
        [
          "201401170135Z",
          [
            "DESCRIPTION",
            "-v1.35 -Added IPv6 objects (OMX-705). -Added power distribution objects (powerDistributionStatus branch) (OMX-708). -Fixed ipRestrictionMask wrong type (OMX-743). -Added ftpPushPermissions (OMX-737). -Added snmpProxy objects (OMX-747). -Applicable since unit version 2.10.150."
          ]
        ],
        [
          "201312040134Z",
          [
            "DESCRIPTION",
            "-v1.34 -Added fsGenEnable (OMX-661). -Applicable since unit version 2.10.110."
          ]
        ],
        [
          "201309040133Z",
          [
            "DESCRIPTION",
            "-v1.33 -Added pdSystemCurrent and pdSystemPower objects (OMX-527). -Added pdnDeviceCurrentValue and pdnDeviceCurrentValueStr objects (OMX-528). -Applicable since unit version 2.09.626."
          ]
        ],
        [
          "201308010132Z",
          [
            "DESCRIPTION",
            "-v1.32 -Added missing trapEventTypeNumber available values in description (OMX-437). -Applicable since unit version 2.09.560."
          ]
        ],
        [
          "201307170131Z",
          [
            "DESCRIPTION",
            "-v1.31 -Corrected snmpPBufferAllPeriod object. -Applicable since unit version 2.09.560."
          ]
        ],
        [
          "201307020130Z",
          [
            "DESCRIPTION",
            "-v1.30 -Added snmpPoll objects (OMX-394). -Applicable since unit version 2.09.560."
          ]
        ],
        [
          "201306280129Z",
          [
            "DESCRIPTION",
            "-v1.29 -Removed Ethernet Expansion card objects. -Applicable since unit version 2.09.540."
          ]
        ],
        [
          "201306130128Z",
          [
            "DESCRIPTION",
            "-v1.28 -Added sysFileTransfer and sysUpdate objects. (OMX-42) -Applicable since unit version 2.09.520."
          ]
        ],
        [
          "201306120127Z",
          [
            "DESCRIPTION",
            "-v1.27 -Renamed EX10 to Ethernet Expansion (OMX-364) -Applicable since unit version 2.09.510."
          ]
        ],
        [
          "201305280126Z",
          [
            "DESCRIPTION",
            "-v1.26 -Fixed incorrect SYNTAX for sysCharMask (OMX-328). -Applicable since unit version 2.09.380."
          ]
        ],
        [
          "201305100125Z",
          [
            "DESCRIPTION",
            "-v1.25 -Fixed incorrect SYNTAX statements for various objects (OMX-314). -Applicable since unit version 2.09.380."
          ]
        ],
        [
          "201303150124Z",
          [
            "DESCRIPTION",
            "-v1.24 -Renamed sysLocation branch to sysLoc (OMX-198). -Applicable since unit version 2.09.240."
          ]
        ],
        [
          "201302060123Z",
          [
            "DESCRIPTION",
            "-v1.23 -Added ex10 branch. -Renamed telnet* objects. -Applicable since unit version 2.09.240."
          ]
        ],
        [
          "201301140122Z",
          [
            "DESCRIPTION",
            "-v1.22 -Added evReset branch and associated notification (OMX-83). -Applicable since unit version 2.09.220."
          ]
        ],
        [
          "201211260121Z",
          [
            "DESCRIPTION",
            "-v1.21 -Fixed backwards pppRoutingEnable/ethRoutingEnable comments. (BN 4620)"
          ]
        ],
        [
          "201208220120Z",
          [
            "DESCRIPTION",
            "-v1.20 -Added additional AC power monitor items."
          ]
        ],
        [
          "201207090119Z",
          [
            "DESCRIPTION",
            "-v1.19 -Removed wirelessBand object. -Removed secSSH objects."
          ]
        ],
        [
          "201206120118Z",
          [
            "DESCRIPTION",
            "-v1.18 -Removed user credentials objects. -Added combined power distributor status objects."
          ]
        ],
        [
          "201204090117Z",
          [
            "DESCRIPTION",
            "-v1.17 -Added eth2WanRoutingEnable object."
          ]
        ],
        [
          "201204050116Z",
          [
            "DESCRIPTION",
            "-v1.16 -Added combined eventsensor status objects."
          ]
        ],
        [
          "201203060115Z",
          [
            "DESCRIPTION",
            "-v1.15 -Added objects and trap definitions for fuel sensor and AC power monitor."
          ]
        ],
        [
          "201112050900Z",
          [
            "DESCRIPTION",
            "-v1.14 -Added s571StockScriptTrap notification definition."
          ]
        ],
        [
          "201110240900Z",
          [
            "DESCRIPTION",
            "-v1.13 -Added s571StockLoadSheddingTrap notification definition."
          ]
        ],
        [
          "201108080900Z",
          [
            "DESCRIPTION",
            "-v1.12 -Added s571StockOutputTrap notification definition."
          ]
        ],
        [
          "201108010900Z",
          [
            "DESCRIPTION",
            "-v1.11 -Added evMgmtReprocess object."
          ]
        ],
        [
          "201107200900Z",
          [
            "DESCRIPTION",
            "-v1.10 -Added aisgStatus branch."
          ]
        ],
        [
          "201107080900Z",
          [
            "DESCRIPTION",
            "-v1.09 -Added wirelessModemStatus branch."
          ]
        ],
        [
          "201101050900Z",
          [
            "DESCRIPTION",
            "-v1.08 -Added espcCCNormalThreshold object."
          ]
        ],
        [
          "201012010900Z",
          [
            "DESCRIPTION",
            "-v1.07 -Added support for PowerBoss external power distributors. This is in the pdNextGen object branch which also supports the internal power distributor of the SiteBoss 571. The old SNMP support for the internal power distributor is kept in the older sub-branches of the powerDistributionStatus branch (pdConfig, pdMain, pdOutput). The idea behind the pdNextGen object branch is that there are 31 items for power monitoring and alarming, and these items are organized in a double-indexed SNMP table object: the first index is for the power distributor (and has the same numbering scheme as an EventSensor -- like esIndexES, but is called pdnIndexPD), and the second index is the power output to which the item applies (or just '1' if the item is not specific to a particular power output). E.g., to read the main current of the internal power distributor, you can use the old object (pdMainCurrentValue.0) or you can use the new object (pdnMainCurrentValue.200.1). To read the fuse event state of power output number 8 on the power distributor (PowerBoss) at index 2, read pdnOutputFuseInEventState.2.8."
          ]
        ],
        [
          "201011030900Z",
          [
            "DESCRIPTION",
            "-v1.06 -Changed deadband, threshold, and current values for temperature sensors from integer to floating-point type. This means the SNMP object type for the temperature settings (deadbands and thresholds) changed from Integer32 to DisplayString. -Fixed bug where SNMP integer range defined in the MIB for trapIncludedValue was 16-bit instead of 32-bit."
          ]
        ],
        [
          "201008240900Z",
          [
            "DESCRIPTION",
            "-v1.05 -Fixed bug where some stock traps had too few varbinds declared. -Removed useless trap definitions."
          ]
        ],
        [
          "201003170900Z",
          [
            "DESCRIPTION",
            "-v1.04 -Removed useless object consoleInlineHsk. -Added asset management object branch. -Added altitude location object. -Removed all obsolete switch references, made everything consistent on outputs (relay outputs or power outputs). -Added threshold objects for power distribution sensors. -Added pdOutputCurrentValue object. -Fixed description for pdOutputCurrentInEventState."
          ]
        ],
        [
          "201001190900Z",
          [
            "DESCRIPTION",
            "-v1.03 -Increased range for esPointValueInt"
          ]
        ],
        [
          "200910080900Z",
          [
            "DESCRIPTION",
            "-v1.02 -Incremental pre-release changes"
          ]
        ],
        [
          "200910050900Z",
          [
            "DESCRIPTION",
            "-v1.01 -Incremental pre-release changes"
          ]
        ],
        [
          "200909170900Z",
          [
            "DESCRIPTION",
            "-v1.00 -Initial version."
          ]
        ]
      ]
    ]
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.3052)

Renton Paul

Direct children (231)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.3052.14.1019 s571UserTrap101900
1.3.6.1.4.1.3052.14.1020 s571UserTrap102000
1.3.6.1.4.1.3052.14.1021 s571UserTrap102100
1.3.6.1.4.1.3052.14.1022 s571UserTrap102200
1.3.6.1.4.1.3052.14.1023 s571UserTrap102300
1.3.6.1.4.1.3052.14.1024 s571UserTrap102400
1.3.6.1.4.1.3052.14.1025 s571UserTrap102500
1.3.6.1.4.1.3052.14.1026 s571UserTrap102600
1.3.6.1.4.1.3052.14.1027 s571UserTrap102700
1.3.6.1.4.1.3052.14.1028 s571UserTrap102800
1.3.6.1.4.1.3052.14.1029 s571UserTrap102900
1.3.6.1.4.1.3052.14.1030 s571UserTrap103000
1.3.6.1.4.1.3052.14.1031 s571UserTrap103100
1.3.6.1.4.1.3052.14.1032 s571UserTrap103200
1.3.6.1.4.1.3052.14.1033 s571UserTrap103300
1.3.6.1.4.1.3052.14.1034 s571UserTrap103400
1.3.6.1.4.1.3052.14.1035 s571UserTrap103500
1.3.6.1.4.1.3052.14.1036 s571UserTrap103600
1.3.6.1.4.1.3052.14.1037 s571UserTrap103700
1.3.6.1.4.1.3052.14.1038 s571UserTrap103800
1.3.6.1.4.1.3052.14.1039 s571UserTrap103900
1.3.6.1.4.1.3052.14.1040 s571UserTrap104000
1.3.6.1.4.1.3052.14.1041 s571UserTrap104100
1.3.6.1.4.1.3052.14.1042 s571UserTrap104200
1.3.6.1.4.1.3052.14.1043 s571UserTrap104300
1.3.6.1.4.1.3052.14.1044 s571UserTrap104400
1.3.6.1.4.1.3052.14.1045 s571UserTrap104500
1.3.6.1.4.1.3052.14.1046 s571UserTrap104600
1.3.6.1.4.1.3052.14.1047 s571UserTrap104700
1.3.6.1.4.1.3052.14.1048 s571UserTrap104800
1.3.6.1.4.1.3052.14.1049 s571UserTrap104900
1.3.6.1.4.1.3052.14.1050 s571UserTrap105000
1.3.6.1.4.1.3052.14.1051 s571UserTrap105100
1.3.6.1.4.1.3052.14.1052 s571UserTrap105200
1.3.6.1.4.1.3052.14.1053 s571UserTrap105300
1.3.6.1.4.1.3052.14.1054 s571UserTrap105400
1.3.6.1.4.1.3052.14.1055 s571UserTrap105500
1.3.6.1.4.1.3052.14.1056 s571UserTrap105600
1.3.6.1.4.1.3052.14.1057 s571UserTrap105700
1.3.6.1.4.1.3052.14.1058 s571UserTrap105800
1.3.6.1.4.1.3052.14.1059 s571UserTrap105900
1.3.6.1.4.1.3052.14.1060 s571UserTrap106000
1.3.6.1.4.1.3052.14.1061 s571UserTrap106100
1.3.6.1.4.1.3052.14.1062 s571UserTrap106200
1.3.6.1.4.1.3052.14.1063 s571UserTrap106300
1.3.6.1.4.1.3052.14.1064 s571UserTrap106400
1.3.6.1.4.1.3052.14.1065 s571UserTrap106500
1.3.6.1.4.1.3052.14.1066 s571UserTrap106600
1.3.6.1.4.1.3052.14.1067 s571UserTrap106700
1.3.6.1.4.1.3052.14.1068 s571UserTrap106800

Siblings (25)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.3052.1 datalink19379
1.3.6.1.4.1.3052.3 dl209419
1.3.6.1.4.1.3052.4 sl61211565
1.3.6.1.4.1.3052.5 sl81213571
1.3.6.1.4.1.3052.6 dl150215451
1.3.6.1.4.1.3052.7 dl80215451
1.3.6.1.4.1.3052.8 s5702261390
1.3.6.1.4.1.3052.10 s55052205
1.3.6.1.4.1.3052.12 s5302281302
1.3.6.1.4.1.3052.17 s45051489
1.3.6.1.4.1.3052.18 s35051652
1.3.6.1.4.1.3052.20 s57251499
1.3.6.1.4.1.3052.23 s36052239
1.3.6.1.4.1.3052.40 s410, sl1069343 S410
1.3.6.1.4.1.3052.41 s412, sl1263296
1.3.6.1.4.1.3052.42 s4208133
1.3.6.1.4.1.3052.43 s2208133
1.3.6.1.4.1.3052.501 datalinkDbasePfullTrap00
1.3.6.1.4.1.3052.502 datalinkFilePfullTrap00
1.3.6.1.4.1.3052.503 datalinkDataAlarmTrap00
1.3.6.1.4.1.3052.504 datalinkSensorAlarmTrap00
1.3.6.1.4.1.3052.505 datalinkNoDataAlarmTrap00
1.3.6.1.4.1.3052.506 datalinkSchedTrap00
1.3.6.1.4.1.3052.507 datalinkImmediateTrap00
1.3.6.1.4.1.3052.509 datalinkPPPupTrap00