OID reference

s571

1.3.6.1.4.1.3052.14

Description

MIB module for managing Asentria SiteBoss 571

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.3052 (asentria, omnitronix)
Node code
14
Node name
s571
Numeric OID
1.3.6.1.4.1.3052.14
URN notation
urn:oid:1.3.6.1.4.1.3052.14
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 3052 14}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) asentria(3052) s571(14)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) omnitronix(3052) s571(14)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) asentria(3052) s571(14)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) omnitronix(3052) s571(14)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) asentria(3052) s571(14)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) omnitronix(3052) s571(14)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) asentria(3052) s571(14)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) omnitronix(3052) s571(14)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) asentria(3052) s571(14)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) omnitronix(3052) s571(14)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) asentria(3052) s571(14)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) omnitronix(3052) s571(14)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) asentria(3052) s571(14)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) omnitronix(3052) s571(14)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) asentria(3052) s571(14)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) omnitronix(3052) s571(14)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/3052/14
  • /ISO/Identified-Organization/6/1/4/1/3052/14
  • /ISO/3/6/1/4/1/3052/14
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/asentria/s571
  • /iso/identified-organization/dod/internet/private/enterprise/omnitronix/s571
  • /iso/identified-organization/dod/internet/private/enterprises/asentria/s571
  • /iso/identified-organization/dod/internet/private/enterprises/omnitronix/s571
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/asentria/s571
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/omnitronix/s571
  • /iso/identified-organization/dod/internet/private/vendor-objects/asentria/s571
  • /iso/identified-organization/dod/internet/private/vendor-objects/omnitronix/s571
  • /iso/org/dod/internet/private/enterprise/asentria/s571
  • /iso/org/dod/internet/private/enterprise/omnitronix/s571
  • /iso/org/dod/internet/private/enterprises/asentria/s571
  • /iso/org/dod/internet/private/enterprises/omnitronix/s571
  • /iso/org/dod/internet/private/ldap-enterprise/asentria/s571
  • /iso/org/dod/internet/private/ldap-enterprise/omnitronix/s571
  • /iso/org/dod/internet/private/vendor-objects/asentria/s571
  • /iso/org/dod/internet/private/vendor-objects/omnitronix/s571
  • Additional combinations skipped.

Available source records contain 2 distinct definitions; some records may not include a definition.

Show 2 published definitions

s571 · unspecified

s571 MODULE-IDENTITY
    LAST-UPDATED "201412110143Z"
    ORGANIZATION "Asentria Corporation"
    CONTACT-INFO
     "Phone:  206-344-8800
      Fax:    206-344-2116
      Email:  support@asentria.com"
    DESCRIPTION
      "MIB module for managing Asentria SiteBoss 571"

    REVISION      "201412110143Z"
    DESCRIPTION
      "-v1.43
       -Changed analog-input fuel sensor objects from Integer32 to DisplayString (OMX-1177).
       -Added missing ipv6DefaultRouter object (OMX-1175).
       -Applicable since unit version 2.10.580."

    REVISION      "201410160142Z"
    DESCRIPTION
      "-v1.42
       -Added espcAIDisplayFormat object (OMX-1112).
       -Removed espcAIPolarity, espcAIConvHighSign, espcAIConvLowSign objects (OMX-1113).
       -Applicable since unit version 2.10.460."

    REVISION      "201410030141Z"
    DESCRIPTION
      "-v1.41
       -Changed analog input objects from Integer32 to DisplayString.
       -Applicable since unit version 2.10.460."

    REVISION      "201408140140Z"
    DESCRIPTION
      "-v1.40
       -Fixed description for wirelessConnIP objects (OMX-1061).
       -Applicable since unit version 2.10.390."

    REVISION      "201407030139Z"
    DESCRIPTION
      "-v1.39
       -Fixed wirelessIdleTimeout (OMX-1037).
       -Fixed CPE status objects (OMX-1036).
       -Applicable since unit version 2.10.390."

    REVISION      "201406240138Z"
    DESCRIPTION
      "-v1.38
       -Fixed CPE status objects.
       -Applicable since unit version 2.10.340."

    REVISION      "201405290137Z"
    DESCRIPTION
      "-v1.37
       -Added various missing objects (OMX-751).
       -Added CPE objects (OMX-162).
       -Applicable since unit version 2.10.320."

    REVISION      "201404110136Z"
    DESCRIPTION
      "-v1.36
       -Clarified relay and power output function and documentation (OMX-926).
       -Applicable since unit version 2.10.300."

    REVISION      "201401170135Z"
    DESCRIPTION
      "-v1.35
       -Added IPv6 objects (OMX-705).
       -Added power distribution objects (powerDistributionStatus branch) (OMX-708).
       -Fixed ipRestrictionMask wrong type (OMX-743).
       -Added ftpPushPermissions (OMX-737).
       -Added snmpProxy objects (OMX-747).
       -Applicable since unit version 2.10.150."

    REVISION      "201312040134Z"
    DESCRIPTION
      "-v1.34
       -Added fsGenEnable (OMX-661).
       -Applicable since unit version 2.10.110."

    REVISION      "201309040133Z"
    DESCRIPTION
      "-v1.33
       -Added pdSystemCurrent and pdSystemPower objects (OMX-527).
       -Added pdnDeviceCurrentValue and pdnDeviceCurrentValueStr objects (OMX-528).
       -Applicable since unit version 2.09.626."

    REVISION      "201308010132Z"
    DESCRIPTION
      "-v1.32
       -Added missing trapEventTypeNumber available values in description (OMX-437).
       -Applicable since unit version 2.09.560."

    REVISION      "201307170131Z"
    DESCRIPTION
      "-v1.31
       -Corrected snmpPBufferAllPeriod object.
       -Applicable since unit version 2.09.560."

    REVISION      "201307020130Z"
    DESCRIPTION
      "-v1.30
       -Added snmpPoll objects (OMX-394).
       -Applicable since unit version 2.09.560."

    REVISION      "201306280129Z"
    DESCRIPTION
      "-v1.29
       -Removed Ethernet Expansion card objects.
       -Applicable since unit version 2.09.540."

    REVISION      "201306130128Z"
    DESCRIPTION
      "-v1.28
       -Added sysFileTransfer and sysUpdate objects. (OMX-42)
       -Applicable since unit version 2.09.520."

    REVISION      "201306120127Z"
    DESCRIPTION
      "-v1.27
       -Renamed EX10 to Ethernet Expansion (OMX-364)
       -Applicable since unit version 2.09.510."

    REVISION      "201305280126Z"
    DESCRIPTION
      "-v1.26
       -Fixed incorrect SYNTAX for sysCharMask (OMX-328).
       -Applicable since unit version 2.09.380."

    REVISION      "201305100125Z"
    DESCRIPTION
      "-v1.25
       -Fixed incorrect SYNTAX statements for various objects (OMX-314).
       -Applicable since unit version 2.09.380."

    REVISION      "201303150124Z"
    DESCRIPTION
      "-v1.24
       -Renamed sysLocation branch to sysLoc (OMX-198).
       -Applicable since unit version 2.09.240."

    REVISION      "201302060123Z"
    DESCRIPTION
      "-v1.23
       -Added ex10 branch.
       -Renamed telnet* objects.
       -Applicable since unit version 2.09.240."

    REVISION      "201301140122Z"
    DESCRIPTION
      "-v1.22
       -Added evReset branch and associated notification (OMX-83).
       -Applicable since unit version 2.09.220."

    REVISION      "201211260121Z"
    DESCRIPTION
      "-v1.21
       -Fixed backwards pppRoutingEnable/ethRoutingEnable comments.  (BN 4620)"

    REVISION      "201208220120Z"
    DESCRIPTION
      "-v1.20
       -Added additional AC power monitor items."

    REVISION      "201207090119Z"
    DESCRIPTION
      "-v1.19
       -Removed wirelessBand object.
       -Removed secSSH objects."

    REVISION      "201206120118Z"
    DESCRIPTION
      "-v1.18
       -Removed user credentials objects.
       -Added combined power distributor status objects."

    REVISION      "201204090117Z"
    DESCRIPTION
      "-v1.17
       -Added eth2WanRoutingEnable object."

    REVISION      "201204050116Z"
    DESCRIPTION
      "-v1.16
       -Added combined eventsensor status objects."

    REVISION      "201203060115Z"
    DESCRIPTION
      "-v1.15
       -Added objects and trap definitions for fuel sensor and AC power monitor."

    REVISION      "201112050900Z"
    DESCRIPTION
      "-v1.14
       -Added s571StockScriptTrap notification definition."

    REVISION      "201110240900Z"
    DESCRIPTION
      "-v1.13
       -Added s571StockLoadSheddingTrap notification definition."

    REVISION      "201108080900Z"
    DESCRIPTION
      "-v1.12
       -Added s571StockOutputTrap notification definition."

    REVISION      "201108010900Z"
    DESCRIPTION
      "-v1.11
       -Added evMgmtReprocess object."

    REVISION      "201107200900Z"
    DESCRIPTION
      "-v1.10
       -Added aisgStatus branch."

    REVISION      "201107080900Z"
    DESCRIPTION
      "-v1.09
       -Added wirelessModemStatus branch."

    REVISION      "201101050900Z"
    DESCRIPTION
      "-v1.08
       -Added espcCCNormalThreshold object."

    REVISION      "201012010900Z"
    DESCRIPTION
      "-v1.07
       -Added support for PowerBoss external power distributors.  This is in the
       pdNextGen object branch which also supports the internal power distributor
       of the SiteBoss 571.  The old SNMP support for the internal power
       distributor is kept in the older sub-branches of the powerDistributionStatus
       branch (pdConfig, pdMain, pdOutput).  The idea behind the pdNextGen object
       branch is that there are 31 items for power monitoring and alarming, and
       these items are organized in a double-indexed SNMP table object: the first
       index is for the power distributor (and has the same numbering scheme as an
       EventSensor  -- like esIndexES, but is called pdnIndexPD), and the second
       index is the power output to which the item applies (or just '1' if the item
       is not specific to a particular power output).  E.g., to read the main
       current of the internal power distributor, you can use the old object
       (pdMainCurrentValue.0) or you can use the new object
       (pdnMainCurrentValue.200.1).  To read the fuse event state of power output
       number 8 on the power distributor (PowerBoss) at index 2, read
       pdnOutputFuseInEventState.2.8."

    REVISION      "201011030900Z"
    DESCRIPTION
      "-v1.06
       -Changed deadband, threshold, and current values for temperature
       sensors from integer to floating-point type.  This means the
       SNMP object type for the temperature settings (deadbands and
       thresholds) changed from Integer32 to DisplayString.
       -Fixed bug where SNMP integer range defined in the MIB for
       trapIncludedValue was 16-bit instead of 32-bit."

    REVISION      "201008240900Z"
    DESCRIPTION
      "-v1.05
       -Fixed bug where some stock traps had too few varbinds declared.
       -Removed useless trap definitions."

    REVISION      "201003170900Z"
    DESCRIPTION
      "-v1.04
       -Removed useless object consoleInlineHsk.
       -Added asset management object branch.
       -Added altitude location object.
       -Removed all obsolete switch references, made everything consistent
        on outputs (relay outputs or power outputs).
       -Added threshold objects for power distribution sensors.
       -Added pdOutputCurrentValue object.
       -Fixed description for pdOutputCurrentInEventState."

    REVISION      "201001190900Z"
    DESCRIPTION
      "-v1.03
       -Increased range for esPointValueInt"

    REVISION      "200910080900Z"
    DESCRIPTION
      "-v1.02
       -Incremental pre-release changes"

    REVISION      "200910050900Z"
    DESCRIPTION
      "-v1.01
       -Incremental pre-release changes"

    REVISION      "200909170900Z"
    DESCRIPTION
      "-v1.00
       -Initial version."

    ::= { asentria 14 }

s571 · unspecified

s571 MODULE-IDENTITY
    LAST-UPDATED "201412300144Z"
    ORGANIZATION "Asentria Corporation"
    CONTACT-INFO
     "Phone:  206-344-8800
      Fax:    206-344-2116
      Email:  support@asentria.com"
    DESCRIPTION
      "MIB module for managing Asentria SiteBoss 571"

    REVISION      "201412300144Z"
    DESCRIPTION
      "-v1.44
       -Removed wirelessPIN and scSecret objects (OMX-1064).
       -Applicable since unit version 2.10.610."

    REVISION      "201412110143Z"
    DESCRIPTION
      "-v1.43
       -Changed analog-input fuel sensor objects from Integer32 to DisplayString (OMX-1177).
       -Added missing ipv6DefaultRouter object (OMX-1175).
       -Applicable since unit version 2.10.580."

    REVISION      "201410160142Z"
    DESCRIPTION
      "-v1.42
       -Added espcAIDisplayFormat object (OMX-1112).
       -Removed espcAIPolarity, espcAIConvHighSign, espcAIConvLowSign objects (OMX-1113).
       -Applicable since unit version 2.10.460."

    REVISION      "201410030141Z"
    DESCRIPTION
      "-v1.41
       -Changed analog input objects from Integer32 to DisplayString.
       -Applicable since unit version 2.10.460."

    REVISION      "201408140140Z"
    DESCRIPTION
      "-v1.40
       -Fixed description for wirelessConnIP objects (OMX-1061).
       -Applicable since unit version 2.10.390."

    REVISION      "201407030139Z"
    DESCRIPTION
      "-v1.39
       -Fixed wirelessIdleTimeout (OMX-1037).
       -Fixed CPE status objects (OMX-1036).
       -Applicable since unit version 2.10.390."

    REVISION      "201406240138Z"
    DESCRIPTION
      "-v1.38
       -Fixed CPE status objects.
       -Applicable since unit version 2.10.340."

    REVISION      "201405290137Z"
    DESCRIPTION
      "-v1.37
       -Added various missing objects (OMX-751).
       -Added CPE objects (OMX-162).
       -Applicable since unit version 2.10.320."

    REVISION      "201404110136Z"
    DESCRIPTION
      "-v1.36
       -Clarified relay and power output function and documentation (OMX-926).
       -Applicable since unit version 2.10.300."

    REVISION      "201401170135Z"
    DESCRIPTION
      "-v1.35
       -Added IPv6 objects (OMX-705).
       -Added power distribution objects (powerDistributionStatus branch) (OMX-708).
       -Fixed ipRestrictionMask wrong type (OMX-743).
       -Added ftpPushPermissions (OMX-737).
       -Added snmpProxy objects (OMX-747).
       -Applicable since unit version 2.10.150."

    REVISION      "201312040134Z"
    DESCRIPTION
      "-v1.34
       -Added fsGenEnable (OMX-661).
       -Applicable since unit version 2.10.110."

    REVISION      "201309040133Z"
    DESCRIPTION
      "-v1.33
       -Added pdSystemCurrent and pdSystemPower objects (OMX-527).
       -Added pdnDeviceCurrentValue and pdnDeviceCurrentValueStr objects (OMX-528).
       -Applicable since unit version 2.09.626."

    REVISION      "201308010132Z"
    DESCRIPTION
      "-v1.32
       -Added missing trapEventTypeNumber available values in description (OMX-437).
       -Applicable since unit version 2.09.560."

    REVISION      "201307170131Z"
    DESCRIPTION
      "-v1.31
       -Corrected snmpPBufferAllPeriod object.
       -Applicable since unit version 2.09.560."

    REVISION      "201307020130Z"
    DESCRIPTION
      "-v1.30
       -Added snmpPoll objects (OMX-394).
       -Applicable since unit version 2.09.560."

    REVISION      "201306280129Z"
    DESCRIPTION
      "-v1.29
       -Removed Ethernet Expansion card objects.
       -Applicable since unit version 2.09.540."

    REVISION      "201306130128Z"
    DESCRIPTION
      "-v1.28
       -Added sysFileTransfer and sysUpdate objects. (OMX-42)
       -Applicable since unit version 2.09.520."

    REVISION      "201306120127Z"
    DESCRIPTION
      "-v1.27
       -Renamed EX10 to Ethernet Expansion (OMX-364)
       -Applicable since unit version 2.09.510."

    REVISION      "201305280126Z"
    DESCRIPTION
      "-v1.26
       -Fixed incorrect SYNTAX for sysCharMask (OMX-328).
       -Applicable since unit version 2.09.380."

    REVISION      "201305100125Z"
    DESCRIPTION
      "-v1.25
       -Fixed incorrect SYNTAX statements for various objects (OMX-314).
       -Applicable since unit version 2.09.380."

    REVISION      "201303150124Z"
    DESCRIPTION
      "-v1.24
       -Renamed sysLocation branch to sysLoc (OMX-198).
       -Applicable since unit version 2.09.240."

    REVISION      "201302060123Z"
    DESCRIPTION
      "-v1.23
       -Added ex10 branch.
       -Renamed telnet* objects.
       -Applicable since unit version 2.09.240."

    REVISION      "201301140122Z"
    DESCRIPTION
      "-v1.22
       -Added evReset branch and associated notification (OMX-83).
       -Applicable since unit version 2.09.220."

    REVISION      "201211260121Z"
    DESCRIPTION
      "-v1.21
       -Fixed backwards pppRoutingEnable/ethRoutingEnable comments.  (BN 4620)"

    REVISION      "201208220120Z"
    DESCRIPTION
      "-v1.20
       -Added additional AC power monitor items."

    REVISION      "201207090119Z"
    DESCRIPTION
      "-v1.19
       -Removed wirelessBand object.
       -Removed secSSH objects."

    REVISION      "201206120118Z"
    DESCRIPTION
      "-v1.18
       -Removed user credentials objects.
       -Added combined power distributor status objects."

    REVISION      "201204090117Z"
    DESCRIPTION
      "-v1.17
       -Added eth2WanRoutingEnable object."

    REVISION      "201204050116Z"
    DESCRIPTION
      "-v1.16
       -Added combined eventsensor status objects."

    REVISION      "201203060115Z"
    DESCRIPTION
      "-v1.15
       -Added objects and trap definitions for fuel sensor and AC power monitor."

    REVISION      "201112050900Z"
    DESCRIPTION
      "-v1.14
       -Added s571StockScriptTrap notification definition."

    REVISION      "201110240900Z"
    DESCRIPTION
      "-v1.13
       -Added s571StockLoadSheddingTrap notification definition."

    REVISION      "201108080900Z"
    DESCRIPTION
      "-v1.12
       -Added s571StockOutputTrap notification definition."

    REVISION      "201108010900Z"
    DESCRIPTION
      "-v1.11
       -Added evMgmtReprocess object."

    REVISION      "201107200900Z"
    DESCRIPTION
      "-v1.10
       -Added aisgStatus branch."

    REVISION      "201107080900Z"
    DESCRIPTION
      "-v1.09
       -Added wirelessModemStatus branch."

    REVISION      "201101050900Z"
    DESCRIPTION
      "-v1.08
       -Added espcCCNormalThreshold object."

    REVISION      "201012010900Z"
    DESCRIPTION
      "-v1.07
       -Added support for PowerBoss external power distributors.  This is in the
       pdNextGen object branch which also supports the internal power distributor
       of the SiteBoss 571.  The old SNMP support for the internal power
       distributor is kept in the older sub-branches of the powerDistributionStatus
       branch (pdConfig, pdMain, pdOutput).  The idea behind the pdNextGen object
       branch is that there are 31 items for power monitoring and alarming, and
       these items are organized in a double-indexed SNMP table object: the first
       index is for the power distributor (and has the same numbering scheme as an
       EventSensor  -- like esIndexES, but is called pdnIndexPD), and the second
       index is the power output to which the item applies (or just '1' if the item
       is not specific to a particular power output).  E.g., to read the main
       current of the internal power distributor, you can use the old object
       (pdMainCurrentValue.0) or you can use the new object
       (pdnMainCurrentValue.200.1).  To read the fuse event state of power output
       number 8 on the power distributor (PowerBoss) at index 2, read
       pdnOutputFuseInEventState.2.8."

    REVISION      "201011030900Z"
    DESCRIPTION
      "-v1.06
       -Changed deadband, threshold, and current values for temperature
       sensors from integer to floating-point type.  This means the
       SNMP object type for the temperature settings (deadbands and
       thresholds) changed from Integer32 to DisplayString.
       -Fixed bug where SNMP integer range defined in the MIB for
       trapIncludedValue was 16-bit instead of 32-bit."

    REVISION      "201008240900Z"
    DESCRIPTION
      "-v1.05
       -Fixed bug where some stock traps had too few varbinds declared.
       -Removed useless trap definitions."

    REVISION      "201003170900Z"
    DESCRIPTION
      "-v1.04
       -Removed useless object consoleInlineHsk.
       -Added asset management object branch.
       -Added altitude location object.
       -Removed all obsolete switch references, made everything consistent
        on outputs (relay outputs or power outputs).
       -Added threshold objects for power distribution sensors.
       -Added pdOutputCurrentValue object.
       -Fixed description for pdOutputCurrentInEventState."

    REVISION      "201001190900Z"
    DESCRIPTION
      "-v1.03
       -Increased range for esPointValueInt"

    REVISION      "200910080900Z"
    DESCRIPTION
      "-v1.02
       -Incremental pre-release changes"

    REVISION      "200910050900Z"
    DESCRIPTION
      "-v1.01
       -Incremental pre-release changes"

    REVISION      "200909170900Z"
    DESCRIPTION
      "-v1.00
       -Initial version."

    ::= { asentria 14 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

MIB module for managing Asentria SiteBoss 571

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 2 matching source records

Evidence

Source records

2 records

Matching descriptions are grouped; representative source files are shown for each definition.

Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)2 records · 2 sources

Description 1

s571 · unspecifiedMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: unspecified.

Names: s571

Technical details
{
  "smi_kind": "MODULE-IDENTITY",
  "definition": [
    "s571",
    "MODULE-IDENTITY",
    "LAST-UPDATED",
    [
      "literal",
      "223230313431323131303134335a22"
    ],
    "ORGANIZATION",
    "\"Asentria Corporation\"",
    "CONTACT-INFO",
    "\"Phone: 206-344-8800 Fax: 206-344-2116 Email: support@asentria.com\"",
    "DESCRIPTION",
    "\"MIB module for managing Asentria SiteBoss 571\"",
    "REVISION",
    [
      "literal",
      "223230313431323131303134335a22"
    ],
    "DESCRIPTION",
    "\"-v1.43 -Changed analog-input fuel sensor objects from Integer32 to DisplayString (OMX-1177). -Added missing ipv6DefaultRouter object (OMX-1175). -Applicable since unit version 2.10.580.\"",
    "REVISION",
    [
      "literal",
      "223230313431303136303134325a22"
    ],
    "DESCRIPTION",
    "\"-v1.42 -Added espcAIDisplayFormat object (OMX-1112). -Removed espcAIPolarity, espcAIConvHighSign, espcAIConvLowSign objects (OMX-1113). -Applicable since unit version 2.10.460.\"",
    "REVISION",
    [
      "literal",
      "223230313431303033303134315a22"
    ],
    "DESCRIPTION",
    "\"-v1.41 -Changed analog input objects from Integer32 to DisplayString. -Applicable since unit version 2.10.460.\"",
    "REVISION",
    [
      "literal",
      "223230313430383134303134305a22"
    ],
    "DESCRIPTION",
    "\"-v1.40 -Fixed description for wirelessConnIP objects (OMX-1061). -Applicable since unit version 2.10.390.\"",
    "REVISION",
    [
      "literal",
      "223230313430373033303133395a22"
    ],
    "DESCRIPTION",
    "\"-v1.39 -Fixed wirelessIdleTimeout (OMX-1037). -Fixed CPE status objects (OMX-1036). -Applicable since unit version 2.10.390.\"",
    "REVISION",
    [
      "literal",
      "223230313430363234303133385a22"
    ],
    "DESCRIPTION",
    "\"-v1.38 -Fixed CPE status objects. -Applicable since unit version 2.10.340.\"",
    "REVISION",
    [
      "literal",
      "223230313430353239303133375a22"
    ],
    "DESCRIPTION",
    "\"-v1.37 -Added various missing objects (OMX-751). -Added CPE objects (OMX-162). -Applicable since unit version 2.10.320.\"",
    "REVISION",
    [
      "literal",
      "223230313430343131303133365a22"
    ],
    "DESCRIPTION",
    "\"-v1.36 -Clarified relay and power output function and documentation (OMX-926). -Applicable since unit version 2.10.300.\"",
    "REVISION",
    [
      "literal",
      "223230313430313137303133355a22"
    ],
    "DESCRIPTION",
    "\"-v1.35 -Added IPv6 objects (OMX-705). -Added power distribution objects (powerDistributionStatus branch) (OMX-708). -Fixed ipRestrictionMask wrong type (OMX-743). -Added ftpPushPermissions (OMX-737). -Added snmpProxy objects (OMX-747). -Applicable since unit version 2.10.150.\"",
    "REVISION",
    [
      "literal",
      "223230313331323034303133345a22"
    ],
    "DESCRIPTION",
    "\"-v1.34 -Added fsGenEnable (OMX-661). -Applicable since unit version 2.10.110.\"",
    "REVISION",
    [
      "literal",
      "223230313330393034303133335a22"
    ],
    "DESCRIPTION",
    "\"-v1.33 -Added pdSystemCurrent and pdSystemPower objects (OMX-527). -Added pdnDeviceCurrentValue and pdnDeviceCurrentValueStr objects (OMX-528). -Applicable since unit version 2.09.626.\"",
    "REVISION",
    [
      "literal",
      "223230313330383031303133325a22"
    ],
    "DESCRIPTION",
    "\"-v1.32 -Added missing trapEventTypeNumber available values in description (OMX-437). -Applicable since unit version 2.09.560.\"",
    "REVISION",
    [
      "literal",
      "223230313330373137303133315a22"
    ],
    "DESCRIPTION",
    "\"-v1.31 -Corrected snmpPBufferAllPeriod object. -Applicable since unit version 2.09.560.\"",
    "REVISION",
    [
      "literal",
      "223230313330373032303133305a22"
    ],
    "DESCRIPTION",
    "\"-v1.30 -Added snmpPoll objects (OMX-394). -Applicable since unit version 2.09.560.\"",
    "REVISION",
    [
      "literal",
      "223230313330363238303132395a22"
    ],
    "DESCRIPTION",
    "\"-v1.29 -Removed Ethernet Expansion card objects. -Applicable since unit version 2.09.540.\"",
    "REVISION",
    [
      "literal",
      "223230313330363133303132385a22"
    ],
    "DESCRIPTION",
    "\"-v1.28 -Added sysFileTransfer and sysUpdate objects. (OMX-42) -Applicable since unit version 2.09.520.\"",
    "REVISION",
    [
      "literal",
      "223230313330363132303132375a22"
    ],
    "DESCRIPTION",
    "\"-v1.27 -Renamed EX10 to Ethernet Expansion (OMX-364) -Applicable since unit version 2.09.510.\"",
    "REVISION",
    [
      "literal",
      "223230313330353238303132365a22"
    ],
    "DESCRIPTION",
    "\"-v1.26 -Fixed incorrect SYNTAX for sysCharMask (OMX-328). -Applicable since unit version 2.09.380.\"",
    "REVISION",
    [
      "literal",
      "223230313330353130303132355a22"
    ],
    "DESCRIPTION",
    "\"-v1.25 -Fixed incorrect SYNTAX statements for various objects (OMX-314). -Applicable since unit version 2.09.380.\"",
    "REVISION",
    [
      "literal",
      "223230313330333135303132345a22"
    ],
    "DESCRIPTION",
    "\"-v1.24 -Renamed sysLocation branch to sysLoc (OMX-198). -Applicable since unit version 2.09.240.\"",
    "REVISION",
    [
      "literal",
      "223230313330323036303132335a22"
    ],
    "DESCRIPTION",
    "\"-v1.23 -Added ex10 branch. -Renamed telnet* objects. -Applicable since unit version 2.09.240.\"",
    "REVISION",
    [
      "literal",
      "223230313330313134303132325a22"
    ],
    "DESCRIPTION",
    "\"-v1.22 -Added evReset branch and associated notification (OMX-83). -Applicable since unit version 2.09.220.\"",
    "REVISION",
    [
      "literal",
      "223230313231313236303132315a22"
    ],
    "DESCRIPTION",
    "\"-v1.21 -Fixed backwards pppRoutingEnable/ethRoutingEnable comments. (BN 4620)\"",
    "REVISION",
    [
      "literal",
      "223230313230383232303132305a22"
    ],
    "DESCRIPTION",
    "\"-v1.20 -Added additional AC power monitor items.\"",
    "REVISION",
    [
      "literal",
      "223230313230373039303131395a22"
    ],
    "DESCRIPTION",
    "\"-v1.19 -Removed wirelessBand object. -Removed secSSH objects.\"",
    "REVISION",
    [
      "literal",
      "223230313230363132303131385a22"
    ],
    "DESCRIPTION",
    "\"-v1.18 -Removed user credentials objects. -Added combined power distributor status objects.\"",
    "REVISION",
    [
      "literal",
      "223230313230343039303131375a22"
    ],
    "DESCRIPTION",
    "\"-v1.17 -Added eth2WanRoutingEnable object.\"",
    "REVISION",
    [
      "literal",
      "223230313230343035303131365a22"
    ],
    "DESCRIPTION",
    "\"-v1.16 -Added combined eventsensor status objects.\"",
    "REVISION",
    [
      "literal",
      "223230313230333036303131355a22"
    ],
    "DESCRIPTION",
    "\"-v1.15 -Added objects and trap definitions for fuel sensor and AC power monitor.\"",
    "REVISION",
    [
      "literal",
      "223230313131323035303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.14 -Added s571StockScriptTrap notification definition.\"",
    "REVISION",
    [
      "literal",
      "223230313131303234303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.13 -Added s571StockLoadSheddingTrap notification definition.\"",
    "REVISION",
    [
      "literal",
      "223230313130383038303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.12 -Added s571StockOutputTrap notification definition.\"",
    "REVISION",
    [
      "literal",
      "223230313130383031303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.11 -Added evMgmtReprocess object.\"",
    "REVISION",
    [
      "literal",
      "223230313130373230303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.10 -Added aisgStatus branch.\"",
    "REVISION",
    [
      "literal",
      "223230313130373038303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.09 -Added wirelessModemStatus branch.\"",
    "REVISION",
    [
      "literal",
      "223230313130313035303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.08 -Added espcCCNormalThreshold object.\"",
    "REVISION",
    [
      "literal",
      "223230313031323031303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.07 -Added support for PowerBoss external power distributors. This is in the pdNextGen object branch which also supports the internal power distributor of the SiteBoss 571. The old SNMP support for the internal power distributor is kept in the older sub-branches of the powerDistributionStatus branch (pdConfig, pdMain, pdOutput). The idea behind the pdNextGen object branch is that there are 31 items for power monitoring and alarming, and these items are organized in a double-indexed SNMP table object: the first index is for the power distributor (and has the same numbering scheme as an EventSensor -- like esIndexES, but is called pdnIndexPD), and the second index is the power output to which the item applies (or just '1' if the item is not specific to a particular power output). E.g., to read the main current of the internal power distributor, you can use the old object (pdMainCurrentValue.0) or you can use the new object (pdnMainCurrentValue.200.1). To read the fuse event state of power output number 8 on the power distributor (PowerBoss) at index 2, read pdnOutputFuseInEventState.2.8.\"",
    "REVISION",
    [
      "literal",
      "223230313031313033303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.06 -Changed deadband, threshold, and current values for temperature sensors from integer to floating-point type. This means the SNMP object type for the temperature settings (deadbands and thresholds) changed from Integer32 to DisplayString. -Fixed bug where SNMP integer range defined in the MIB for trapIncludedValue was 16-bit instead of 32-bit.\"",
    "REVISION",
    [
      "literal",
      "223230313030383234303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.05 -Fixed bug where some stock traps had too few varbinds declared. -Removed useless trap definitions.\"",
    "REVISION",
    [
      "literal",
      "223230313030333137303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.04 -Removed useless object consoleInlineHsk. -Added asset management object branch. -Added altitude location object. -Removed all obsolete switch references, made everything consistent on outputs (relay outputs or power outputs). -Added threshold objects for power distribution sensors. -Added pdOutputCurrentValue object. -Fixed description for pdOutputCurrentInEventState.\"",
    "REVISION",
    [
      "literal",
      "223230313030313139303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.03 -Increased range for esPointValueInt\"",
    "REVISION",
    [
      "literal",
      "223230303931303038303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.02 -Incremental pre-release changes\"",
    "REVISION",
    [
      "literal",
      "223230303931303035303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.01 -Incremental pre-release changes\"",
    "REVISION",
    [
      "literal",
      "223230303930393137303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.00 -Initial version.\"",
    "::=",
    "{",
    "asentria",
    "14",
    "}"
  ],
  "syntax_tree": [
    [
      "LAST-UPDATED",
      "201412110143Z"
    ],
    [
      "ORGANIZATION",
      "Asentria Corporation"
    ],
    [
      "CONTACT-INFO",
      "Phone: 206-344-8800 Fax: 206-344-2116 Email: support@asentria.com"
    ],
    [
      "DESCRIPTION",
      "MIB module for managing Asentria SiteBoss 571"
    ],
    [
      "Revisions",
      [
        [
          "201412110143Z",
          [
            "DESCRIPTION",
            "-v1.43 -Changed analog-input fuel sensor objects from Integer32 to DisplayString (OMX-1177). -Added missing ipv6DefaultRouter object (OMX-1175). -Applicable since unit version 2.10.580."
          ]
        ],
        [
          "201410160142Z",
          [
            "DESCRIPTION",
            "-v1.42 -Added espcAIDisplayFormat object (OMX-1112). -Removed espcAIPolarity, espcAIConvHighSign, espcAIConvLowSign objects (OMX-1113). -Applicable since unit version 2.10.460."
          ]
        ],
        [
          "201410030141Z",
          [
            "DESCRIPTION",
            "-v1.41 -Changed analog input objects from Integer32 to DisplayString. -Applicable since unit version 2.10.460."
          ]
        ],
        [
          "201408140140Z",
          [
            "DESCRIPTION",
            "-v1.40 -Fixed description for wirelessConnIP objects (OMX-1061). -Applicable since unit version 2.10.390."
          ]
        ],
        [
          "201407030139Z",
          [
            "DESCRIPTION",
            "-v1.39 -Fixed wirelessIdleTimeout (OMX-1037). -Fixed CPE status objects (OMX-1036). -Applicable since unit version 2.10.390."
          ]
        ],
        [
          "201406240138Z",
          [
            "DESCRIPTION",
            "-v1.38 -Fixed CPE status objects. -Applicable since unit version 2.10.340."
          ]
        ],
        [
          "201405290137Z",
          [
            "DESCRIPTION",
            "-v1.37 -Added various missing objects (OMX-751). -Added CPE objects (OMX-162). -Applicable since unit version 2.10.320."
          ]
        ],
        [
          "201404110136Z",
          [
            "DESCRIPTION",
            "-v1.36 -Clarified relay and power output function and documentation (OMX-926). -Applicable since unit version 2.10.300."
          ]
        ],
        [
          "201401170135Z",
          [
            "DESCRIPTION",
            "-v1.35 -Added IPv6 objects (OMX-705). -Added power distribution objects (powerDistributionStatus branch) (OMX-708). -Fixed ipRestrictionMask wrong type (OMX-743). -Added ftpPushPermissions (OMX-737). -Added snmpProxy objects (OMX-747). -Applicable since unit version 2.10.150."
          ]
        ],
        [
          "201312040134Z",
          [
            "DESCRIPTION",
            "-v1.34 -Added fsGenEnable (OMX-661). -Applicable since unit version 2.10.110."
          ]
        ],
        [
          "201309040133Z",
          [
            "DESCRIPTION",
            "-v1.33 -Added pdSystemCurrent and pdSystemPower objects (OMX-527). -Added pdnDeviceCurrentValue and pdnDeviceCurrentValueStr objects (OMX-528). -Applicable since unit version 2.09.626."
          ]
        ],
        [
          "201308010132Z",
          [
            "DESCRIPTION",
            "-v1.32 -Added missing trapEventTypeNumber available values in description (OMX-437). -Applicable since unit version 2.09.560."
          ]
        ],
        [
          "201307170131Z",
          [
            "DESCRIPTION",
            "-v1.31 -Corrected snmpPBufferAllPeriod object. -Applicable since unit version 2.09.560."
          ]
        ],
        [
          "201307020130Z",
          [
            "DESCRIPTION",
            "-v1.30 -Added snmpPoll objects (OMX-394). -Applicable since unit version 2.09.560."
          ]
        ],
        [
          "201306280129Z",
          [
            "DESCRIPTION",
            "-v1.29 -Removed Ethernet Expansion card objects. -Applicable since unit version 2.09.540."
          ]
        ],
        [
          "201306130128Z",
          [
            "DESCRIPTION",
            "-v1.28 -Added sysFileTransfer and sysUpdate objects. (OMX-42) -Applicable since unit version 2.09.520."
          ]
        ],
        [
          "201306120127Z",
          [
            "DESCRIPTION",
            "-v1.27 -Renamed EX10 to Ethernet Expansion (OMX-364) -Applicable since unit version 2.09.510."
          ]
        ],
        [
          "201305280126Z",
          [
            "DESCRIPTION",
            "-v1.26 -Fixed incorrect SYNTAX for sysCharMask (OMX-328). -Applicable since unit version 2.09.380."
          ]
        ],
        [
          "201305100125Z",
          [
            "DESCRIPTION",
            "-v1.25 -Fixed incorrect SYNTAX statements for various objects (OMX-314). -Applicable since unit version 2.09.380."
          ]
        ],
        [
          "201303150124Z",
          [
            "DESCRIPTION",
            "-v1.24 -Renamed sysLocation branch to sysLoc (OMX-198). -Applicable since unit version 2.09.240."
          ]
        ],
        [
          "201302060123Z",
          [
            "DESCRIPTION",
            "-v1.23 -Added ex10 branch. -Renamed telnet* objects. -Applicable since unit version 2.09.240."
          ]
        ],
        [
          "201301140122Z",
          [
            "DESCRIPTION",
            "-v1.22 -Added evReset branch and associated notification (OMX-83). -Applicable since unit version 2.09.220."
          ]
        ],
        [
          "201211260121Z",
          [
            "DESCRIPTION",
            "-v1.21 -Fixed backwards pppRoutingEnable/ethRoutingEnable comments. (BN 4620)"
          ]
        ],
        [
          "201208220120Z",
          [
            "DESCRIPTION",
            "-v1.20 -Added additional AC power monitor items."
          ]
        ],
        [
          "201207090119Z",
          [
            "DESCRIPTION",
            "-v1.19 -Removed wirelessBand object. -Removed secSSH objects."
          ]
        ],
        [
          "201206120118Z",
          [
            "DESCRIPTION",
            "-v1.18 -Removed user credentials objects. -Added combined power distributor status objects."
          ]
        ],
        [
          "201204090117Z",
          [
            "DESCRIPTION",
            "-v1.17 -Added eth2WanRoutingEnable object."
          ]
        ],
        [
          "201204050116Z",
          [
            "DESCRIPTION",
            "-v1.16 -Added combined eventsensor status objects."
          ]
        ],
        [
          "201203060115Z",
          [
            "DESCRIPTION",
            "-v1.15 -Added objects and trap definitions for fuel sensor and AC power monitor."
          ]
        ],
        [
          "201112050900Z",
          [
            "DESCRIPTION",
            "-v1.14 -Added s571StockScriptTrap notification definition."
          ]
        ],
        [
          "201110240900Z",
          [
            "DESCRIPTION",
            "-v1.13 -Added s571StockLoadSheddingTrap notification definition."
          ]
        ],
        [
          "201108080900Z",
          [
            "DESCRIPTION",
            "-v1.12 -Added s571StockOutputTrap notification definition."
          ]
        ],
        [
          "201108010900Z",
          [
            "DESCRIPTION",
            "-v1.11 -Added evMgmtReprocess object."
          ]
        ],
        [
          "201107200900Z",
          [
            "DESCRIPTION",
            "-v1.10 -Added aisgStatus branch."
          ]
        ],
        [
          "201107080900Z",
          [
            "DESCRIPTION",
            "-v1.09 -Added wirelessModemStatus branch."
          ]
        ],
        [
          "201101050900Z",
          [
            "DESCRIPTION",
            "-v1.08 -Added espcCCNormalThreshold object."
          ]
        ],
        [
          "201012010900Z",
          [
            "DESCRIPTION",
            "-v1.07 -Added support for PowerBoss external power distributors. This is in the pdNextGen object branch which also supports the internal power distributor of the SiteBoss 571. The old SNMP support for the internal power distributor is kept in the older sub-branches of the powerDistributionStatus branch (pdConfig, pdMain, pdOutput). The idea behind the pdNextGen object branch is that there are 31 items for power monitoring and alarming, and these items are organized in a double-indexed SNMP table object: the first index is for the power distributor (and has the same numbering scheme as an EventSensor -- like esIndexES, but is called pdnIndexPD), and the second index is the power output to which the item applies (or just '1' if the item is not specific to a particular power output). E.g., to read the main current of the internal power distributor, you can use the old object (pdMainCurrentValue.0) or you can use the new object (pdnMainCurrentValue.200.1). To read the fuse event state of power output number 8 on the power distributor (PowerBoss) at index 2, read pdnOutputFuseInEventState.2.8."
          ]
        ],
        [
          "201011030900Z",
          [
            "DESCRIPTION",
            "-v1.06 -Changed deadband, threshold, and current values for temperature sensors from integer to floating-point type. This means the SNMP object type for the temperature settings (deadbands and thresholds) changed from Integer32 to DisplayString. -Fixed bug where SNMP integer range defined in the MIB for trapIncludedValue was 16-bit instead of 32-bit."
          ]
        ],
        [
          "201008240900Z",
          [
            "DESCRIPTION",
            "-v1.05 -Fixed bug where some stock traps had too few varbinds declared. -Removed useless trap definitions."
          ]
        ],
        [
          "201003170900Z",
          [
            "DESCRIPTION",
            "-v1.04 -Removed useless object consoleInlineHsk. -Added asset management object branch. -Added altitude location object. -Removed all obsolete switch references, made everything consistent on outputs (relay outputs or power outputs). -Added threshold objects for power distribution sensors. -Added pdOutputCurrentValue object. -Fixed description for pdOutputCurrentInEventState."
          ]
        ],
        [
          "201001190900Z",
          [
            "DESCRIPTION",
            "-v1.03 -Increased range for esPointValueInt"
          ]
        ],
        [
          "200910080900Z",
          [
            "DESCRIPTION",
            "-v1.02 -Incremental pre-release changes"
          ]
        ],
        [
          "200910050900Z",
          [
            "DESCRIPTION",
            "-v1.01 -Incremental pre-release changes"
          ]
        ],
        [
          "200909170900Z",
          [
            "DESCRIPTION",
            "-v1.00 -Initial version."
          ]
        ]
      ]
    ]
  ]
}
s571 · unspecifiedMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: unspecified.

Names: s571

Technical details
{
  "smi_kind": "MODULE-IDENTITY",
  "definition": [
    "s571",
    "MODULE-IDENTITY",
    "LAST-UPDATED",
    [
      "literal",
      "223230313431323330303134345a22"
    ],
    "ORGANIZATION",
    "\"Asentria Corporation\"",
    "CONTACT-INFO",
    "\"Phone: 206-344-8800 Fax: 206-344-2116 Email: support@asentria.com\"",
    "DESCRIPTION",
    "\"MIB module for managing Asentria SiteBoss 571\"",
    "REVISION",
    [
      "literal",
      "223230313431323330303134345a22"
    ],
    "DESCRIPTION",
    "\"-v1.44 -Removed wirelessPIN and scSecret objects (OMX-1064). -Applicable since unit version 2.10.610.\"",
    "REVISION",
    [
      "literal",
      "223230313431323131303134335a22"
    ],
    "DESCRIPTION",
    "\"-v1.43 -Changed analog-input fuel sensor objects from Integer32 to DisplayString (OMX-1177). -Added missing ipv6DefaultRouter object (OMX-1175). -Applicable since unit version 2.10.580.\"",
    "REVISION",
    [
      "literal",
      "223230313431303136303134325a22"
    ],
    "DESCRIPTION",
    "\"-v1.42 -Added espcAIDisplayFormat object (OMX-1112). -Removed espcAIPolarity, espcAIConvHighSign, espcAIConvLowSign objects (OMX-1113). -Applicable since unit version 2.10.460.\"",
    "REVISION",
    [
      "literal",
      "223230313431303033303134315a22"
    ],
    "DESCRIPTION",
    "\"-v1.41 -Changed analog input objects from Integer32 to DisplayString. -Applicable since unit version 2.10.460.\"",
    "REVISION",
    [
      "literal",
      "223230313430383134303134305a22"
    ],
    "DESCRIPTION",
    "\"-v1.40 -Fixed description for wirelessConnIP objects (OMX-1061). -Applicable since unit version 2.10.390.\"",
    "REVISION",
    [
      "literal",
      "223230313430373033303133395a22"
    ],
    "DESCRIPTION",
    "\"-v1.39 -Fixed wirelessIdleTimeout (OMX-1037). -Fixed CPE status objects (OMX-1036). -Applicable since unit version 2.10.390.\"",
    "REVISION",
    [
      "literal",
      "223230313430363234303133385a22"
    ],
    "DESCRIPTION",
    "\"-v1.38 -Fixed CPE status objects. -Applicable since unit version 2.10.340.\"",
    "REVISION",
    [
      "literal",
      "223230313430353239303133375a22"
    ],
    "DESCRIPTION",
    "\"-v1.37 -Added various missing objects (OMX-751). -Added CPE objects (OMX-162). -Applicable since unit version 2.10.320.\"",
    "REVISION",
    [
      "literal",
      "223230313430343131303133365a22"
    ],
    "DESCRIPTION",
    "\"-v1.36 -Clarified relay and power output function and documentation (OMX-926). -Applicable since unit version 2.10.300.\"",
    "REVISION",
    [
      "literal",
      "223230313430313137303133355a22"
    ],
    "DESCRIPTION",
    "\"-v1.35 -Added IPv6 objects (OMX-705). -Added power distribution objects (powerDistributionStatus branch) (OMX-708). -Fixed ipRestrictionMask wrong type (OMX-743). -Added ftpPushPermissions (OMX-737). -Added snmpProxy objects (OMX-747). -Applicable since unit version 2.10.150.\"",
    "REVISION",
    [
      "literal",
      "223230313331323034303133345a22"
    ],
    "DESCRIPTION",
    "\"-v1.34 -Added fsGenEnable (OMX-661). -Applicable since unit version 2.10.110.\"",
    "REVISION",
    [
      "literal",
      "223230313330393034303133335a22"
    ],
    "DESCRIPTION",
    "\"-v1.33 -Added pdSystemCurrent and pdSystemPower objects (OMX-527). -Added pdnDeviceCurrentValue and pdnDeviceCurrentValueStr objects (OMX-528). -Applicable since unit version 2.09.626.\"",
    "REVISION",
    [
      "literal",
      "223230313330383031303133325a22"
    ],
    "DESCRIPTION",
    "\"-v1.32 -Added missing trapEventTypeNumber available values in description (OMX-437). -Applicable since unit version 2.09.560.\"",
    "REVISION",
    [
      "literal",
      "223230313330373137303133315a22"
    ],
    "DESCRIPTION",
    "\"-v1.31 -Corrected snmpPBufferAllPeriod object. -Applicable since unit version 2.09.560.\"",
    "REVISION",
    [
      "literal",
      "223230313330373032303133305a22"
    ],
    "DESCRIPTION",
    "\"-v1.30 -Added snmpPoll objects (OMX-394). -Applicable since unit version 2.09.560.\"",
    "REVISION",
    [
      "literal",
      "223230313330363238303132395a22"
    ],
    "DESCRIPTION",
    "\"-v1.29 -Removed Ethernet Expansion card objects. -Applicable since unit version 2.09.540.\"",
    "REVISION",
    [
      "literal",
      "223230313330363133303132385a22"
    ],
    "DESCRIPTION",
    "\"-v1.28 -Added sysFileTransfer and sysUpdate objects. (OMX-42) -Applicable since unit version 2.09.520.\"",
    "REVISION",
    [
      "literal",
      "223230313330363132303132375a22"
    ],
    "DESCRIPTION",
    "\"-v1.27 -Renamed EX10 to Ethernet Expansion (OMX-364) -Applicable since unit version 2.09.510.\"",
    "REVISION",
    [
      "literal",
      "223230313330353238303132365a22"
    ],
    "DESCRIPTION",
    "\"-v1.26 -Fixed incorrect SYNTAX for sysCharMask (OMX-328). -Applicable since unit version 2.09.380.\"",
    "REVISION",
    [
      "literal",
      "223230313330353130303132355a22"
    ],
    "DESCRIPTION",
    "\"-v1.25 -Fixed incorrect SYNTAX statements for various objects (OMX-314). -Applicable since unit version 2.09.380.\"",
    "REVISION",
    [
      "literal",
      "223230313330333135303132345a22"
    ],
    "DESCRIPTION",
    "\"-v1.24 -Renamed sysLocation branch to sysLoc (OMX-198). -Applicable since unit version 2.09.240.\"",
    "REVISION",
    [
      "literal",
      "223230313330323036303132335a22"
    ],
    "DESCRIPTION",
    "\"-v1.23 -Added ex10 branch. -Renamed telnet* objects. -Applicable since unit version 2.09.240.\"",
    "REVISION",
    [
      "literal",
      "223230313330313134303132325a22"
    ],
    "DESCRIPTION",
    "\"-v1.22 -Added evReset branch and associated notification (OMX-83). -Applicable since unit version 2.09.220.\"",
    "REVISION",
    [
      "literal",
      "223230313231313236303132315a22"
    ],
    "DESCRIPTION",
    "\"-v1.21 -Fixed backwards pppRoutingEnable/ethRoutingEnable comments. (BN 4620)\"",
    "REVISION",
    [
      "literal",
      "223230313230383232303132305a22"
    ],
    "DESCRIPTION",
    "\"-v1.20 -Added additional AC power monitor items.\"",
    "REVISION",
    [
      "literal",
      "223230313230373039303131395a22"
    ],
    "DESCRIPTION",
    "\"-v1.19 -Removed wirelessBand object. -Removed secSSH objects.\"",
    "REVISION",
    [
      "literal",
      "223230313230363132303131385a22"
    ],
    "DESCRIPTION",
    "\"-v1.18 -Removed user credentials objects. -Added combined power distributor status objects.\"",
    "REVISION",
    [
      "literal",
      "223230313230343039303131375a22"
    ],
    "DESCRIPTION",
    "\"-v1.17 -Added eth2WanRoutingEnable object.\"",
    "REVISION",
    [
      "literal",
      "223230313230343035303131365a22"
    ],
    "DESCRIPTION",
    "\"-v1.16 -Added combined eventsensor status objects.\"",
    "REVISION",
    [
      "literal",
      "223230313230333036303131355a22"
    ],
    "DESCRIPTION",
    "\"-v1.15 -Added objects and trap definitions for fuel sensor and AC power monitor.\"",
    "REVISION",
    [
      "literal",
      "223230313131323035303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.14 -Added s571StockScriptTrap notification definition.\"",
    "REVISION",
    [
      "literal",
      "223230313131303234303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.13 -Added s571StockLoadSheddingTrap notification definition.\"",
    "REVISION",
    [
      "literal",
      "223230313130383038303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.12 -Added s571StockOutputTrap notification definition.\"",
    "REVISION",
    [
      "literal",
      "223230313130383031303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.11 -Added evMgmtReprocess object.\"",
    "REVISION",
    [
      "literal",
      "223230313130373230303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.10 -Added aisgStatus branch.\"",
    "REVISION",
    [
      "literal",
      "223230313130373038303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.09 -Added wirelessModemStatus branch.\"",
    "REVISION",
    [
      "literal",
      "223230313130313035303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.08 -Added espcCCNormalThreshold object.\"",
    "REVISION",
    [
      "literal",
      "223230313031323031303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.07 -Added support for PowerBoss external power distributors. This is in the pdNextGen object branch which also supports the internal power distributor of the SiteBoss 571. The old SNMP support for the internal power distributor is kept in the older sub-branches of the powerDistributionStatus branch (pdConfig, pdMain, pdOutput). The idea behind the pdNextGen object branch is that there are 31 items for power monitoring and alarming, and these items are organized in a double-indexed SNMP table object: the first index is for the power distributor (and has the same numbering scheme as an EventSensor -- like esIndexES, but is called pdnIndexPD), and the second index is the power output to which the item applies (or just '1' if the item is not specific to a particular power output). E.g., to read the main current of the internal power distributor, you can use the old object (pdMainCurrentValue.0) or you can use the new object (pdnMainCurrentValue.200.1). To read the fuse event state of power output number 8 on the power distributor (PowerBoss) at index 2, read pdnOutputFuseInEventState.2.8.\"",
    "REVISION",
    [
      "literal",
      "223230313031313033303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.06 -Changed deadband, threshold, and current values for temperature sensors from integer to floating-point type. This means the SNMP object type for the temperature settings (deadbands and thresholds) changed from Integer32 to DisplayString. -Fixed bug where SNMP integer range defined in the MIB for trapIncludedValue was 16-bit instead of 32-bit.\"",
    "REVISION",
    [
      "literal",
      "223230313030383234303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.05 -Fixed bug where some stock traps had too few varbinds declared. -Removed useless trap definitions.\"",
    "REVISION",
    [
      "literal",
      "223230313030333137303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.04 -Removed useless object consoleInlineHsk. -Added asset management object branch. -Added altitude location object. -Removed all obsolete switch references, made everything consistent on outputs (relay outputs or power outputs). -Added threshold objects for power distribution sensors. -Added pdOutputCurrentValue object. -Fixed description for pdOutputCurrentInEventState.\"",
    "REVISION",
    [
      "literal",
      "223230313030313139303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.03 -Increased range for esPointValueInt\"",
    "REVISION",
    [
      "literal",
      "223230303931303038303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.02 -Incremental pre-release changes\"",
    "REVISION",
    [
      "literal",
      "223230303931303035303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.01 -Incremental pre-release changes\"",
    "REVISION",
    [
      "literal",
      "223230303930393137303930305a22"
    ],
    "DESCRIPTION",
    "\"-v1.00 -Initial version.\"",
    "::=",
    "{",
    "asentria",
    "14",
    "}"
  ],
  "syntax_tree": [
    [
      "LAST-UPDATED",
      "201412300144Z"
    ],
    [
      "ORGANIZATION",
      "Asentria Corporation"
    ],
    [
      "CONTACT-INFO",
      "Phone: 206-344-8800 Fax: 206-344-2116 Email: support@asentria.com"
    ],
    [
      "DESCRIPTION",
      "MIB module for managing Asentria SiteBoss 571"
    ],
    [
      "Revisions",
      [
        [
          "201412300144Z",
          [
            "DESCRIPTION",
            "-v1.44 -Removed wirelessPIN and scSecret objects (OMX-1064). -Applicable since unit version 2.10.610."
          ]
        ],
        [
          "201412110143Z",
          [
            "DESCRIPTION",
            "-v1.43 -Changed analog-input fuel sensor objects from Integer32 to DisplayString (OMX-1177). -Added missing ipv6DefaultRouter object (OMX-1175). -Applicable since unit version 2.10.580."
          ]
        ],
        [
          "201410160142Z",
          [
            "DESCRIPTION",
            "-v1.42 -Added espcAIDisplayFormat object (OMX-1112). -Removed espcAIPolarity, espcAIConvHighSign, espcAIConvLowSign objects (OMX-1113). -Applicable since unit version 2.10.460."
          ]
        ],
        [
          "201410030141Z",
          [
            "DESCRIPTION",
            "-v1.41 -Changed analog input objects from Integer32 to DisplayString. -Applicable since unit version 2.10.460."
          ]
        ],
        [
          "201408140140Z",
          [
            "DESCRIPTION",
            "-v1.40 -Fixed description for wirelessConnIP objects (OMX-1061). -Applicable since unit version 2.10.390."
          ]
        ],
        [
          "201407030139Z",
          [
            "DESCRIPTION",
            "-v1.39 -Fixed wirelessIdleTimeout (OMX-1037). -Fixed CPE status objects (OMX-1036). -Applicable since unit version 2.10.390."
          ]
        ],
        [
          "201406240138Z",
          [
            "DESCRIPTION",
            "-v1.38 -Fixed CPE status objects. -Applicable since unit version 2.10.340."
          ]
        ],
        [
          "201405290137Z",
          [
            "DESCRIPTION",
            "-v1.37 -Added various missing objects (OMX-751). -Added CPE objects (OMX-162). -Applicable since unit version 2.10.320."
          ]
        ],
        [
          "201404110136Z",
          [
            "DESCRIPTION",
            "-v1.36 -Clarified relay and power output function and documentation (OMX-926). -Applicable since unit version 2.10.300."
          ]
        ],
        [
          "201401170135Z",
          [
            "DESCRIPTION",
            "-v1.35 -Added IPv6 objects (OMX-705). -Added power distribution objects (powerDistributionStatus branch) (OMX-708). -Fixed ipRestrictionMask wrong type (OMX-743). -Added ftpPushPermissions (OMX-737). -Added snmpProxy objects (OMX-747). -Applicable since unit version 2.10.150."
          ]
        ],
        [
          "201312040134Z",
          [
            "DESCRIPTION",
            "-v1.34 -Added fsGenEnable (OMX-661). -Applicable since unit version 2.10.110."
          ]
        ],
        [
          "201309040133Z",
          [
            "DESCRIPTION",
            "-v1.33 -Added pdSystemCurrent and pdSystemPower objects (OMX-527). -Added pdnDeviceCurrentValue and pdnDeviceCurrentValueStr objects (OMX-528). -Applicable since unit version 2.09.626."
          ]
        ],
        [
          "201308010132Z",
          [
            "DESCRIPTION",
            "-v1.32 -Added missing trapEventTypeNumber available values in description (OMX-437). -Applicable since unit version 2.09.560."
          ]
        ],
        [
          "201307170131Z",
          [
            "DESCRIPTION",
            "-v1.31 -Corrected snmpPBufferAllPeriod object. -Applicable since unit version 2.09.560."
          ]
        ],
        [
          "201307020130Z",
          [
            "DESCRIPTION",
            "-v1.30 -Added snmpPoll objects (OMX-394). -Applicable since unit version 2.09.560."
          ]
        ],
        [
          "201306280129Z",
          [
            "DESCRIPTION",
            "-v1.29 -Removed Ethernet Expansion card objects. -Applicable since unit version 2.09.540."
          ]
        ],
        [
          "201306130128Z",
          [
            "DESCRIPTION",
            "-v1.28 -Added sysFileTransfer and sysUpdate objects. (OMX-42) -Applicable since unit version 2.09.520."
          ]
        ],
        [
          "201306120127Z",
          [
            "DESCRIPTION",
            "-v1.27 -Renamed EX10 to Ethernet Expansion (OMX-364) -Applicable since unit version 2.09.510."
          ]
        ],
        [
          "201305280126Z",
          [
            "DESCRIPTION",
            "-v1.26 -Fixed incorrect SYNTAX for sysCharMask (OMX-328). -Applicable since unit version 2.09.380."
          ]
        ],
        [
          "201305100125Z",
          [
            "DESCRIPTION",
            "-v1.25 -Fixed incorrect SYNTAX statements for various objects (OMX-314). -Applicable since unit version 2.09.380."
          ]
        ],
        [
          "201303150124Z",
          [
            "DESCRIPTION",
            "-v1.24 -Renamed sysLocation branch to sysLoc (OMX-198). -Applicable since unit version 2.09.240."
          ]
        ],
        [
          "201302060123Z",
          [
            "DESCRIPTION",
            "-v1.23 -Added ex10 branch. -Renamed telnet* objects. -Applicable since unit version 2.09.240."
          ]
        ],
        [
          "201301140122Z",
          [
            "DESCRIPTION",
            "-v1.22 -Added evReset branch and associated notification (OMX-83). -Applicable since unit version 2.09.220."
          ]
        ],
        [
          "201211260121Z",
          [
            "DESCRIPTION",
            "-v1.21 -Fixed backwards pppRoutingEnable/ethRoutingEnable comments. (BN 4620)"
          ]
        ],
        [
          "201208220120Z",
          [
            "DESCRIPTION",
            "-v1.20 -Added additional AC power monitor items."
          ]
        ],
        [
          "201207090119Z",
          [
            "DESCRIPTION",
            "-v1.19 -Removed wirelessBand object. -Removed secSSH objects."
          ]
        ],
        [
          "201206120118Z",
          [
            "DESCRIPTION",
            "-v1.18 -Removed user credentials objects. -Added combined power distributor status objects."
          ]
        ],
        [
          "201204090117Z",
          [
            "DESCRIPTION",
            "-v1.17 -Added eth2WanRoutingEnable object."
          ]
        ],
        [
          "201204050116Z",
          [
            "DESCRIPTION",
            "-v1.16 -Added combined eventsensor status objects."
          ]
        ],
        [
          "201203060115Z",
          [
            "DESCRIPTION",
            "-v1.15 -Added objects and trap definitions for fuel sensor and AC power monitor."
          ]
        ],
        [
          "201112050900Z",
          [
            "DESCRIPTION",
            "-v1.14 -Added s571StockScriptTrap notification definition."
          ]
        ],
        [
          "201110240900Z",
          [
            "DESCRIPTION",
            "-v1.13 -Added s571StockLoadSheddingTrap notification definition."
          ]
        ],
        [
          "201108080900Z",
          [
            "DESCRIPTION",
            "-v1.12 -Added s571StockOutputTrap notification definition."
          ]
        ],
        [
          "201108010900Z",
          [
            "DESCRIPTION",
            "-v1.11 -Added evMgmtReprocess object."
          ]
        ],
        [
          "201107200900Z",
          [
            "DESCRIPTION",
            "-v1.10 -Added aisgStatus branch."
          ]
        ],
        [
          "201107080900Z",
          [
            "DESCRIPTION",
            "-v1.09 -Added wirelessModemStatus branch."
          ]
        ],
        [
          "201101050900Z",
          [
            "DESCRIPTION",
            "-v1.08 -Added espcCCNormalThreshold object."
          ]
        ],
        [
          "201012010900Z",
          [
            "DESCRIPTION",
            "-v1.07 -Added support for PowerBoss external power distributors. This is in the pdNextGen object branch which also supports the internal power distributor of the SiteBoss 571. The old SNMP support for the internal power distributor is kept in the older sub-branches of the powerDistributionStatus branch (pdConfig, pdMain, pdOutput). The idea behind the pdNextGen object branch is that there are 31 items for power monitoring and alarming, and these items are organized in a double-indexed SNMP table object: the first index is for the power distributor (and has the same numbering scheme as an EventSensor -- like esIndexES, but is called pdnIndexPD), and the second index is the power output to which the item applies (or just '1' if the item is not specific to a particular power output). E.g., to read the main current of the internal power distributor, you can use the old object (pdMainCurrentValue.0) or you can use the new object (pdnMainCurrentValue.200.1). To read the fuse event state of power output number 8 on the power distributor (PowerBoss) at index 2, read pdnOutputFuseInEventState.2.8."
          ]
        ],
        [
          "201011030900Z",
          [
            "DESCRIPTION",
            "-v1.06 -Changed deadband, threshold, and current values for temperature sensors from integer to floating-point type. This means the SNMP object type for the temperature settings (deadbands and thresholds) changed from Integer32 to DisplayString. -Fixed bug where SNMP integer range defined in the MIB for trapIncludedValue was 16-bit instead of 32-bit."
          ]
        ],
        [
          "201008240900Z",
          [
            "DESCRIPTION",
            "-v1.05 -Fixed bug where some stock traps had too few varbinds declared. -Removed useless trap definitions."
          ]
        ],
        [
          "201003170900Z",
          [
            "DESCRIPTION",
            "-v1.04 -Removed useless object consoleInlineHsk. -Added asset management object branch. -Added altitude location object. -Removed all obsolete switch references, made everything consistent on outputs (relay outputs or power outputs). -Added threshold objects for power distribution sensors. -Added pdOutputCurrentValue object. -Fixed description for pdOutputCurrentInEventState."
          ]
        ],
        [
          "201001190900Z",
          [
            "DESCRIPTION",
            "-v1.03 -Increased range for esPointValueInt"
          ]
        ],
        [
          "200910080900Z",
          [
            "DESCRIPTION",
            "-v1.02 -Incremental pre-release changes"
          ]
        ],
        [
          "200910050900Z",
          [
            "DESCRIPTION",
            "-v1.01 -Incremental pre-release changes"
          ]
        ],
        [
          "200909170900Z",
          [
            "DESCRIPTION",
            "-v1.00 -Initial version."
          ]
        ]
      ]
    ]
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.3052)

Renton Paul

Direct children (231)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.3052.14.1069 s571UserTrap106900
1.3.6.1.4.1.3052.14.1070 s571UserTrap107000
1.3.6.1.4.1.3052.14.1071 s571UserTrap107100
1.3.6.1.4.1.3052.14.1072 s571UserTrap107200
1.3.6.1.4.1.3052.14.1073 s571UserTrap107300
1.3.6.1.4.1.3052.14.1074 s571UserTrap107400
1.3.6.1.4.1.3052.14.1075 s571UserTrap107500
1.3.6.1.4.1.3052.14.1076 s571UserTrap107600
1.3.6.1.4.1.3052.14.1077 s571UserTrap107700
1.3.6.1.4.1.3052.14.1078 s571UserTrap107800
1.3.6.1.4.1.3052.14.1079 s571UserTrap107900
1.3.6.1.4.1.3052.14.1080 s571UserTrap108000
1.3.6.1.4.1.3052.14.1081 s571UserTrap108100
1.3.6.1.4.1.3052.14.1082 s571UserTrap108200
1.3.6.1.4.1.3052.14.1083 s571UserTrap108300
1.3.6.1.4.1.3052.14.1084 s571UserTrap108400
1.3.6.1.4.1.3052.14.1085 s571UserTrap108500
1.3.6.1.4.1.3052.14.1086 s571UserTrap108600
1.3.6.1.4.1.3052.14.1087 s571UserTrap108700
1.3.6.1.4.1.3052.14.1088 s571UserTrap108800
1.3.6.1.4.1.3052.14.1089 s571UserTrap108900
1.3.6.1.4.1.3052.14.1090 s571UserTrap109000
1.3.6.1.4.1.3052.14.1091 s571UserTrap109100
1.3.6.1.4.1.3052.14.1092 s571UserTrap109200
1.3.6.1.4.1.3052.14.1093 s571UserTrap109300
1.3.6.1.4.1.3052.14.1094 s571UserTrap109400
1.3.6.1.4.1.3052.14.1095 s571UserTrap109500
1.3.6.1.4.1.3052.14.1096 s571UserTrap109600
1.3.6.1.4.1.3052.14.1097 s571UserTrap109700
1.3.6.1.4.1.3052.14.1098 s571UserTrap109800
1.3.6.1.4.1.3052.14.1099 s571UserTrap109900
1.3.6.1.4.1.3052.14.1100 s571UserTrap110000
1.3.6.1.4.1.3052.14.1101 s571UserTrap110100
1.3.6.1.4.1.3052.14.1102 s571UserTrap110200
1.3.6.1.4.1.3052.14.1103 s571UserTrap110300
1.3.6.1.4.1.3052.14.1104 s571UserTrap110400
1.3.6.1.4.1.3052.14.1105 s571UserTrap110500
1.3.6.1.4.1.3052.14.1106 s571UserTrap110600
1.3.6.1.4.1.3052.14.1107 s571UserTrap110700
1.3.6.1.4.1.3052.14.1108 s571UserTrap110800
1.3.6.1.4.1.3052.14.1109 s571UserTrap110900
1.3.6.1.4.1.3052.14.1110 s571UserTrap111000
1.3.6.1.4.1.3052.14.1111 s571UserTrap111100
1.3.6.1.4.1.3052.14.1112 s571UserTrap111200
1.3.6.1.4.1.3052.14.1113 s571UserTrap111300
1.3.6.1.4.1.3052.14.1114 s571UserTrap111400
1.3.6.1.4.1.3052.14.1115 s571UserTrap111500
1.3.6.1.4.1.3052.14.1116 s571UserTrap111600
1.3.6.1.4.1.3052.14.1117 s571UserTrap111700
1.3.6.1.4.1.3052.14.1118 s571UserTrap111800

Siblings (25)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.3052.1 datalink19379
1.3.6.1.4.1.3052.3 dl209419
1.3.6.1.4.1.3052.4 sl61211565
1.3.6.1.4.1.3052.5 sl81213571
1.3.6.1.4.1.3052.6 dl150215451
1.3.6.1.4.1.3052.7 dl80215451
1.3.6.1.4.1.3052.8 s5702261390
1.3.6.1.4.1.3052.10 s55052205
1.3.6.1.4.1.3052.12 s5302281302
1.3.6.1.4.1.3052.17 s45051489
1.3.6.1.4.1.3052.18 s35051652
1.3.6.1.4.1.3052.20 s57251499
1.3.6.1.4.1.3052.23 s36052239
1.3.6.1.4.1.3052.40 s410, sl1069343 S410
1.3.6.1.4.1.3052.41 s412, sl1263296
1.3.6.1.4.1.3052.42 s4208133
1.3.6.1.4.1.3052.43 s2208133
1.3.6.1.4.1.3052.501 datalinkDbasePfullTrap00
1.3.6.1.4.1.3052.502 datalinkFilePfullTrap00
1.3.6.1.4.1.3052.503 datalinkDataAlarmTrap00
1.3.6.1.4.1.3052.504 datalinkSensorAlarmTrap00
1.3.6.1.4.1.3052.505 datalinkNoDataAlarmTrap00
1.3.6.1.4.1.3052.506 datalinkSchedTrap00
1.3.6.1.4.1.3052.507 datalinkImmediateTrap00
1.3.6.1.4.1.3052.509 datalinkPPPupTrap00