Status in source: current.
Names: modRx1MonAlarms
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"modRx1MonAlarms",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"Bitmap encoding of the current alarm status of the Rx1 module. All bits are encoded as 0=NoAlarm 1=Alarm Bit 0: Major Alarm 1: Minor Alarm 2: Automatic Gain Control (AGC) Alarm 3-7: Unused Bit 8: Supply Voltage Alarm 9: Received Light Level Alarm 10: RF Level Alarm 11: RF Gain Alarm 12: BUC Alarm 13: Module Temperature Alarm 14-15: Unused\"",
"::=",
"{",
"slotsEntry",
"145",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Bitmap encoding of the current alarm status of the Rx1 module. All bits are encoded as 0=NoAlarm 1=Alarm Bit 0: Major Alarm 1: Minor Alarm 2: Automatic Gain Control (AGC) Alarm 3-7: Unused Bit 8: Supply Voltage Alarm 9: Received Light Level Alarm 10: RF Level Alarm 11: RF Gain Alarm 12: BUC Alarm 13: Module Temperature Alarm 14-15: Unused"
],
null,
null,
null,
null
]
}