GUID of variable.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.31770.2.2.8.2.1.1
GUID of variable.
Identification
{1 3 6 1 4 1 31770 2 2 8 2 1 1}
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.
In BACHMANN-BLUENET2-MIB, the row index blueNet2VariableId is declared as OCTET STRING. The fixed-length string is encoded as 8 numeric subidentifiers, one per octet. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.
A query example is omitted because the source variants do not establish compatible read access.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
blueNet2VariableId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (8..8))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "GUID of variable."
::= { blueNet2VariableEntry 1 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
GUID of variable.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: blueNet2VariableId
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"blueNet2VariableId",
"OBJECT-TYPE",
"SYNTAX",
"OCTET",
"STRING",
"(",
"SIZE",
"(",
"8",
".",
".",
"8",
")",
")",
"MAX-ACCESS",
"not-accessible",
"STATUS",
"current",
"DESCRIPTION",
"\"GUID of variable.\"",
"::=",
"{",
"blueNet2VariableEntry",
"1",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"OCTET STRING",
[
"octetStringSubType",
[
[
8,
8
]
]
]
],
null,
[
"MaxAccessPart",
"not-accessible"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"GUID of variable."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: BACHMANN-BLUENET2-MIB
See published definition above
{'SNMPv2-TC': ['DateAndTime', 'DisplayString', 'RowStatus', 'TEXTUAL-CONVENTION'], 'SNMPv2-MIB': ['sysObjectID'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'NOTIFICATION-TYPE', 'OBJECT-TYPE', 'Integer32', 'Unsigned32', 'TimeTicks'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'NOTIFICATION-GROUP', 'OBJECT-GROUP'], 'BACHMANN-SMI-MIB': ['bachmann']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.31770.2.2.8.2.1.2 | blueNet2VariableGuid | 0 | 0 | |
| 1.3.6.1.4.1.31770.2.2.8.2.1.3 | blueNet2VariableName | 0 | 0 | |
| 1.3.6.1.4.1.31770.2.2.8.2.1.4 | blueNet2VariableFriendlyName | 0 | 0 | |
| 1.3.6.1.4.1.31770.2.2.8.2.1.5 | blueNet2VariableDescription | 0 | 0 | |
| 1.3.6.1.4.1.31770.2.2.8.2.1.6 | blueNet2VariableType | 0 | 0 | |
| 1.3.6.1.4.1.31770.2.2.8.2.1.7 | blueNet2VariableStatus | 0 | 0 | |
| 1.3.6.1.4.1.31770.2.2.8.2.1.8 | blueNet2VariableAlarm | 0 | 0 | |
| 1.3.6.1.4.1.31770.2.2.8.2.1.9 | blueNet2VariableScaling | 0 | 0 | |
| 1.3.6.1.4.1.31770.2.2.8.2.1.10 | blueNet2VariableUnit | 0 | 0 | |
| 1.3.6.1.4.1.31770.2.2.8.2.1.11 | blueNet2VariableSetPoint | 0 | 0 | |
| 1.3.6.1.4.1.31770.2.2.8.2.1.12 | blueNet2VariableMode | 0 | 0 | |
| 1.3.6.1.4.1.31770.2.2.8.2.1.13 | blueNet2VariableEntPhysicalIndex | 0 | 0 |