During a reboot sequence, power is turned off and then
back on. This OID defines the amount of time to wait,
in seconds, after turning the power off, at the start
of the sequence, before turning power back on, at the
end of the reboot sequence.
Allowed range is any value between 5 and 60 seconds (1 minute).
Parsed from file powernet.mib.txt
Company: None
Module: PowerNet-MIB
During a reboot sequence, power is turned off and then
back on. This OID defines the amount of time to wait,
in seconds, after turning the power off, at the start
of the sequence, before turning power back on, at the
end of the reboot sequence.
Allowed range is any value between 5 and 60 seconds (1 minute).
Parsed from file PowerNet-MIB.mib
Module: PowerNet-MIB
rPDUOutletConfigRebootDuration OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "During a reboot sequence, power is turned off and then back on. This OID defines the amount of time to wait, in seconds, after turning the power off, at the start of the sequence, before turning power back on, at the end of the reboot sequence. Allowed range is any value between 5 and 60 seconds (1 minute)." ::= { rPDUOutletConfigEntry 6 }
Vendor: American Power Conversion Corp.
Module: PowerNet-MIB
[Automatically extracted from oidview.com]
rPDUOutletConfigRebootDuration OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "During a reboot sequence, power is turned off and then back on. This OID defines the amount of time to wait, in seconds, after turning the power off, at the start of the sequence, before turning power back on, at the end of the reboot sequence. Allowed range is any value between 5 and 60 seconds (1 minute)." ::= { rPDUOutletConfigEntry 6 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.318.1.1.12.3.4.1.1.1 | rPDUOutletConfigIndex | 0 | 0 | The index to the outlet entry. |
1.3.6.1.4.1.318.1.1.12.3.4.1.1.2 | rPDUOutletConfigOutletName | 0 | 0 | The name of the outlet. The maximum string size is device dependent. An error will be returned if the set request exceeds the ma… |
1.3.6.1.4.1.318.1.1.12.3.4.1.1.3 | rPDUOutletConfigOutletPhase | 0 | 0 | The phase/s associated with this outlet. For single phase devices, this object will always return phase1(1). For 3-phase devices… |
1.3.6.1.4.1.318.1.1.12.3.4.1.1.4 | rPDUOutletConfigPowerOnTime | 0 | 0 | The amount of time (in seconds) the outlet will delay powering on at coldstart or when a command that requires a turn-on delay is… |
1.3.6.1.4.1.318.1.1.12.3.4.1.1.5 | rPDUOutletConfigPowerOffTime | 0 | 0 | rPDUOutletConfigPowerOfftime |
1.3.6.1.4.1.318.1.1.12.3.4.1.1.7 | rPDUOutletConfigOutletBank | 0 | 0 | The bank associated with this outlet. |