The rating of the main input breaker measured in Amps.
Parsed from file powernet.mib.txt
Company: None
Module: PowerNet-MIB
The rating of the main input breaker measured in Amps.
Parsed from file PowerNet-MIB.mib
Module: PowerNet-MIB
xPDUDeviceMainInputBreakerRating OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The rating of the main input breaker measured in Amps." ::= { xPDUDevice 4 }
Vendor: American Power Conversion Corp.
Module: PowerNet-MIB
[Automatically extracted from oidview.com]
xPDUDeviceMainInputBreakerRating OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The rating of the main input breaker measured in Amps." ::= { xPDUDevice 4 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.318.1.1.15.2.4.0 | xPDUDeviceMainInputBreakerRating | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.318.1.1.15.2.1 | xPDUDeviceNominalMainInputVoltage | 1 | 1 | The nominal main input voltage to the PDU. Measured in Volts, line-to-line for a 3-wire (delta) service or line-to-neutral for a… |
1.3.6.1.4.1.318.1.1.15.2.2 | xPDUDeviceServiceType | 1 | 1 | The type of utility input to the PDU. Either 3 wires (delta), or 4 wires (wye). |
1.3.6.1.4.1.318.1.1.15.2.3 | xPDUDeviceNominalOutputVoltage | 1 | 1 | The nominal line-to-neutral output voltage to the load measured in Volts. |
1.3.6.1.4.1.318.1.1.15.2.5 | xPDUDevicePanelBreakerRating | 1 | 1 | The rating of the panel breaker measured in Amps. |
1.3.6.1.4.1.318.1.1.15.2.6 | xPDUDeviceTransformerPresent | 1 | 1 | Indicates whether or not a transformer is installed in the PDU. |
1.3.6.1.4.1.318.1.1.15.2.7 | xPDUDeviceLoadTieBreakerPresent | 1 | 1 | Indicates whether or not a load tie breaker is installed in the PDU. |
1.3.6.1.4.1.318.1.1.15.2.8 | xPDUDeviceLoadTestPortPresent | 1 | 1 | Indicates whether or not a load test port is installed in the PDU. |
1.3.6.1.4.1.318.1.1.15.2.9 | xPDUDeviceFusesPresent | 1 | 1 | Indicates whether or not the UPS feed from the PDU includes fuses. |
1.3.6.1.4.1.318.1.1.15.2.10 | xPDUDeviceFansPresent | 1 | 1 | Indicates whether or not cooling fans are installed in the PDU. |
1.3.6.1.4.1.318.1.1.15.2.11 | xPDUDeviceBypassInputPresent | 1 | 1 | Indicates whether or not the PDU is equipped with a second feed for the UPS's bypass input. |
1.3.6.1.4.1.318.1.1.15.2.12 | xPDUDeviceCrossTieOutputPresent | 1 | 1 | Indicates whether or not the PDU is equipped with a cross-tie output. |
1.3.6.1.4.1.318.1.1.15.2.13 | xPDUDeviceEarthGroundMonitorPresent | 1 | 1 | Indicates whether or not the PDU can provide ground current measurements. |
1.3.6.1.4.1.318.1.1.15.2.14 | xPDUDeviceInfraStruXureType, xPDUDeviceInfraXureType | 1 | 1 | Indicates the configuration of this PDU system. Type-B PDU is in a distributed UPS system and has bypass capabilities. Type-C PDU… |