Description 1
Shows the input frequency deviation in Hertz.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.318.1.1.28.3.1.2.1.10
Shows the input frequency deviation in Hertz.
Identification
{1 3 6 1 4 1 318 1 1 28 3 1 2 1 10}
| Value | Name |
|---|---|
| 1 | freqDeviationOff |
| 2 | freqDeviationPointTwo |
| 3 | freqDeviationPointFive |
| 4 | freqDeviationOne |
| 5 | freqDeviationOnePointFive |
| 6 | freqDeviationTwo |
| 7 | freqDeviationThree |
| 8 | freqDeviationFour |
| 9 | freqDeviationFive |
| 10 | freqDeviationNine |
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.
In PowerNet-MIB, the row index pmmInputMeterIndex is declared as INTEGER. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.318.1.1.28.3.1.2.1.10.<pmmInputMeterIndex>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.318.1.1.28.3.1.2.1.10
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 2 distinct definitions; some records may not include a definition.
pmmInputFrequencyDeviation OBJECT-TYPE
SYNTAX INTEGER{
freqDeviationOff (1),
freqDeviationPointTwo (2),
freqDeviationPointFive (3),
freqDeviationOne (4),
freqDeviationOnePointFive (5),
freqDeviationTwo (6),
freqDeviationThree (7),
freqDeviationFour (8),
freqDeviationFive (9),
freqDeviationNine (10)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Shows the input frequency deviation in Hertz."
::= { pmmInputEntry 10 }pmmInputFrequencyDeviation OBJECT-TYPE
SYNTAX INTEGER{
freqDeviationOff (1),
freqDeviationPointTwo (2),
freqDeviationPointFive (3),
freqDeviationOne (4),
freqDeviationOnePointFive (5),
freqDeviationTwo (6),
freqDeviationThree (7),
freqDeviationFour (8),
freqDeviationFive (9),
freqDeviationNine (10)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Displays the input frequency deviation in Hertz.
Threshold write returns as unsuccessful if one of the breaker threshold
groups does not meet conditions. In this case, read the thresholds
to know which threshold group's write condition is not met.
Threshold needs to be enabled to read value"
::= { pmmInputEntry 10 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Description 1
Shows the input frequency deviation in Hertz.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Description 2
Displays the input frequency deviation in Hertz. Threshold write returns as unsuccessful if one of the breaker threshold groups does not meet conditions. In this case, read the thresholds to know which threshold group's write condition is not met. Threshold needs to be enabled to read value
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Netdisco MIB archive copies
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: mandatory.
Names: pmmInputFrequencyDeviation
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"pmmInputFrequencyDeviation",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"freqDeviationOff",
"(",
"1",
")",
",",
"freqDeviationPointTwo",
"(",
"2",
")",
",",
"freqDeviationPointFive",
"(",
"3",
")",
",",
"freqDeviationOne",
"(",
"4",
")",
",",
"freqDeviationOnePointFive",
"(",
"5",
")",
",",
"freqDeviationTwo",
"(",
"6",
")",
",",
"freqDeviationThree",
"(",
"7",
")",
",",
"freqDeviationFour",
"(",
"8",
")",
",",
"freqDeviationFive",
"(",
"9",
")",
",",
"freqDeviationNine",
"(",
"10",
")",
"}",
"ACCESS",
"read-write",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"Shows the input frequency deviation in Hertz.\"",
"::=",
"{",
"pmmInputEntry",
"10",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"freqDeviationOff",
1
],
[
"freqDeviationPointTwo",
2
],
[
"freqDeviationPointFive",
3
],
[
"freqDeviationOne",
4
],
[
"freqDeviationOnePointFive",
5
],
[
"freqDeviationTwo",
6
],
[
"freqDeviationThree",
7
],
[
"freqDeviationFour",
8
],
[
"freqDeviationFive",
9
],
[
"freqDeviationNine",
10
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"Shows the input frequency deviation in Hertz."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: PowerNet-MIB
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises', 'IpAddress', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Related source files and packages:
Status in source: mandatory.
Names: pmmInputFrequencyDeviation
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"pmmInputFrequencyDeviation",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"freqDeviationOff",
"(",
"1",
")",
",",
"freqDeviationPointTwo",
"(",
"2",
")",
",",
"freqDeviationPointFive",
"(",
"3",
")",
",",
"freqDeviationOne",
"(",
"4",
")",
",",
"freqDeviationOnePointFive",
"(",
"5",
")",
",",
"freqDeviationTwo",
"(",
"6",
")",
",",
"freqDeviationThree",
"(",
"7",
")",
",",
"freqDeviationFour",
"(",
"8",
")",
",",
"freqDeviationFive",
"(",
"9",
")",
",",
"freqDeviationNine",
"(",
"10",
")",
"}",
"ACCESS",
"read-write",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"Displays the input frequency deviation in Hertz. Threshold write returns as unsuccessful if one of the breaker threshold groups does not meet conditions. In this case, read the thresholds to know which threshold group's write condition is not met. Threshold needs to be enabled to read value\"",
"::=",
"{",
"pmmInputEntry",
"10",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"freqDeviationOff",
1
],
[
"freqDeviationPointTwo",
2
],
[
"freqDeviationPointFive",
3
],
[
"freqDeviationOne",
4
],
[
"freqDeviationOnePointFive",
5
],
[
"freqDeviationTwo",
6
],
[
"freqDeviationThree",
7
],
[
"freqDeviationFour",
8
],
[
"freqDeviationFive",
9
],
[
"freqDeviationNine",
10
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"Displays the input frequency deviation in Hertz. Threshold write returns as unsuccessful if one of the breaker threshold groups does not meet conditions. In this case, read the thresholds to know which threshold group's write condition is not met. Threshold needs to be enabled to read value"
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: PowerNet-MIB
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises', 'IpAddress', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Related source files and packages:
Vendor MIB copy from the Netdisco archive.
Module: PowerNet-MIB
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises', 'IpAddress', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Related source files and packages:
Registration