Description 1
Indicates the total power factor. A value of 100 representing a unity power factor (1.00). Specified in hundredths.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.318.1.1.28.3.1.2.1.5
Indicates the total power factor. A value of 100 representing a unity power factor (1.00). Specified in hundredths.
Identification
{1 3 6 1 4 1 318 1 1 28 3 1 2 1 5}
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.
In PowerNet-MIB, the row index pmmInputMeterIndex is declared as INTEGER. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.318.1.1.28.3.1.2.1.5.<pmmInputMeterIndex>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.318.1.1.28.3.1.2.1.5
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 2 distinct definitions; some records may not include a definition.
pmmInputTotalPowerFactor OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total power factor. A value of 100 representing
a unity power factor (1.00). Specified in hundredths."
::= { pmmInputEntry 5 }pmmInputTotalPowerFactor OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total power factor. A value of 100 representing
a unity power factor (1.00). Specified in hundredths.
Returns -255 if unsupported"
::= { pmmInputEntry 5 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Description 1
Indicates the total power factor. A value of 100 representing a unity power factor (1.00). Specified in hundredths.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Description 2
Indicates the total power factor. A value of 100 representing a unity power factor (1.00). Specified in hundredths. Returns -255 if unsupported
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Netdisco MIB archive copies
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: mandatory.
Names: pmmInputTotalPowerFactor
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"pmmInputTotalPowerFactor",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"ACCESS",
"read-only",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"Indicates the total power factor. A value of 100 representing a unity power factor (1.00). Specified in hundredths.\"",
"::=",
"{",
"pmmInputEntry",
"5",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"Indicates the total power factor. A value of 100 representing a unity power factor (1.00). Specified in hundredths."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: PowerNet-MIB
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises', 'IpAddress', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Related source files and packages:
Status in source: mandatory.
Names: pmmInputTotalPowerFactor
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"pmmInputTotalPowerFactor",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"ACCESS",
"read-only",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"Indicates the total power factor. A value of 100 representing a unity power factor (1.00). Specified in hundredths. Returns -255 if unsupported\"",
"::=",
"{",
"pmmInputEntry",
"5",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"Indicates the total power factor. A value of 100 representing a unity power factor (1.00). Specified in hundredths. Returns -255 if unsupported"
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: PowerNet-MIB
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises', 'IpAddress', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Related source files and packages:
Vendor MIB copy from the Netdisco archive.
Module: PowerNet-MIB
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises', 'IpAddress', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Related source files and packages:
Registration