Getting this OID will return commandPendingMasterTrueVM (1)
if the MasterSwitch VM has a pending command on any of its
outlets.
commandPendingMasterFalseVM (2) will be returned if there are
no pending commands.
Parsed from file powernet.mib.txt
Company: None
Module: PowerNet-MIB
Getting this OID will return commandPendingMasterTrueVM (1)
if the MasterSwitch VM has a pending command on any of its
outlets.
commandPendingMasterFalseVM (2) will be returned if there are
no pending commands.
Parsed from file PowerNet-MIB.mib
Module: PowerNet-MIB
sPDUMasterStatusVMCommandPending OBJECT-TYPE SYNTAX INTEGER { commandPendingMasterTrueVM (1), commandPendingMasterFalseVM (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Getting this OID will return commandPendingMasterTrueVM (1) if the MasterSwitch VM has a pending command on any of its outlets. commandPendingMasterFalseVM (2) will be returned if there are no pending commands." ::= { sPDUMasterStatusVMEntry 3 }
Vendor: American Power Conversion Corp.
Module: PowerNet-MIB
[Automatically extracted from oidview.com]
sPDUMasterStatusVMCommandPending OBJECT-TYPE SYNTAX INTEGER { commandPendingMasterTrueVM (1), commandPendingMasterFalseVM (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Getting this OID will return commandPendingMasterTrueVM (1) if the MasterSwitch VM has a pending command on any of its outlets. commandPendingMasterFalseVM (2) will be returned if there are no pending commands." ::= { sPDUMasterStatusVMEntry 3 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.318.1.1.5.4.2.1.1 | sPDUMasterStatusVMIndex | 0 | 0 | The index to the MasterSwitch VM entry. |
1.3.6.1.4.1.318.1.1.5.4.2.1.2 | sPDUMasterStatusVMName | 0 | 0 | The name of the MasterSwitch VM. Maximum size is 23 characters. |
1.3.6.1.4.1.318.1.1.5.4.2.1.4 | sPDUMasterStatusVMOverloadCondition | 0 | 0 | Getting this OID will return overloadConditionTrueVM (1) if the sPDUMasterConfigVMHighLoadWarningThreshold OID is violated. overlo… |
1.3.6.1.4.1.318.1.1.5.4.2.1.5 | sPDUMasterStatusVMLowLoadCondition | 0 | 0 | Getting this OID will return lowLoadConditionTrueVM (1) if the sPDUMasterConfigVMLowLoadWarningThreshold OID is violated. lowLoadC… |
1.3.6.1.4.1.318.1.1.5.4.2.1.6 | sPDUMasterStatusVMCurrentLoad | 0 | 0 | Getting this OID will return the total amount of power being consumed by the load. It is represented as a percentage of full load. |
1.3.6.1.4.1.318.1.1.5.4.2.1.7 | sPDUMasterStatusVMMaxLoad | 0 | 0 | Getting this OID will return the total amount of power that this MasterSwitch VM can provide. It is represented in Amps. |
1.3.6.1.4.1.318.1.1.5.4.2.1.8 | sPDUMasterStatusVMOutletCount | 0 | 0 | Getting this OID will return the number of controllable outlets for this MasterSwitch VM. |
1.3.6.1.4.1.318.1.1.5.4.2.1.9 | sPDUMasterStatusVMRebootDuration | 0 | 0 | Getting this OID will return the largest sPDUOutletConfigVMRebootDuration OID time for this MasterSwitch VM. |