Reference record for OID 1.3.6.1.4.1.318.1.1.9.2.1.1



parent
1.3.6.1.4.1.318.1.1.9.2.1 (dcmim2ControlSystem)
node code
1
node name
dcmim2ControlRunFunctBatteryTest
dot oid
1.3.6.1.4.1.318.1.1.9.2.1.1
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) apc(318) products(1) hardware(1) dc2(9) dcmim2Control(2) dcmim2ControlSystem(1) dcmim2ControlRunFunctBatteryTest(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) apc(318) products(1) hardware(1) dc2(9) dcmim2Control(2) dcmim2ControlSystem(1) dcmim2ControlRunFunctBatteryTest(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) apc(318) products(1) hardware(1) dc2(9) dcmim2Control(2) dcmim2ControlSystem(1) dcmim2ControlRunFunctBatteryTest(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) apc(318) products(1) hardware(1) dc2(9) dcmim2Control(2) dcmim2ControlSystem(1) dcmim2ControlRunFunctBatteryTest(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) apc(318) products(1) hardware(1) dc2(9) dcmim2Control(2) dcmim2ControlSystem(1) dcmim2ControlRunFunctBatteryTest(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) apc(318) products(1) hardware(1) dc2(9) dcmim2Control(2) dcmim2ControlSystem(1) dcmim2ControlRunFunctBatteryTest(1)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/apc/products/hardware/dc2/dcmim2Control/dcmim2ControlSystem/dcmim2ControlRunFunctBatteryTest
  • /iso/identified-organization/dod/internet/private/enterprises/apc/products/hardware/dc2/dcmim2Control/dcmim2ControlSystem/dcmim2ControlRunFunctBatteryTest
  • /iso/org/dod/internet/private/enterprise/apc/products/hardware/dc2/dcmim2Control/dcmim2ControlSystem/dcmim2ControlRunFunctBatteryTest
  • /iso/org/dod/internet/private/enterprises/apc/products/hardware/dc2/dcmim2Control/dcmim2ControlSystem/dcmim2ControlRunFunctBatteryTest
  • /iso/iso-identified-organization/dod/internet/private/enterprise/apc/products/hardware/dc2/dcmim2Control/dcmim2ControlSystem/dcmim2ControlRunFunctBatteryTest
  • /iso/iso-identified-organization/dod/internet/private/enterprises/apc/products/hardware/dc2/dcmim2Control/dcmim2ControlSystem/dcmim2ControlRunFunctBatteryTest
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/318/1/1/9/2/1/1

    Description by mibdepot

    Getting this OID will return the battery functional test state. If
    the test is off, the battTestOff (1) value will be returned.
    If the test is on, the battTestOn (2) value will be
    returned.

    Setting this OID to battTestOff (1) will turn the battery functional test off.
    Setting this OID to battTestOn (2) will turn the battery functional test on.

    Parsed from file powernet.mib.txt
    Company: None
    Module: PowerNet-MIB

    Description by circitor

    Getting this OID will return the battery functional test state. If
    the test is off, the battTestOff (1) value will be returned.
    If the test is on, the battTestOn (2) value will be
    returned.

    Setting this OID to battTestOff (1) will turn the battery functional test off.
    Setting this OID to battTestOn (2) will turn the battery functional test on.

    Parsed from file PowerNet-MIB.mib
    Module: PowerNet-MIB

    Information by mibdepot

    dcmim2ControlRunFunctBatteryTest OBJECT-TYPE SYNTAX INTEGER { battTestOff (1), battTestOn (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Getting this OID will return the battery functional test state. If the test is off, the battTestOff (1) value will be returned. If the test is on, the battTestOn (2) value will be returned. Setting this OID to battTestOff (1) will turn the battery functional test off. Setting this OID to battTestOn (2) will turn the battery functional test on." ::= { dcmim2ControlSystem 1 }

    Information by oid_info

    Vendor: American Power Conversion Corp.
    Module: PowerNet-MIB

    [Automatically extracted from oidview.com]

    Information by circitor

    dcmim2ControlRunFunctBatteryTest OBJECT-TYPE SYNTAX INTEGER { battTestOff (1), battTestOn (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Getting this OID will return the battery functional test state. If the test is off, the battTestOff (1) value will be returned. If the test is on, the battTestOn (2) value will be returned. Setting this OID to battTestOff (1) will turn the battery functional test off. Setting this OID to battTestOn (2) will turn the battery functional test on." ::= { dcmim2ControlSystem 1 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.318)

    Yoest Peter C.

    Children (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.318.1.1.9.2.1.1.0 dcmim2ControlRunFunctBatteryTest 0 0 None

    Brothers (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.318.1.1.9.2.1.2 dcmim2ControlRunCapacityBatteryTest 1 1 Getting this OID will return the battery capacity test state. If
    the test is off, the battTestOff (1) value will be returned.
    If …