Reference record for OID 1.3.6.1.4.1.3184.1.1.1.3.3.7



parent
1.3.6.1.4.1.3184.1.1.1.3.3 (FalconInput3)
node code
7
node name
FalconInput3HighLimit2
dot oid
1.3.6.1.4.1.3184.1.1.1.3.3.7
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) RLE(3184) products(1) Falcon(1) FalconMIB(1) FalconInputs(3) FalconInput3(3) FalconInput3HighLimit2(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) RLE(3184) products(1) Falcon(1) FalconMIB(1) FalconInputs(3) FalconInput3(3) FalconInput3HighLimit2(7)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) RLE(3184) products(1) Falcon(1) FalconMIB(1) FalconInputs(3) FalconInput3(3) FalconInput3HighLimit2(7)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) RLE(3184) products(1) Falcon(1) FalconMIB(1) FalconInputs(3) FalconInput3(3) FalconInput3HighLimit2(7)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) RLE(3184) products(1) Falcon(1) FalconMIB(1) FalconInputs(3) FalconInput3(3) FalconInput3HighLimit2(7)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) RLE(3184) products(1) Falcon(1) FalconMIB(1) FalconInputs(3) FalconInput3(3) FalconInput3HighLimit2(7)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/RLE/products/Falcon/FalconMIB/FalconInputs/FalconInput3/FalconInput3HighLimit2
  • /iso/identified-organization/dod/internet/private/enterprises/RLE/products/Falcon/FalconMIB/FalconInputs/FalconInput3/FalconInput3HighLimit2
  • /iso/org/dod/internet/private/enterprise/RLE/products/Falcon/FalconMIB/FalconInputs/FalconInput3/FalconInput3HighLimit2
  • /iso/org/dod/internet/private/enterprises/RLE/products/Falcon/FalconMIB/FalconInputs/FalconInput3/FalconInput3HighLimit2
  • /iso/iso-identified-organization/dod/internet/private/enterprise/RLE/products/Falcon/FalconMIB/FalconInputs/FalconInput3/FalconInput3HighLimit2
  • /iso/iso-identified-organization/dod/internet/private/enterprises/RLE/products/Falcon/FalconMIB/FalconInputs/FalconInput3/FalconInput3HighLimit2
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/3184/1/1/1/3/3/7

    Description by mibdepot

    When input 3 reaches or exceeds this value a trap will
    be generated signifying a high alarm condition at
    sensor 3.
    The HighLimit variable is stored in non-volatile memory.

    Parsed from file Falconmib.txt
    Company: None
    Module: RLE-FALCON-MIB

    Description by circitor

    When input 3 reaches or exceeds this value a trap will
    be generated signifying a high alarm condition at
    sensor 3.
    The HighLimit variable is stored in non-volatile memory.

    Parsed from file RLE-FALCON-MIB.mib
    Module: RLE-FALCON-MIB

    Information by oid_info

    Vendor: Raymond and Lae Engineering, Inc.
    Module: RLE-FALCON-MIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    FalconInput3HighLimit2 OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 3 reaches or exceeds this value a trap will be generated signifying a high alarm condition at sensor 3. The HighLimit variable is stored in non-volatile memory." ::= { FalconInput3 7 }

    Information by circitor

    falconInput3HighLimit2 OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 3 reaches or exceeds this value a trap will be generated signifying a high alarm condition at sensor 3. The HighLimit variable is stored in non-volatile memory." ::= { falconInput3 7 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.3184)

    Raymond Donald

    Children (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.3184.1.1.1.3.3.7.0 0 0 0 FalconInput3HighLimit2

    Brothers (12)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.3184.1.1.1.3.3.1 FalconInput3State 1 1 The state of use of Input Number 3. When a sensor is
    connected to Input 3 set State to installed(2) to
    indicate that the value of…
    1.3.6.1.4.1.3184.1.1.1.3.3.2 FalconInput3Reading 1 1 The reading for sensor 3.
    If the input is digital, the reading will be 1 (active) or
    0 (inactive)
    1.3.6.1.4.1.3184.1.1.1.3.3.3 FalconInput3Gain 1 1 A correction gain associated with the sensor variable.
    The value of gain is multiplied by the value from
    Input Sensor Number 3 to…
    1.3.6.1.4.1.3184.1.1.1.3.3.4 FalconInput3Offset 1 1 A correction Offset associated with the sensor variable.
    The value of Offset is added to the value from
    Input Sensor Number 3 to …
    1.3.6.1.4.1.3184.1.1.1.3.3.5 FalconInput3Label 1 1 A user-defined text string associated with Input Number 3.
    The text string is stored in non-volatile memory.
    1.3.6.1.4.1.3184.1.1.1.3.3.6 FalconInput3UOM 1 1 A user-defined text string associated with Input Number 3.
    The text string is stored in non-volatile memory.
    1.3.6.1.4.1.3184.1.1.1.3.3.8 FalconInput3HighLimit 1 1 When input 3 reaches or exceeds this value a trap will
    be generated signifying a high alarm condition at
    sensor 3.
    The HighLimit v…
    1.3.6.1.4.1.3184.1.1.1.3.3.9 FalconInput3LowLimit 1 1 When input 3 reaches or goes below this value a trap will
    be generated signifying a low alarm condition at sensor 3.
    The LowLimit…
    1.3.6.1.4.1.3184.1.1.1.3.3.10 FalconInput3LowLimit2 1 1 When input 3 reaches or goes below this value a trap will
    be generated signifying a low alarm condition at sensor 3.
    The LowLimit…
    1.3.6.1.4.1.3184.1.1.1.3.3.11 FalconInput3RlyControl 1 1 The control of the output relays. This is a binary
    setting with each bit representing an alarm state.
    To set K1 on a high alarm, …
    1.3.6.1.4.1.3184.1.1.1.3.3.12 FalconInput3Delay 1 1 The number of seconds an alarm for this input must
    be present before annunication. The range of this
    setting is 0..600.
    This varia…
    1.3.6.1.4.1.3184.1.1.1.3.3.13 FalconInput3Hysteresis 1 1 The value of alarm hysteresis for this input.
    The input reading must decrease or increase by this
    value before the alarm will cle…