Reference record for OID 1.3.6.1.4.1.36673.100.1.3.1.108

Parent
1.3.6.1.4.1.36673.100.1.3.1 (cmmAlarmMibNotifications)
Node code
108
Node name
cmmSysPSUOutputCurrentLowAlert
Numeric OID
1.3.6.1.4.1.36673.100.1.3.1.108
URN notation
urn:oid:1.3.6.1.4.1.36673.100.1.3.1.108
ASN.1 notation

{1 3 6 1 4 1 36673 100 1 3 1 108}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) ipi(36673) cmm(100) cmmChassisObject(1) cmmAlarmObjects(3) cmmAlarmMibNotifications(1) cmmSysPSUOutputCurrentLowAlert(108)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) ipi(36673) cmm(100) cmmChassisObject(1) cmmAlarmObjects(3) cmmAlarmMibNotifications(1) cmmSysPSUOutputCurrentLowAlert(108)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) ipi(36673) cmm(100) cmmChassisObject(1) cmmAlarmObjects(3) cmmAlarmMibNotifications(1) cmmSysPSUOutputCurrentLowAlert(108)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) ipi(36673) cmm(100) cmmChassisObject(1) cmmAlarmObjects(3) cmmAlarmMibNotifications(1) cmmSysPSUOutputCurrentLowAlert(108)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) ipi(36673) cmm(100) cmmChassisObject(1) cmmAlarmObjects(3) cmmAlarmMibNotifications(1) cmmSysPSUOutputCurrentLowAlert(108)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) ipi(36673) cmm(100) cmmChassisObject(1) cmmAlarmObjects(3) cmmAlarmMibNotifications(1) cmmSysPSUOutputCurrentLowAlert(108)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) ipi(36673) cmm(100) cmmChassisObject(1) cmmAlarmObjects(3) cmmAlarmMibNotifications(1) cmmSysPSUOutputCurrentLowAlert(108)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) ipi(36673) cmm(100) cmmChassisObject(1) cmmAlarmObjects(3) cmmAlarmMibNotifications(1) cmmSysPSUOutputCurrentLowAlert(108)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) ipi(36673) cmm(100) cmmChassisObject(1) cmmAlarmObjects(3) cmmAlarmMibNotifications(1) cmmSysPSUOutputCurrentLowAlert(108)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) ipi(36673) cmm(100) cmmChassisObject(1) cmmAlarmObjects(3) cmmAlarmMibNotifications(1) cmmSysPSUOutputCurrentLowAlert(108)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) ipi(36673) cmm(100) cmmChassisObject(1) cmmAlarmObjects(3) cmmAlarmMibNotifications(1) cmmSysPSUOutputCurrentLowAlert(108)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) ipi(36673) cmm(100) cmmChassisObject(1) cmmAlarmObjects(3) cmmAlarmMibNotifications(1) cmmSysPSUOutputCurrentLowAlert(108)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) ipi(36673) cmm(100) cmmChassisObject(1) cmmAlarmObjects(3) cmmAlarmMibNotifications(1) cmmSysPSUOutputCurrentLowAlert(108)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) ipi(36673) cmm(100) cmmChassisObject(1) cmmAlarmObjects(3) cmmAlarmMibNotifications(1) cmmSysPSUOutputCurrentLowAlert(108)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) ipi(36673) cmm(100) cmmChassisObject(1) cmmAlarmObjects(3) cmmAlarmMibNotifications(1) cmmSysPSUOutputCurrentLowAlert(108)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) ipi(36673) cmm(100) cmmChassisObject(1) cmmAlarmObjects(3) cmmAlarmMibNotifications(1) cmmSysPSUOutputCurrentLowAlert(108)}
OID-IRI notation
  • /1/3/6/1/4/1/36673/100/1/3/1/108
  • /ISO/Identified-Organization/6/1/4/1/36673/100/1/3/1/108
  • /ISO/3/6/1/4/1/36673/100/1/3/1/108
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/36673/cmm/cmmChassisObject/cmmAlarmObjects/cmmAlarmMibNotifications/cmmSysPSUOutputCurrentLowAlert
  • /iso/identified-organization/dod/internet/private/enterprise/ipi/cmm/cmmChassisObject/cmmAlarmObjects/cmmAlarmMibNotifications/cmmSysPSUOutputCurrentLowAlert
  • /iso/identified-organization/dod/internet/private/enterprises/36673/cmm/cmmChassisObject/cmmAlarmObjects/cmmAlarmMibNotifications/cmmSysPSUOutputCurrentLowAlert
  • /iso/identified-organization/dod/internet/private/enterprises/ipi/cmm/cmmChassisObject/cmmAlarmObjects/cmmAlarmMibNotifications/cmmSysPSUOutputCurrentLowAlert
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/36673/cmm/cmmChassisObject/cmmAlarmObjects/cmmAlarmMibNotifications/cmmSysPSUOutputCurrentLowAlert
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/ipi/cmm/cmmChassisObject/cmmAlarmObjects/cmmAlarmMibNotifications/cmmSysPSUOutputCurrentLowAlert
  • /iso/identified-organization/dod/internet/private/vendor-objects/36673/cmm/cmmChassisObject/cmmAlarmObjects/cmmAlarmMibNotifications/cmmSysPSUOutputCurrentLowAlert
  • /iso/identified-organization/dod/internet/private/vendor-objects/ipi/cmm/cmmChassisObject/cmmAlarmObjects/cmmAlarmMibNotifications/cmmSysPSUOutputCurrentLowAlert
  • /iso/org/dod/internet/private/enterprise/36673/cmm/cmmChassisObject/cmmAlarmObjects/cmmAlarmMibNotifications/cmmSysPSUOutputCurrentLowAlert
  • /iso/org/dod/internet/private/enterprise/ipi/cmm/cmmChassisObject/cmmAlarmObjects/cmmAlarmMibNotifications/cmmSysPSUOutputCurrentLowAlert
  • /iso/org/dod/internet/private/enterprises/36673/cmm/cmmChassisObject/cmmAlarmObjects/cmmAlarmMibNotifications/cmmSysPSUOutputCurrentLowAlert
  • /iso/org/dod/internet/private/enterprises/ipi/cmm/cmmChassisObject/cmmAlarmObjects/cmmAlarmMibNotifications/cmmSysPSUOutputCurrentLowAlert
  • /iso/org/dod/internet/private/ldap-enterprise/36673/cmm/cmmChassisObject/cmmAlarmObjects/cmmAlarmMibNotifications/cmmSysPSUOutputCurrentLowAlert
  • /iso/org/dod/internet/private/ldap-enterprise/ipi/cmm/cmmChassisObject/cmmAlarmObjects/cmmAlarmMibNotifications/cmmSysPSUOutputCurrentLowAlert
  • /iso/org/dod/internet/private/vendor-objects/36673/cmm/cmmChassisObject/cmmAlarmObjects/cmmAlarmMibNotifications/cmmSysPSUOutputCurrentLowAlert
  • /iso/org/dod/internet/private/vendor-objects/ipi/cmm/cmmChassisObject/cmmAlarmObjects/cmmAlarmMibNotifications/cmmSysPSUOutputCurrentLowAlert
  • Additional combinations skipped.

Descriptions

cmmSysPSUOutputCurrentLowAlert — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Set when PSU output current reached low alert threshold value.

Source records

cmmSysPSUOutputCurrentLowAlert

Status in source: current.

Names: cmmSysPSUOutputCurrentLowAlert

Technical details
{
  "smi_kind": "NOTIFICATION-TYPE",
  "definition": [
    "cmmSysPSUOutputCurrentLowAlert",
    "NOTIFICATION-TYPE",
    "OBJECTS",
    "{",
    "cmmStackUnitIndex",
    ",",
    "cmmSysPSUIndex",
    ",",
    "cmmSysOutputCurrent",
    ",",
    "cmmSysOutputCurrentAlertThresholdMin",
    ",",
    "cmmSysOutputCurrentAlertThresholdMax",
    "}",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Set when PSU output current reached low alert threshold value.\"",
    "::=",
    "{",
    "cmmAlarmMibNotifications",
    "108",
    "}"
  ],
  "syntax_tree": [
    [
      "Objects",
      [
        "cmmStackUnitIndex",
        "cmmSysPSUIndex",
        "cmmSysOutputCurrent",
        "cmmSysOutputCurrentAlertThresholdMin",
        "cmmSysOutputCurrentAlertThresholdMax"
      ]
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Set when PSU output current reached low alert threshold value."
    ],
    null
  ]
}
  • Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community) · Publisher's source file: IPI-CMM-CHASSIS-MIB

    Vendor MIB copy from the LibreNMS archive.

    Module: IPI-CMM-CHASSIS-MIB

    Published definition
    cmmSysPSUOutputCurrentLowAlert  NOTIFICATION-TYPE
            OBJECTS      {
                          cmmStackUnitIndex,
                          cmmSysPSUIndex,
                          cmmSysOutputCurrent,
                          cmmSysOutputCurrentAlertThresholdMin,
                          cmmSysOutputCurrentAlertThresholdMax
                         }
            STATUS       current
            DESCRIPTION
                "Set when PSU output current reached low alert threshold value."
            ::= { cmmAlarmMibNotifications 108 }
    Module imports
    {'SNMPv2-TC': ['DateAndTime', 'DisplayString', 'MacAddress', 'RowStatus', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'MODULE-IDENTITY', 'Gauge32', 'Counter32', 'Unsigned32', 'TimeTicks', 'NOTIFICATION-TYPE', 'enterprises', 'OBJECT-IDENTITY'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'IPI-MODULE-MIB': ['ipi']}

    Related source files and packages:


    Source location: IPI-CMM-CHASSIS-MIB::cmmSysPSUOutputCurrentLowAlert.
    Source version and references

    Same file in Observium Community.

    Downloaded: 2026-10-24T02:14:15.518300+00:00.

  • Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive.

    Module: IPI-CMM-CHASSIS-MIB

    Published definition
    cmmSysPSUOutputCurrentLowAlert  NOTIFICATION-TYPE
            OBJECTS      {
                          cmmStackUnitIndex,
                          cmmSysPSUIndex,
                          cmmSysOutputCurrent,
                          cmmSysOutputCurrentAlertThresholdMin,
                          cmmSysOutputCurrentAlertThresholdMax
                         }
            STATUS       current
            DESCRIPTION
                "Set when PSU output current reached low alert threshold value."
            ::= { cmmAlarmMibNotifications 108 }
    Module imports
    {'SNMPv2-TC': ['DateAndTime', 'DisplayString', 'MacAddress', 'RowStatus', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'MODULE-IDENTITY', 'Gauge32', 'Counter32', 'Unsigned32', 'TimeTicks', 'NOTIFICATION-TYPE', 'enterprises', 'OBJECT-IDENTITY'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'IPI-MODULE-MIB': ['ipi']}

    Related source files and packages:


    Source location: IPI-CMM-CHASSIS-MIB::cmmSysPSUOutputCurrentLowAlert.
    Source version and references

    Downloaded: 2026-10-24T02:14:23.853191+00:00.

Current Registration Authority (inferred from ancestor 1.3.6.1.4.1.36673)

Vishwas Manral

Siblings (128)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.36673.100.1.3.1.1 cmmCpuLoad15MinAlert00
1.3.6.1.4.1.36673.100.1.3.1.2 cmmCpuLoad5MinAlert00
1.3.6.1.4.1.36673.100.1.3.1.3 cmmCpuLoad1MinCritical00
1.3.6.1.4.1.36673.100.1.3.1.4 cmmCpuLoad1MinAlert00
1.3.6.1.4.1.36673.100.1.3.1.5 cmmCpuLoad1MinCriticalRecovery00
1.3.6.1.4.1.36673.100.1.3.1.6 cmmCpuLoad15MinAlertRecovery00
1.3.6.1.4.1.36673.100.1.3.1.7 cmmCpuLoad5MinAlertRecovery00
1.3.6.1.4.1.36673.100.1.3.1.8 cmmCpuLoad1MinAlertRecovery00
1.3.6.1.4.1.36673.100.1.3.1.9 cmmCpuCoreUtilHighCritical00
1.3.6.1.4.1.36673.100.1.3.1.10 cmmCpuCoreUtilHighAlert00
1.3.6.1.4.1.36673.100.1.3.1.11 cmmCpuCoreUtilHighCriticalRecovery00
1.3.6.1.4.1.36673.100.1.3.1.12 cmmCpuCoreUtilHighAlertRecovery00
1.3.6.1.4.1.36673.100.1.3.1.21 cmmRamUsageRisingCritical00
1.3.6.1.4.1.36673.100.1.3.1.22 cmmRamUsageRisingAlert00
1.3.6.1.4.1.36673.100.1.3.1.23 cmmRamUsageCriticalRecovery00
1.3.6.1.4.1.36673.100.1.3.1.24 cmmRamUsageAlertRecovery00
1.3.6.1.4.1.36673.100.1.3.1.25 cmmHardDiskUsageRisingCritical00
1.3.6.1.4.1.36673.100.1.3.1.26 cmmHardDiskUsageRisingAlert00
1.3.6.1.4.1.36673.100.1.3.1.27 cmmHardDiskUsageCriticalRecovery00
1.3.6.1.4.1.36673.100.1.3.1.28 cmmHardDiskUsageAlertRecovery00
1.3.6.1.4.1.36673.100.1.3.1.29 cmmSysHardDiskRemainLifeRisingAlert00
1.3.6.1.4.1.36673.100.1.3.1.30 cmmSysHardDiskRemainLifeRisingCritical00
1.3.6.1.4.1.36673.100.1.3.1.31 cmmSysHardDiskAvailableReservedSpaceAlert00
1.3.6.1.4.1.36673.100.1.3.1.32 cmmSysHardDiskAvailableReservedSpaceCritical00
1.3.6.1.4.1.36673.100.1.3.1.33 cmmSysHardDiskReallocSectorsCountAlert00
1.3.6.1.4.1.36673.100.1.3.1.34 cmmSysHardDiskUncorrectableSectorCountCritical00
1.3.6.1.4.1.36673.100.1.3.1.35 cmmSysHardDiskActivityMonitoringReadAlert00
1.3.6.1.4.1.36673.100.1.3.1.36 cmmSysHardDiskActivityMonitoringReadRecovery00
1.3.6.1.4.1.36673.100.1.3.1.37 cmmSysHardDiskActivityMonitoringWriteAlert00
1.3.6.1.4.1.36673.100.1.3.1.38 cmmSysHardDiskActivityMonitoringWriteRecovery00
1.3.6.1.4.1.36673.100.1.3.1.39 cmmSysHardDiskStorageStatusNotification00
1.3.6.1.4.1.36673.100.1.3.1.41 cmmTemperatureLowEmergency00
1.3.6.1.4.1.36673.100.1.3.1.42 cmmTemperatureHighEmergency00
1.3.6.1.4.1.36673.100.1.3.1.43 cmmTemperatureLowCritical00
1.3.6.1.4.1.36673.100.1.3.1.44 cmmTemperatureHighCritical00
1.3.6.1.4.1.36673.100.1.3.1.45 cmmTemperatureLowAlert00
1.3.6.1.4.1.36673.100.1.3.1.46 cmmTemperatureHighAlert00
1.3.6.1.4.1.36673.100.1.3.1.47 cmmTemperatureHighCriticalRecovery00
1.3.6.1.4.1.36673.100.1.3.1.48 cmmTemperatureLowCriticalRecovery00
1.3.6.1.4.1.36673.100.1.3.1.49 cmmTemperatureHighAlertRecovery00
1.3.6.1.4.1.36673.100.1.3.1.50 cmmTemperatureLowAlertRecovery00
1.3.6.1.4.1.36673.100.1.3.1.61 cmmPsuInsertedNotify00
1.3.6.1.4.1.36673.100.1.3.1.62 cmmPsuRemovedCritical00
1.3.6.1.4.1.36673.100.1.3.1.63 cmmPsuAcFailedCritical00
1.3.6.1.4.1.36673.100.1.3.1.64 cmmPsuAcRecover00
1.3.6.1.4.1.36673.100.1.3.1.65 cmmPsu12vPgFailedCritical00
1.3.6.1.4.1.36673.100.1.3.1.66 cmmPsu12vPgRecover00
1.3.6.1.4.1.36673.100.1.3.1.67 cmmSysPSUInputVoltageHighAlert00
1.3.6.1.4.1.36673.100.1.3.1.68 cmmSysPSUInputVoltageLowAlert00
1.3.6.1.4.1.36673.100.1.3.1.69 cmmSysPSUInputVoltageHighCritical00