1.Index referring to the equipment table (Shelf, Slot) (9 bits)
2. Index containing MPHY port number in card.
For OC3 trib 0-3
For TC&ATM If's we also have:
· SAR if. = SAR_FIFO_IF (FE)
· APS FIFO = ASP_FIFO_IF (FF)
Note that these new interfaces have no 'low layers' bellow, i.e. there are no SONET layers on these virtual supports (6 bits).
3. Index containing sub-port number, e.g., 0-3 OC12's in OC48 frame (6 bits).
4.
(2^6-1)-Null (all bits are 1) reserved for NULL interface, NullVCPeerID, etc.
1-OTS'SRC Optical Transmission Section Source (OPA,ADOM,OMDM)
2-OTS-SNK Optical Transmission Section Sink. (OPA,ADOM,OMDM)
3-OMS-SRC Optical Multiplex Section Source (ADOM, OMDM)
4-OMS-SNK Optical Multiplex Section Sink (ADOM, OMDM)
5-OCH Optical Channel (OCM/Trib)
6-SNT-S Sonet Section (OCM/Trib)
7-SNT-L Sonet Line (OCM/Trib)
8-SNT-P Sonet Path (OCM/Trib)
9-TC&ATM C and ATM general cell layer (OCM/Trib)
10-Ethernet
11-IP
12-Synchronization
(6 bits)
5. Virtual interface represent a whole protection peer, out of which some members are working and the rest are protecting.
SAR and Egress FIFO are real interfaces (5 bits).
Parsed from file ChrComIfifTable.mib.txt
Company: chromatis
Module: ChrComIfifTable-MIB
Vendor: Chromatis Networks Inc.
Module: ChrComIfiftable-MIB
[Automatically extracted from oidview.com]
chrComIfifIndex OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "1.Index referring to the equipment table (Shelf, Slot) (9 bits) 2. Index containing MPHY port number in card. For OC3 trib 0-3 For TC&ATM If's we also have: · SAR if. = SAR_FIFO_IF (FE) · APS FIFO = ASP_FIFO_IF (FF) Note that these new interfaces have no 'low layers' bellow, i.e. there are no SONET layers on these virtual supports (6 bits). 3. Index containing sub-port number, e.g., 0-3 OC12's in OC48 frame (6 bits). 4. (2^6-1)-Null (all bits are 1) reserved for NULL interface, NullVCPeerID, etc. 1-OTS'SRC Optical Transmission Section Source (OPA,ADOM,OMDM) 2-OTS-SNK Optical Transmission Section Sink. (OPA,ADOM,OMDM) 3-OMS-SRC Optical Multiplex Section Source (ADOM, OMDM) 4-OMS-SNK Optical Multiplex Section Sink (ADOM, OMDM) 5-OCH Optical Channel (OCM/Trib) 6-SNT-S Sonet Section (OCM/Trib) 7-SNT-L Sonet Line (OCM/Trib) 8-SNT-P Sonet Path (OCM/Trib) 9-TC&ATM C and ATM general cell layer (OCM/Trib) 10-Ethernet 11-IP 12-Synchronization (6 bits) 5. Virtual interface represent a whole protection peer, out of which some members are working and the rest are protecting. SAR and Egress FIFO are real interfaces (5 bits). " ::= { chrComIfifTableEntry 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.3695.1.2.10.1.2 | chrComIfifName | 0 | 0 | String of text defining the name of the port given by the user. |
1.3.6.1.4.1.3695.1.2.10.1.3 | chrComIfifAdminStatus | 0 | 0 | The desired state of the interface. The testing(3) state indicates that no operational packets can be passed. When a managed … |
1.3.6.1.4.1.3695.1.2.10.1.4 | chrComIfifOperStatus | 0 | 0 | The down state of ifOperStatus has two meanings, depending on the value of ifAdminStatus. (1) if ifAdminStatus is not down and i… |
1.3.6.1.4.1.3695.1.2.10.1.5 | chrComIfvirtualIfIndex | 0 | 0 | This attribute is an outcome of the card/Path Protection attribute of the equipment table. The peer ID is a virtual card ID (wh… |
1.3.6.1.4.1.3695.1.2.10.1.6 | chrComIfreal1IfIndex | 0 | 0 | This field represents the first real IfIndex , if IfIndex is virtual. |
1.3.6.1.4.1.3695.1.2.10.1.7 | chrComIfreal2IfIndex | 0 | 0 | This field represents the second real IfIndex , if IfIndex is virtual. |