(Automatic Gain Control -AGC : Default)
Automatic Pump Power Control : PPC
Parsed from file ChrComIfOpticsOMS_SNK.mib.txt
Company: chromatis
Module: ChrComIfOpticsOMS-SNK-MIB
Vendor: Chromatis Networks Inc.
Module: ChrComIfOpticsOMS-SNK-MIB
[Automatically extracted from oidview.com]
chrComIfOpticsOmsSnkOPAModeOfOperation OBJECT-TYPE SYNTAX Agcppc MAX-ACCESS read-write STATUS current DESCRIPTION " (Automatic Gain Control -AGC : Default) Automatic Pump Power Control : PPC " ::= { chrComIfOpticsOMS-SNKEntry 17 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.3695.1.2.3.3.1.1 | chrComIfOpticsOmsSnkNumOfPrecedingOPAs | 0 | 0 | None |
1.3.6.1.4.1.3695.1.2.3.3.1.2 | chrComIfOpticsOmsSnkDWDMInputPower | 0 | 0 | The aggregated optical power of all the DWDM input channels (without the 1310nm channel). |
1.3.6.1.4.1.3695.1.2.3.3.1.3 | chrComIfOpticsOmsSnkOPALOOCThr | 0 | 0 | Threshold for the 'OMS-SNK DWDM Input Power', indicating Loss Of Optical DWDM Channels at the input to the Pre-OPA/in-line-OPA. |
1.3.6.1.4.1.3695.1.2.3.3.1.4 | chrComIfOpticsOmsSnkParamForOPALOOCThr | 0 | 0 | Input parameter for calculating 'OMS-SNK LOOC Threshold' (for pre-OPA/in-line-OPA only). |
1.3.6.1.4.1.3695.1.2.3.3.1.5 | chrComIfOpticsOmsSnkLOOPThr | 0 | 0 | Threshold for the 'OMS-SNK DWDM Input Power' indicating Loss Of Optical power in the DWDM band at the input to ADOM/OMDM. |
1.3.6.1.4.1.3695.1.2.3.3.1.6 | chrComIfOpticsOmsSnkReceived1310Power | 0 | 0 | The optical power monitored on 1310 Receive point. |
1.3.6.1.4.1.3695.1.2.3.3.1.7 | chrComIfOpticsOmsSnkReceivedLambdaPower | 0 | 0 | The optical power monitored on ADOM Lambda Receive point. |
1.3.6.1.4.1.3695.1.2.3.3.1.8 | chrComIfOpticsOmsSnkBackplaneAttenuatorLambda | 0 | 0 | Attenuation in dB. Zero when no backplane Attenuator exists. |
1.3.6.1.4.1.3695.1.2.3.3.1.9 | chrComIfOpticsOmsSnkBackplaneAttenuator1310 | 0 | 0 | Attenuation in dB. Zero when no backplane Attenuator exists. |
1.3.6.1.4.1.3695.1.2.3.3.1.10 | chrComIfOpticsOmsSnkParamForRxLambdaLOOCThr | 0 | 0 | Input parameter for calculating 'OMS-SNK Received lambda LOOC threshold' |
1.3.6.1.4.1.3695.1.2.3.3.1.11 | chrComIfOpticsOmsSnkRxLambdaLOOCThr | 0 | 0 | Loop Threshold of 'OMS-SNK Received lambda power'. |
1.3.6.1.4.1.3695.1.2.3.3.1.12 | chrComIfOpticsOmsSnkRx1310LOOCThr | 0 | 0 | Loop threshold of 'OMS-SNK Received 1310 Power'. |
1.3.6.1.4.1.3695.1.2.3.3.1.13 | chrComIfOpticsOmsSnkOchRRx1310LOOCThr | 0 | 0 | A duplication of the 'OCH-R Received 1310 Looc threshold'. |
1.3.6.1.4.1.3695.1.2.3.3.1.14 | chrComIfOpticsOmsSnkPreOPADWDMOutPower | 0 | 0 | Total Optical Power Monitored at the output of a Pre-OPA. |
1.3.6.1.4.1.3695.1.2.3.3.1.15 | chrComIfOpticsOmsSnkPreOPAOutLOOPThr | 0 | 0 | This is a threshold on the output power of the pre-OPA. |
1.3.6.1.4.1.3695.1.2.3.3.1.16 | chrComIfOpticsOmsSnkPreOPASafetyThr | 0 | 0 | This is a threshold on the output power of the pre-OPA. |
1.3.6.1.4.1.3695.1.2.3.3.1.18 | chrComIfOpticsOmsSnkOPAExpectedGain | 0 | 0 | Integer32, Units of 0.1 db. 0 ' 35 db (10dB) |
1.3.6.1.4.1.3695.1.2.3.3.1.19 | chrComIfOpticsOmsSnkOPAActualGain | 0 | 0 | Integer32, Units of 0.1 db. 0 ' 35 db |
1.3.6.1.4.1.3695.1.2.3.3.1.20 | chrComIfOpticsOmsSnkOPAExpectedPumpPower | 0 | 0 | The Desired EDFA pump power of pre-/in-line-OPA module. |
1.3.6.1.4.1.3695.1.2.3.3.1.21 | chrComIfOpticsOmsSnkOPAActualPumpPower | 0 | 0 | The Actual EDFA pump power of pre-/in-line-OPA module. |
1.3.6.1.4.1.3695.1.2.3.3.1.22 | chrComIfOpticsOmsSnkOPAAPSDState | 0 | 0 | Controlling the Automatic Pump Shut Down (APSD) mode. |
1.3.6.1.4.1.3695.1.2.3.3.1.23 | chrComIfOpticsOmsSnkOPAPumpRestartAction | 0 | 0 | Enables 'remote operation' which is equivalent to the restart push button of the pre-/in-line-OPA. |
1.3.6.1.4.1.3695.1.2.3.3.1.24 | chrComIfOpticsOmsSnkOPAPumpActivationStatus | 0 | 0 | Pre-/in-line-OPA Pump Laser ON/OFF Actual status. |
1.3.6.1.4.1.3695.1.2.3.3.1.25 | chrComIfOpticsOmsSnkOPAExpectedAttenuatorAttenuation | 0 | 0 | The expected Attenuation of the attenuator at the output of the OPA |
1.3.6.1.4.1.3695.1.2.3.3.1.26 | chrComIfOpticsOmsSnkOPAActualAttenuatorAttenuation | 0 | 0 | The actual Attenuation of the attenuator at the output of the OPA |
1.3.6.1.4.1.3695.1.2.3.3.1.27 | chrComIfOpticsOmsSnkOPAPumpTemperature | 0 | 0 | The temperature of the module. |
1.3.6.1.4.1.3695.1.2.3.3.1.28 | chrComIfOpticsOmsSnkOPAPumpBiasCurrent | 0 | 0 | None |
1.3.6.1.4.1.3695.1.2.3.3.1.29 | chrComIfOpticsAlarmVector | 0 | 0 | None |
1.3.6.1.4.1.3695.1.2.3.3.1.30 | chrComIfOpticsAlarmSeverityProfileIndex | 0 | 0 | None |