Vendor: Chromatis Networks Inc.
Module: ChrComIfOpticsOMS-SRC-MIB
[Automatically extracted from oidview.com]
chrComIfOpticsOMS-SRCEntry OBJECT-TYPE SYNTAX ChrComIfOpticsOMS-SRCEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { chrComIfifIndex } ::= { chrComIfOpticsOMS-SRCTable 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.3695.1.2.3.4.1.1 | chrComIfOpticsOmsSrcNumOfPrecedingOPAs | 0 | 0 | Number of OPAs prior to the respective ADOM/OMDM. |
1.3.6.1.4.1.3695.1.2.3.4.1.2 | chrComIfOpticsOmsSrcDWDMOutputPower | 0 | 0 | The optical power in the DWDM band (without the 1310nm channel) at the output of the module. |
1.3.6.1.4.1.3695.1.2.3.4.1.3 | chrComIfOpticsOmsSrcDWDMLOOPThr | 0 | 0 | This is a threshold on 'OMS-SRC DWDM output Power', indicating the existence of power in the DWDM band at the output of the mo… |
1.3.6.1.4.1.3695.1.2.3.4.1.4 | chrComIfOpticsOmsSrcDWDMSafetyThr | 0 | 0 | This is a threshold on 'OMS-SRC DWDM output Power', indicating the safety power level in the DWDM band at the output of the AD… |
1.3.6.1.4.1.3695.1.2.3.4.1.5 | chrComIfOpticsOmsSrcTx1310Power | 0 | 0 | The optical power monitored on 1310 transmit point. |
1.3.6.1.4.1.3695.1.2.3.4.1.6 | chrComIfOpticsOmsSrcTxLambdaPower | 0 | 0 | The optical power monitored on Lambda transmit point. |
1.3.6.1.4.1.3695.1.2.3.4.1.7 | chrComIfOpticsOmsSrcADOMPwrControlMode | 0 | 0 | Defines ADOM module operational mode. |
1.3.6.1.4.1.3695.1.2.3.4.1.8 | chrComIfOpticsOmsSrcExpectedAddedLambdaPower | 0 | 0 | The expected added Lambda channel power after Attenuation (reflected to module out). |
1.3.6.1.4.1.3695.1.2.3.4.1.9 | chrComIfOpticsOmsSrcActualAddedPower | 0 | 0 | Monitored added lambda channel power after Attenuation (reflected to module out). |
1.3.6.1.4.1.3695.1.2.3.4.1.10 | chrComIfOpticsOmsSrcExpectedAddedLambdaPowerOffset | 0 | 0 | The expected added to dropped lambda channel power offset. |
1.3.6.1.4.1.3695.1.2.3.4.1.11 | chrComIfOpticsOmsSrcActualAddedPowerOffset | 0 | 0 | The Actual added to dropped lambda channel power offset. |
1.3.6.1.4.1.3695.1.2.3.4.1.12 | chrComIfOpticsOmsSrcExpectedAddedChannelAttenuation | 0 | 0 | The expected Attenuation of added lambda channel |
1.3.6.1.4.1.3695.1.2.3.4.1.13 | chrComIfOpticsOmsSrcActualAddedChannelAttenuation | 0 | 0 | None |
1.3.6.1.4.1.3695.1.2.3.4.1.14 | chrComIfOpticsOmsSrcBackplaneAttenuatorLambda | 0 | 0 | Attenuation in dB. Zero when no backplane Attenuator exists. |
1.3.6.1.4.1.3695.1.2.3.4.1.15 | chrComIfOpticsOmsSrcBackplaneAttenuator1310 | 0 | 0 | Attenuation in dB. Zero when no backplane Attenuator exists. |
1.3.6.1.4.1.3695.1.2.3.4.1.16 | chrComIfOpticsOmsSrcTxLambdaLOOCThr | 0 | 0 | Looc Threshold of transmitted lambda power. |
1.3.6.1.4.1.3695.1.2.3.4.1.17 | chrComIfOpticsOmsSrcOCHSLOOCThrLambda | 0 | 0 | A duplication of the 'OCH-S Looc Threshold'. |
1.3.6.1.4.1.3695.1.2.3.4.1.18 | chrComIfOpticsOmsSrcAddedLambdaLOOCThr | 0 | 0 | Looc Threshold of added lambda. |
1.3.6.1.4.1.3695.1.2.3.4.1.19 | chrComIfOpticsOmsSrcTx1310LOOCThr | 0 | 0 | Looc Threshold of transmitted 1310. |
1.3.6.1.4.1.3695.1.2.3.4.1.20 | chrComIfOpticsOmsSrcOCHSLOOCThr1310 | 0 | 0 | A duplication of the 'OCH-S Looc Threshold'. |
1.3.6.1.4.1.3695.1.2.3.4.1.21 | chrComIfOpticsOmsSrcPostOPADWDMInputPower | 0 | 0 | The optical power in the DWDM band (without the 1310nm channel) at the input of the pre-OPA. |
1.3.6.1.4.1.3695.1.2.3.4.1.22 | chrComIfOpticsOmsSrcPostOPAInputLOOCThr | 0 | 0 | This is a threshold on 'OMS-SRC post-OPA DWDM input Power', indicating Loss Of Optical DWDM Channels at the input to the Post-O… |
1.3.6.1.4.1.3695.1.2.3.4.1.23 | chrComIfOpticsOmsSrcParamForPostOPAInputLOOCThr | 0 | 0 | Input parameter for calculating 'OMS-SRC post-OPA input LOOC threshold'. |
1.3.6.1.4.1.3695.1.2.3.4.1.24 | chrComIfOpticsOmsSrcPostOPAInputLOOPThr | 0 | 0 | This is a threshold on 'OMS-SRC post-OPA DWDM input Power', indicating Loss Of Optical DWDM power at the input to the Post-OPA. |
1.3.6.1.4.1.3695.1.2.3.4.1.25 | chrComIfOpticsOmsSrcPostOPAModeOfOperation | 0 | 0 | (Automatic Gain Control AGC ' Default) Automatic Pump Power Control ' PPC |
1.3.6.1.4.1.3695.1.2.3.4.1.26 | chrComIfOpticsOmsSrcPostOPAExpectedGain | 0 | 0 | The Desired gain of the post OPA module (input to output optical DWDM power). |
1.3.6.1.4.1.3695.1.2.3.4.1.27 | chrComIfOpticsOmsSrcPostOPAActualGain | 0 | 0 | The Actual gain of the post OPA (input to output optical DWDM power). |
1.3.6.1.4.1.3695.1.2.3.4.1.28 | chrComIfOpticsOmsSrcPostOPAExpectedPumpPower | 0 | 0 | The Desired EDFA pump power of post-OPA module. |
1.3.6.1.4.1.3695.1.2.3.4.1.29 | chrComIfOpticsOmsSrcPostOPAActualPumpPower | 0 | 0 | The Actual EDFA pump power of post-OPA module. |
1.3.6.1.4.1.3695.1.2.3.4.1.30 | chrComIfOpticsOmsSrcPostOPAAPSDState | 0 | 0 | Controlling the Automatic Pump Shut Down (APSD) mode. |
1.3.6.1.4.1.3695.1.2.3.4.1.31 | chrComIfOpticsOmsSrcPostOPAPumpRestartAction | 0 | 0 | Enables 'remote operation' which is equivalent to the restart push button of the post-OPA. |
1.3.6.1.4.1.3695.1.2.3.4.1.32 | chrComIfOpticsOmsSrcPostOPAPumpLaserActivationStatus | 0 | 0 | Post OPA Pump Laser ON/OFF Actual status. |
1.3.6.1.4.1.3695.1.2.3.4.1.33 | chrComIfOpticsOmsSrcOPAExpectedAttenuatorAttenuation | 0 | 0 | The expected Attenuation of the attenuator at the output of the OPA |
1.3.6.1.4.1.3695.1.2.3.4.1.34 | chrComIfOpticsOmsSrcOPAActualAttenuatorAttenuation | 0 | 0 | The actual Attenuation of the attenuator at the output of the OPA |
1.3.6.1.4.1.3695.1.2.3.4.1.35 | chrComIfOpticsOmsSrcPostOPAPumpTemp | 0 | 0 | The temperature of the module. |
1.3.6.1.4.1.3695.1.2.3.4.1.36 | chrComIfOpticsOmsSrcPostOPAPumpBiasCurrent | 0 | 0 | None |
1.3.6.1.4.1.3695.1.2.3.4.1.37 | chrComIfOpticsAlarmVector | 0 | 0 | None |
1.3.6.1.4.1.3695.1.2.3.4.1.38 | chrComIfOpticsAlarmSeverityProfileIndex | 0 | 0 | None |