Reference record for OID 1.3.6.1.4.1.3727.20.10.4.31


parent
1.3.6.1.4.1.3727.20.10.4 (log)
node code
31
node name
logTrapHysteresis
dot oid
1.3.6.1.4.1.3727.20.10.4.31
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) western-multiplex(3727) tsunami100-06(20) system(10) log(4) logTrapHysteresis(31)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) western-multiplex(3727) tsunami100-06(20) system(10) log(4) logTrapHysteresis(31)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) western-multiplex(3727) tsunami100-06(20) system(10) log(4) logTrapHysteresis(31)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) western-multiplex(3727) tsunami100-06(20) system(10) log(4) logTrapHysteresis(31)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) western-multiplex(3727) tsunami100-06(20) system(10) log(4) logTrapHysteresis(31)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) western-multiplex(3727) tsunami100-06(20) system(10) log(4) logTrapHysteresis(31)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/western-multiplex/tsunami100-06/system/log/logTrapHysteresis
  • /iso/identified-organization/dod/internet/private/enterprises/western-multiplex/tsunami100-06/system/log/logTrapHysteresis
  • /iso/org/dod/internet/private/enterprise/western-multiplex/tsunami100-06/system/log/logTrapHysteresis
  • /iso/org/dod/internet/private/enterprises/western-multiplex/tsunami100-06/system/log/logTrapHysteresis
  • /iso/iso-identified-organization/dod/internet/private/enterprise/western-multiplex/tsunami100-06/system/log/logTrapHysteresis
  • /iso/iso-identified-organization/dod/internet/private/enterprises/western-multiplex/tsunami100-06/system/log/logTrapHysteresis
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/3727/20/10/4/31

    Description by circitor

    This persistent variable indicates the desired hysteresis
    time value that allows the logging sub-system to generate
    a SNMP generic log trap, called 'logGenericTrap'. System
    events that are qualified as having an associated specific
    trap will NOT be allowed to generate a second generic
    trap.

    This control, allows a system event to be NORMALIZED
    within the 'logTrapHysteresis' time limit. If the event
    is not normlized, then the 'logGenericTrap' will be sent
    if not filtered by 'logTrapSeverityFilter', which also
    controls the generation of this trap. In addition
    trap management controls may filter this trap from being
    sent.

    'logTrapSeverityFilter', may restrict the generation of
    a trap based upon the severity level as specified in
    'logRecSeverity'.

    The units are in seconds with the default value value of
    120 which is the maximum allowed. The value of 0 is the
    minimum, which allows the trap to be generated
    immediately. The timing resolution is plus/minus 15
    seconds.

    Parsed from file WESTERN-MULTIPLEX-MIB.mib
    Module: WESTERN-MULTIPLEX-MIB

    Information by oid_info

    Vendor: Western Multiplex
    Module: WESTERN-MULTIPLEX-MIB

    [Automatically extracted from oidview.com]

    Information by circitor

    logTrapHysteresis OBJECT-TYPE SYNTAX INTEGER (0..120) ACCESS read-write STATUS mandatory DESCRIPTION "This persistent variable indicates the desired hysteresis time value that allows the logging sub-system to generate a SNMP generic log trap, called 'logGenericTrap'. System events that are qualified as having an associated specific trap will NOT be allowed to generate a second generic trap. This control, allows a system event to be NORMALIZED within the 'logTrapHysteresis' time limit. If the event is not normlized, then the 'logGenericTrap' will be sent if not filtered by 'logTrapSeverityFilter', which also controls the generation of this trap. In addition trap management controls may filter this trap from being sent. 'logTrapSeverityFilter', may restrict the generation of a trap based upon the severity level as specified in 'logRecSeverity'. The units are in seconds with the default value value of 120 which is the maximum allowed. The value of 0 is the minimum, which allows the trap to be generated immediately. The timing resolution is plus/minus 15 seconds." ::= { log 31 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.3727)

    Lee Herman

    Brothers (18)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.3727.20.10.4.1 logMaxSize 0 0 This persistent variable indicates the maximum size of
    the system event log. Some Western Multiplex platforms
    allow this variable…
    1.3.6.1.4.1.3727.20.10.4.2 logCurrentSize 0 0 This non-persistent variable indicates the current
    number of the system event log records.

    The non-persistent system event log is…
    1.3.6.1.4.1.3727.20.10.4.3 logIndexNumber 0 0 This non-persistent variable increments every time a
    system event is added to the system log. It has an
    initial value of 0.

    When …
    1.3.6.1.4.1.3727.20.10.4.4 logCurrentHEALTH 0 0 This non-persistent variable indicates the current
    health of the Network Management Unit, or NMU, System as
    determined by the con…
    1.3.6.1.4.1.3727.20.10.4.5 logRadioHEALTH 0 0 This non-persistent variable indicates the current
    health of the attached managed Radio system as determined
    by the contents of t…
    1.3.6.1.4.1.3727.20.10.4.6 logSeverityFilter 0 0 This persistent variable indicates the desired severity
    level for adding a system event to the log based upon a
    severity level. T…
    1.3.6.1.4.1.3727.20.10.4.7 logFilteredSpecific 0 0 This non-persistent variable counts the number of
    occurrences of system events that were not logged to
    the system log because of …
    1.3.6.1.4.1.3727.20.10.4.8 logFilteredSeverity 0 0 This non-persistent variable counts the number of
    occurrences of system events that where not logged to
    the system event log, bec…
    1.3.6.1.4.1.3727.20.10.4.9 logFilteredRules 0 0 This non-persistent variable increments every time a
    system event occurs, that is not added to the system log,
    because of replace…
    1.3.6.1.4.1.3727.20.10.4.15 logViewPageSize 0 0 This persistent variable determines the maximum
    size of the 'logRecTable', as returned to an SNMP user.

    For system that are conne…
    1.3.6.1.4.1.3727.20.10.4.16 logViewPageControl 0 0 This non-persistent variable allows a user to control
    the present page view of the 'logRecTable'.

    When 'logViewPageSize' is set …
    1.3.6.1.4.1.3727.20.10.4.17 logViewSeverityFilter 0 0 This persistent variable indicates the desired severity
    level or levels (and qualifiers) for viewing the
    'logRecTable'. This con…
    1.3.6.1.4.1.3727.20.10.4.18 logViewMethod 0 0 This persistent variable determines the sort method
    used for retrieving the 'logRecTable'.

    'chronological' allows the table to be…
    1.3.6.1.4.1.3727.20.10.4.19 logViewDirection 0 0 This persistent variable determines the direction
    of the severity related sorting of log records used for
    retrieving the 'logRecT…
    1.3.6.1.4.1.3727.20.10.4.20 logViewAge 0 0 This persistent variable determines the direction
    of the time related sorting of log records used for
    retrieving the 'logRecTable…
    1.3.6.1.4.1.3727.20.10.4.21 logViewEvents 0 0 This non-persistent variable indicates the number of
    system events that would be displayable on all pages of
    the 'logRecTable' gi…
    1.3.6.1.4.1.3727.20.10.4.30 logTrapSeverityFilter 0 0 This persistent variable indicates the desired severity
    level or levels (and qualifiers) for the logging
    sub-system to generate a…
    1.3.6.1.4.1.3727.20.10.4.40 logRecTable 1 5 This table contains system log events records.

    The non-persistent system event log is a circular history
    or log of system events.…