Status in source: mandatory.
Names: mtrapinfoCpEventId
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"mtrapinfoCpEventId",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"ACCESS",
"read-only",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"Allow CPS traps with an integer argument for providing detail information about Current Probe specific event identifier. Not being defined in the MIB, only reply 0. Known Specific Event ID: Current Probes 301 - Warning: Low charge current. 302 - Warning: High charge current. 303 - Alarm: Low charge current. 304 - Alarm: High charge current. 305 - Info: Charge current event has cleared. 306 - Warning: Low discharge current. 307 - Warning: High discharge current. 308 - Alarm: Low discharge current. 309 - Alarm: High discharge current. 310 - Info: Discharge current event has cleared. 311 - Warning: Low RMS current. 312 - Warning: High RMS current. 313 - Alarm: Low RMS current. 314 - Alarm: High RMS current. 315 - Info: RMS current event has cleared. 350 - Warning: Discharge. 351 - Alarm: Discharge. 352 - Info: Discharge event has cleared. 380 - Alarm: Number of current probe has decreased. 381 - Info: Number of current probe has increased. 382 - Info: Current probe configuration has been changed. \"",
"::=",
"{",
"mtrapinfo",
"7",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"Allow CPS traps with an integer argument for providing detail information about Current Probe specific event identifier. Not being defined in the MIB, only reply 0. Known Specific Event ID: Current Probes 301 - Warning: Low charge current. 302 - Warning: High charge current. 303 - Alarm: Low charge current. 304 - Alarm: High charge current. 305 - Info: Charge current event has cleared. 306 - Warning: Low discharge current. 307 - Warning: High discharge current. 308 - Alarm: Low discharge current. 309 - Alarm: High discharge current. 310 - Info: Discharge current event has cleared. 311 - Warning: Low RMS current. 312 - Warning: High RMS current. 313 - Alarm: Low RMS current. 314 - Alarm: High RMS current. 315 - Info: RMS current event has cleared. 350 - Warning: Discharge. 351 - Alarm: Discharge. 352 - Info: Discharge event has cleared. 380 - Alarm: Number of current probe has decreased. 381 - Info: Number of current probe has increased. 382 - Info: Current probe configuration has been changed."
],
null,
null,
null,
null
]
}
- Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
· Publisher's source file: CPS-MIB
Vendor MIB copy from the LibreNMS archive.
Module: CPS-MIB
See published definition above
Module imports
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises', 'Gauge', 'TimeTicks', 'IpAddress'], 'RFC1213-MIB': ['DisplayString']}
· Download CPS-MIB
Related source files and packages:
- Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
· Publisher's source file: Source package: observium-community-latest.tar.gz
Vendor MIB copy from the Observium Community archive.
Module: CPS-MIB
Same published definition
Module imports
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises', 'Gauge', 'TimeTicks', 'IpAddress'], 'RFC1213-MIB': ['DisplayString']}
· Download CPS-MIB
Related source files and packages: