OID reference

saIfaceStpBpduGuardEnable

1.3.6.1.4.1.3833.1.1.14.1.1.11.1.15

Description

Enabled or disabled the BPDU guard functionality per port. If BPDU guard functionality are global enabled (saSysStpBPDUGuardEnable=enable(1)), and BPDU guard are enabled per port (saIfaceStpBpduGuardEnable=enable(1)) and (R)STP are globally enabled and an BPDU are received on the port, then saIfaceStpBpduGuardStatus i…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.3833.1.1.14.1.1.11.1 (saInterfaceEntry)
Node code
15
Node name
saIfaceStpBpduGuardEnable
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.3833.1.1.14.1.1.11.1.15
URN notation
urn:oid:1.3.6.1.4.1.3833.1.1.14.1.1.11.1.15
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 3833 1 1 14 1 1 11 1 15}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderElectric(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saChassis(1) saSystemTable(1) saInterfaceTable(11) saInterfaceEntry(1) saIfaceStpBpduGuardEnable(15)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderElectric(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saChassis(1) saSystemTable(1) saInterfaceTable(11) saInterfaceEntry(1) saIfaceStpBpduGuardEnable(15)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) groupeschneider(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saChassis(1) saSystemTable(1) saInterfaceTable(11) saInterfaceEntry(1) saIfaceStpBpduGuardEnable(15)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) groupeschneider(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saChassis(1) saSystemTable(1) saInterfaceTable(11) saInterfaceEntry(1) saIfaceStpBpduGuardEnable(15)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderelectric(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saChassis(1) saSystemTable(1) saInterfaceTable(11) saInterfaceEntry(1) saIfaceStpBpduGuardEnable(15)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderelectric(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saChassis(1) saSystemTable(1) saInterfaceTable(11) saInterfaceEntry(1) saIfaceStpBpduGuardEnable(15)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderElectric(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saChassis(1) saSystemTable(1) saInterfaceTable(11) saInterfaceEntry(1) saIfaceStpBpduGuardEnable(15)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderElectric(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saChassis(1) saSystemTable(1) saInterfaceTable(11) saInterfaceEntry(1) saIfaceStpBpduGuardEnable(15)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) groupeschneider(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saChassis(1) saSystemTable(1) saInterfaceTable(11) saInterfaceEntry(1) saIfaceStpBpduGuardEnable(15)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) groupeschneider(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saChassis(1) saSystemTable(1) saInterfaceTable(11) saInterfaceEntry(1) saIfaceStpBpduGuardEnable(15)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderelectric(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saChassis(1) saSystemTable(1) saInterfaceTable(11) saInterfaceEntry(1) saIfaceStpBpduGuardEnable(15)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderelectric(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saChassis(1) saSystemTable(1) saInterfaceTable(11) saInterfaceEntry(1) saIfaceStpBpduGuardEnable(15)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) schneiderElectric(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saChassis(1) saSystemTable(1) saInterfaceTable(11) saInterfaceEntry(1) saIfaceStpBpduGuardEnable(15)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) schneiderElectric(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saChassis(1) saSystemTable(1) saInterfaceTable(11) saInterfaceEntry(1) saIfaceStpBpduGuardEnable(15)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) groupeschneider(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saChassis(1) saSystemTable(1) saInterfaceTable(11) saInterfaceEntry(1) saIfaceStpBpduGuardEnable(15)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) groupeschneider(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saChassis(1) saSystemTable(1) saInterfaceTable(11) saInterfaceEntry(1) saIfaceStpBpduGuardEnable(15)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/3833/1/1/14/1/1/11/1/15
  • /ISO/Identified-Organization/6/1/4/1/3833/1/1/14/1/1/11/1/15
  • /ISO/3/6/1/4/1/3833/1/1/14/1/1/11/1/15
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/schneiderElectric/transparentFactoryEthernet/switch/saConfiguration/saChassis/saSystemTable/saInterfaceTable/saInterfaceEntry/saIfaceStpBpduGuardEnable
  • /iso/identified-organization/dod/internet/private/enterprise/schneiderElectric/schneiderEnergy/switch/saConfiguration/saChassis/saSystemTable/saInterfaceTable/saInterfaceEntry/saIfaceStpBpduGuardEnable
  • /iso/identified-organization/dod/internet/private/enterprise/groupeschneider/transparentFactoryEthernet/switch/saConfiguration/saChassis/saSystemTable/saInterfaceTable/saInterfaceEntry/saIfaceStpBpduGuardEnable
  • /iso/identified-organization/dod/internet/private/enterprise/groupeschneider/schneiderEnergy/switch/saConfiguration/saChassis/saSystemTable/saInterfaceTable/saInterfaceEntry/saIfaceStpBpduGuardEnable
  • /iso/identified-organization/dod/internet/private/enterprise/schneiderelectric/transparentFactoryEthernet/switch/saConfiguration/saChassis/saSystemTable/saInterfaceTable/saInterfaceEntry/saIfaceStpBpduGuardEnable
  • /iso/identified-organization/dod/internet/private/enterprise/schneiderelectric/schneiderEnergy/switch/saConfiguration/saChassis/saSystemTable/saInterfaceTable/saInterfaceEntry/saIfaceStpBpduGuardEnable
  • /iso/identified-organization/dod/internet/private/enterprises/schneiderElectric/transparentFactoryEthernet/switch/saConfiguration/saChassis/saSystemTable/saInterfaceTable/saInterfaceEntry/saIfaceStpBpduGuardEnable
  • /iso/identified-organization/dod/internet/private/enterprises/schneiderElectric/schneiderEnergy/switch/saConfiguration/saChassis/saSystemTable/saInterfaceTable/saInterfaceEntry/saIfaceStpBpduGuardEnable
  • /iso/identified-organization/dod/internet/private/enterprises/groupeschneider/transparentFactoryEthernet/switch/saConfiguration/saChassis/saSystemTable/saInterfaceTable/saInterfaceEntry/saIfaceStpBpduGuardEnable
  • /iso/identified-organization/dod/internet/private/enterprises/groupeschneider/schneiderEnergy/switch/saConfiguration/saChassis/saSystemTable/saInterfaceTable/saInterfaceEntry/saIfaceStpBpduGuardEnable
  • /iso/identified-organization/dod/internet/private/enterprises/schneiderelectric/transparentFactoryEthernet/switch/saConfiguration/saChassis/saSystemTable/saInterfaceTable/saInterfaceEntry/saIfaceStpBpduGuardEnable
  • /iso/identified-organization/dod/internet/private/enterprises/schneiderelectric/schneiderEnergy/switch/saConfiguration/saChassis/saSystemTable/saInterfaceTable/saInterfaceEntry/saIfaceStpBpduGuardEnable
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/schneiderElectric/transparentFactoryEthernet/switch/saConfiguration/saChassis/saSystemTable/saInterfaceTable/saInterfaceEntry/saIfaceStpBpduGuardEnable
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/schneiderElectric/schneiderEnergy/switch/saConfiguration/saChassis/saSystemTable/saInterfaceTable/saInterfaceEntry/saIfaceStpBpduGuardEnable
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/groupeschneider/transparentFactoryEthernet/switch/saConfiguration/saChassis/saSystemTable/saInterfaceTable/saInterfaceEntry/saIfaceStpBpduGuardEnable
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/groupeschneider/schneiderEnergy/switch/saConfiguration/saChassis/saSystemTable/saInterfaceTable/saInterfaceEntry/saIfaceStpBpduGuardEnable
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
mandatory

Enumerated values

ValueName
1enable
2disable

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.

In TFPRIVATE-MIB, the row index consists of these components in order:

  1. saIfaceGroupID (INTEGER): one numeric subidentifier for the non-negative value.
  2. saIfaceID (INTEGER): one numeric subidentifier for the non-negative value.

An instance has the form .1.3.6.1.4.1.3833.1.1.14.1.1.11.1.15.<saIfaceGroupID>.<saIfaceID>. Use values present on the device and permitted by its MIB. Other definitions can differ.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.3833.1.1.14.1.1.11.1.15

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

saIfaceStpBpduGuardEnable	OBJECT-TYPE
			 SYNTAX 		 INTEGER {
							 enable (1),
							 disable (2)
							 }
			 ACCESS 		 read-write
			 STATUS 		 mandatory
			 DESCRIPTION
                 "Enabled or disabled the BPDU guard functionality per port.
                 If BPDU guard functionality are global enabled (saSysStpBPDUGuardEnable=enable(1)),
                 and BPDU guard are enabled per port (saIfaceStpBpduGuardEnable=enable(1)) and (R)STP are globally enabled
                 and an BPDU are received on the port, then saIfaceStpBpduGuardStatus is set to true(1) for this port and 
                 IfAdminStatus for this port is set to down(2).
                 Variable saIfaceStpBpduGuardStatus can be resetted to their original value (=false) with switching BPDU guard
                 functionality globally off.
                 IfAdminStatus can be resetted to to their original values up() only manually.
                 The default value of saIfaceStpBpduGuardEnable is enable(1)."
			 ::= { saInterfaceEntry 15 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Enabled or disabled the BPDU guard functionality per port. If BPDU guard functionality are global enabled (saSysStpBPDUGuardEnable=enable(1)), and BPDU guard are enabled per port (saIfaceStpBpduGuardEnable=enable(1)) and (R)STP are globally enabled and an BPDU are received on the port, then saIfaceStpBpduGuardStatus is set to true(1) for this port and IfAdminStatus for this port is set to down(2). Variable saIfaceStpBpduGuardStatus can be resetted to their original value (=false) with switching BPDU guard functionality globally off. IfAdminStatus can be resetted to to their original values up() only manually. The default value of saIfaceStpBpduGuardEnable is enable(1).

Sources for this description

Schneider Electric Transparent Factory official MIB

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Schneider Electric Transparent Factory official MIB1 record · 1 source

Description 1

saIfaceStpBpduGuardEnable · mandatorySchneider Electric Transparent Factory official MIB1 source

Status in source: mandatory.

Names: saIfaceStpBpduGuardEnable

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "saIfaceStpBpduGuardEnable",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "enable",
    "(",
    "1",
    ")",
    ",",
    "disable",
    "(",
    "2",
    ")",
    "}",
    "ACCESS",
    "read-write",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"Enabled or disabled the BPDU guard functionality per port. If BPDU guard functionality are global enabled (saSysStpBPDUGuardEnable=enable(1)), and BPDU guard are enabled per port (saIfaceStpBpduGuardEnable=enable(1)) and (R)STP are globally enabled and an BPDU are received on the port, then saIfaceStpBpduGuardStatus is set to true(1) for this port and IfAdminStatus for this port is set to down(2). Variable saIfaceStpBpduGuardStatus can be resetted to their original value (=false) with switching BPDU guard functionality globally off. IfAdminStatus can be resetted to to their original values up() only manually. The default value of saIfaceStpBpduGuardEnable is enable(1).\"",
    "::=",
    "{",
    "saInterfaceEntry",
    "15",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "enable",
            1
          ],
          [
            "disable",
            2
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "Enabled or disabled the BPDU guard functionality per port. If BPDU guard functionality are global enabled (saSysStpBPDUGuardEnable=enable(1)), and BPDU guard are enabled per port (saIfaceStpBpduGuardEnable=enable(1)) and (R)STP are globally enabled and an BPDU are received on the port, then saIfaceStpBpduGuardStatus is set to true(1) for this port and IfAdminStatus for this port is set to down(2). Variable saIfaceStpBpduGuardStatus can be resetted to their original value (=false) with switching BPDU guard functionality globally off. IfAdminStatus can be resetted to to their original values up() only manually. The default value of saIfaceStpBpduGuardEnable is enable(1)."
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.3833)

Dube Dennis

Siblings (15)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.3833.1.1.14.1.1.11.1.1 saIfaceGroupID00
1.3.6.1.4.1.3833.1.1.14.1.1.11.1.2 saIfaceID00
1.3.6.1.4.1.3833.1.1.14.1.1.11.1.3 saIfaceStpEnable00
1.3.6.1.4.1.3833.1.1.14.1.1.11.1.4 saIfaceLinkType00
1.3.6.1.4.1.3833.1.1.14.1.1.11.1.5 saIfaceAction00
1.3.6.1.4.1.3833.1.1.14.1.1.11.1.6 saIfaceNextHopMacAddress00
1.3.6.1.4.1.3833.1.1.14.1.1.11.1.7 saIfaceFlowControl00
1.3.6.1.4.1.3833.1.1.14.1.1.11.1.8 saIfacePriorityThreshold00
1.3.6.1.4.1.3833.1.1.14.1.1.11.1.9 saIfaceName00
1.3.6.1.4.1.3833.1.1.14.1.1.11.1.10 saIfaceTrunkID00
1.3.6.1.4.1.3833.1.1.14.1.1.11.1.11 saIfacePrioTOSEnable00
1.3.6.1.4.1.3833.1.1.14.1.1.11.1.12 saIfaceBcastLimit00
1.3.6.1.4.1.3833.1.1.14.1.1.11.1.13 saIfaceUtilization00
1.3.6.1.4.1.3833.1.1.14.1.1.11.1.14 saIfaceUtilizationControlInterval00
1.3.6.1.4.1.3833.1.1.14.1.1.11.1.16 saIfaceStpBpduGuardStatus00