The macaddress of the next switch agent reachable via this interface. If the value is 0:0:0:0:0:0, no other switch is seen via this interface.
Sources for this description
Schneider Electric Transparent Factory official MIB
OID reference
1.3.6.1.4.1.3833.1.1.14.1.1.11.1.6
The macaddress of the next switch agent reachable via this interface. If the value is 0:0:0:0:0:0, no other switch is seen via this interface.
Identification
{1 3 6 1 4 1 3833 1 1 14 1 1 11 1 6}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
saIfaceNextHopMacAddress OBJECT-TYPE
SYNTAX PhysAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The macaddress of the next switch agent reachable via this
interface. If the value is 0:0:0:0:0:0, no other switch is
seen via this interface."
::= { saInterfaceEntry 6 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
The macaddress of the next switch agent reachable via this interface. If the value is 0:0:0:0:0:0, no other switch is seen via this interface.
Schneider Electric Transparent Factory official MIB
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: mandatory.
Names: saIfaceNextHopMacAddress
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"saIfaceNextHopMacAddress",
"OBJECT-TYPE",
"SYNTAX",
"PhysAddress",
"ACCESS",
"read-only",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"The macaddress of the next switch agent reachable via this interface. If the value is 0:0:0:0:0:0, no other switch is seen via this interface.\"",
"::=",
"{",
"saInterfaceEntry",
"6",
"}"
],
"syntax_tree": [
[
"row",
"PhysAddress"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"The macaddress of the next switch agent reachable via this interface. If the value is 0:0:0:0:0:0, no other switch is seen via this interface."
],
null,
null,
null,
null
]
}Module: TFPRIVATE-MIB
See published definition above
{'IF-MIB': ['ifIndex'], 'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'BRIDGE-MIB': ['BridgeId', 'dot1dStaticAddress'], 'RFC1155-SMI': ['IpAddress', 'Counter', 'TimeTicks', 'enterprises'], 'RFC1213-MIB': ['DisplayString', 'PhysAddress', 'mib-2'], 'Q-BRIDGE-MIB': ['VlanIndex', 'dot1qVlanIndex', 'dot1qFdbId'], 'IANAifType-MIB': ['IANAifType']}Source data warning: Official Schneider Electric MIB distributed in the M580 support package. The package contains distinct historical editions; applicability to a specific device or firmware is not established by this file alone.
· Download Schneider Electric SchneiderTFE-V01-04.mib — M580 support packageRelated source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.3833.1.1.14.1.1.11.1.1 | saIfaceGroupID | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.1.14.1.1.11.1.2 | saIfaceID | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.1.14.1.1.11.1.3 | saIfaceStpEnable | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.1.14.1.1.11.1.4 | saIfaceLinkType | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.1.14.1.1.11.1.5 | saIfaceAction | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.1.14.1.1.11.1.7 | saIfaceFlowControl | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.1.14.1.1.11.1.8 | saIfacePriorityThreshold | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.1.14.1.1.11.1.9 | saIfaceName | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.1.14.1.1.11.1.10 | saIfaceTrunkID | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.1.14.1.1.11.1.11 | saIfacePrioTOSEnable | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.1.14.1.1.11.1.12 | saIfaceBcastLimit | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.1.14.1.1.11.1.13 | saIfaceUtilization | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.1.14.1.1.11.1.14 | saIfaceUtilizationControlInterval | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.1.14.1.1.11.1.15 | saIfaceStpBpduGuardEnable | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.1.14.1.1.11.1.16 | saIfaceStpBpduGuardStatus | 0 | 0 |