Indicates whether an alarm for the signalling relay of the associated link will be produced or not, so you can mask the value of ifMauMediaAvailable.
Sources for this description
Schneider Electric Transparent Factory official MIB
OID reference
1.3.6.1.4.1.3833.1.1.14.1.10.4.1.2
Indicates whether an alarm for the signalling relay of the associated link will be produced or not, so you can mask the value of ifMauMediaAvailable.
Identification
{1 3 6 1 4 1 3833 1 1 14 1 10 4 1 2}
| Value | Name |
|---|---|
| 1 | on |
| 2 | off |
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.
In TFPRIVATE-MIB, the row index saSigLinkID is declared as INTEGER. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.3833.1.1.14.1.10.4.1.2.<saSigLinkID>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.3833.1.1.14.1.10.4.1.2
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
saSigLinkAlarm OBJECT-TYPE
SYNTAX INTEGER {
on (1),
off (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates whether an alarm for the signalling relay of the
associated link will be produced or not, so you can mask the
value of ifMauMediaAvailable."
::= { saSigLinkEntry 2 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Indicates whether an alarm for the signalling relay of the associated link will be produced or not, so you can mask the value of ifMauMediaAvailable.
Schneider Electric Transparent Factory official MIB
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: mandatory.
Names: saSigLinkAlarm
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"saSigLinkAlarm",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"on",
"(",
"1",
")",
",",
"off",
"(",
"2",
")",
"}",
"ACCESS",
"read-write",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"Indicates whether an alarm for the signalling relay of the associated link will be produced or not, so you can mask the value of ifMauMediaAvailable.\"",
"::=",
"{",
"saSigLinkEntry",
"2",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"on",
1
],
[
"off",
2
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"Indicates whether an alarm for the signalling relay of the associated link will be produced or not, so you can mask the value of ifMauMediaAvailable."
],
null,
null,
null,
null
]
}Module: TFPRIVATE-MIB
See published definition above
{'IF-MIB': ['ifIndex'], 'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'BRIDGE-MIB': ['BridgeId', 'dot1dStaticAddress'], 'RFC1155-SMI': ['IpAddress', 'Counter', 'TimeTicks', 'enterprises'], 'RFC1213-MIB': ['DisplayString', 'PhysAddress', 'mib-2'], 'Q-BRIDGE-MIB': ['VlanIndex', 'dot1qVlanIndex', 'dot1qFdbId'], 'IANAifType-MIB': ['IANAifType']}Source data warning: Official Schneider Electric MIB distributed in the M580 support package. The package contains distinct historical editions; applicability to a specific device or firmware is not established by this file alone.
· Download Schneider Electric SchneiderTFE-V01-04.mib — M580 support packageRelated source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.3833.1.1.14.1.10.4.1.1 | saSigLinkID | 0 | 0 |