OID reference

saNetPTPSyncInterval

1.3.6.1.4.1.3833.1.1.14.2.3.40.1.12

Description

The sync interval shall be the interval in seconds between successive Sync messages issued by master clocks. It shall have the same value for all clocks in a subdomain. The value of sync interval is a compromise between the inherent stability of the clocks, the responsiveness of the clocks in a subdomain to change, an…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.3833.1.1.14.2.3.40.1 (saNetPTPConfiguration)
Node code
12
Node name
saNetPTPSyncInterval
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.3833.1.1.14.2.3.40.1.12
URN notation
urn:oid:1.3.6.1.4.1.3833.1.1.14.2.3.40.1.12
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 3833 1 1 14 2 3 40 1 12}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderElectric(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saAgent(2) saNetwork(3) saNetPTPGroup(40) saNetPTPConfiguration(1) saNetPTPSyncInterval(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderElectric(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saAgent(2) saNetwork(3) saNetPTPGroup(40) saNetPTPConfiguration(1) saNetPTPSyncInterval(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) groupeschneider(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saAgent(2) saNetwork(3) saNetPTPGroup(40) saNetPTPConfiguration(1) saNetPTPSyncInterval(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) groupeschneider(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saAgent(2) saNetwork(3) saNetPTPGroup(40) saNetPTPConfiguration(1) saNetPTPSyncInterval(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderelectric(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saAgent(2) saNetwork(3) saNetPTPGroup(40) saNetPTPConfiguration(1) saNetPTPSyncInterval(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderelectric(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saAgent(2) saNetwork(3) saNetPTPGroup(40) saNetPTPConfiguration(1) saNetPTPSyncInterval(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderElectric(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saAgent(2) saNetwork(3) saNetPTPGroup(40) saNetPTPConfiguration(1) saNetPTPSyncInterval(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderElectric(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saAgent(2) saNetwork(3) saNetPTPGroup(40) saNetPTPConfiguration(1) saNetPTPSyncInterval(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) groupeschneider(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saAgent(2) saNetwork(3) saNetPTPGroup(40) saNetPTPConfiguration(1) saNetPTPSyncInterval(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) groupeschneider(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saAgent(2) saNetwork(3) saNetPTPGroup(40) saNetPTPConfiguration(1) saNetPTPSyncInterval(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderelectric(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saAgent(2) saNetwork(3) saNetPTPGroup(40) saNetPTPConfiguration(1) saNetPTPSyncInterval(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderelectric(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saAgent(2) saNetwork(3) saNetPTPGroup(40) saNetPTPConfiguration(1) saNetPTPSyncInterval(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) schneiderElectric(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saAgent(2) saNetwork(3) saNetPTPGroup(40) saNetPTPConfiguration(1) saNetPTPSyncInterval(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) schneiderElectric(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saAgent(2) saNetwork(3) saNetPTPGroup(40) saNetPTPConfiguration(1) saNetPTPSyncInterval(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) groupeschneider(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saAgent(2) saNetwork(3) saNetPTPGroup(40) saNetPTPConfiguration(1) saNetPTPSyncInterval(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) groupeschneider(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saAgent(2) saNetwork(3) saNetPTPGroup(40) saNetPTPConfiguration(1) saNetPTPSyncInterval(12)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/3833/1/1/14/2/3/40/1/12
  • /ISO/Identified-Organization/6/1/4/1/3833/1/1/14/2/3/40/1/12
  • /ISO/3/6/1/4/1/3833/1/1/14/2/3/40/1/12
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/schneiderElectric/transparentFactoryEthernet/switch/saConfiguration/saAgent/saNetwork/saNetPTPGroup/saNetPTPConfiguration/saNetPTPSyncInterval
  • /iso/identified-organization/dod/internet/private/enterprise/schneiderElectric/schneiderEnergy/switch/saConfiguration/saAgent/saNetwork/saNetPTPGroup/saNetPTPConfiguration/saNetPTPSyncInterval
  • /iso/identified-organization/dod/internet/private/enterprise/groupeschneider/transparentFactoryEthernet/switch/saConfiguration/saAgent/saNetwork/saNetPTPGroup/saNetPTPConfiguration/saNetPTPSyncInterval
  • /iso/identified-organization/dod/internet/private/enterprise/groupeschneider/schneiderEnergy/switch/saConfiguration/saAgent/saNetwork/saNetPTPGroup/saNetPTPConfiguration/saNetPTPSyncInterval
  • /iso/identified-organization/dod/internet/private/enterprise/schneiderelectric/transparentFactoryEthernet/switch/saConfiguration/saAgent/saNetwork/saNetPTPGroup/saNetPTPConfiguration/saNetPTPSyncInterval
  • /iso/identified-organization/dod/internet/private/enterprise/schneiderelectric/schneiderEnergy/switch/saConfiguration/saAgent/saNetwork/saNetPTPGroup/saNetPTPConfiguration/saNetPTPSyncInterval
  • /iso/identified-organization/dod/internet/private/enterprises/schneiderElectric/transparentFactoryEthernet/switch/saConfiguration/saAgent/saNetwork/saNetPTPGroup/saNetPTPConfiguration/saNetPTPSyncInterval
  • /iso/identified-organization/dod/internet/private/enterprises/schneiderElectric/schneiderEnergy/switch/saConfiguration/saAgent/saNetwork/saNetPTPGroup/saNetPTPConfiguration/saNetPTPSyncInterval
  • /iso/identified-organization/dod/internet/private/enterprises/groupeschneider/transparentFactoryEthernet/switch/saConfiguration/saAgent/saNetwork/saNetPTPGroup/saNetPTPConfiguration/saNetPTPSyncInterval
  • /iso/identified-organization/dod/internet/private/enterprises/groupeschneider/schneiderEnergy/switch/saConfiguration/saAgent/saNetwork/saNetPTPGroup/saNetPTPConfiguration/saNetPTPSyncInterval
  • /iso/identified-organization/dod/internet/private/enterprises/schneiderelectric/transparentFactoryEthernet/switch/saConfiguration/saAgent/saNetwork/saNetPTPGroup/saNetPTPConfiguration/saNetPTPSyncInterval
  • /iso/identified-organization/dod/internet/private/enterprises/schneiderelectric/schneiderEnergy/switch/saConfiguration/saAgent/saNetwork/saNetPTPGroup/saNetPTPConfiguration/saNetPTPSyncInterval
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/schneiderElectric/transparentFactoryEthernet/switch/saConfiguration/saAgent/saNetwork/saNetPTPGroup/saNetPTPConfiguration/saNetPTPSyncInterval
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/schneiderElectric/schneiderEnergy/switch/saConfiguration/saAgent/saNetwork/saNetPTPGroup/saNetPTPConfiguration/saNetPTPSyncInterval
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/groupeschneider/transparentFactoryEthernet/switch/saConfiguration/saAgent/saNetwork/saNetPTPGroup/saNetPTPConfiguration/saNetPTPSyncInterval
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/groupeschneider/schneiderEnergy/switch/saConfiguration/saAgent/saNetwork/saNetPTPGroup/saNetPTPConfiguration/saNetPTPSyncInterval
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
mandatory

Enumerated values

ValueName
1sec-1
2sec-2
8sec-8
16sec-16
64sec-64

Using this OID with SNMP

At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.

snmpget [connection options] DEVICE .1.3.6.1.4.1.3833.1.1.14.2.3.40.1.12.0

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

saNetPTPSyncInterval OBJECT-TYPE
		SYNTAX		INTEGER {
					sec-1  (1),
					sec-2  (2),
					sec-8  (8),
					sec-16 (16),
					sec-64 (64)
					}
		ACCESS		read-write
		STATUS		mandatory
		DESCRIPTION
			"The sync interval shall be the interval in seconds between
			successive Sync messages issued by master clocks. 
			It shall have the same value for all clocks in a subdomain.
			The value of sync interval is a compromise between the
			inherent stability of the clocks, the responsiveness of the
			clocks in a subdomain to change, and the communication load
			imposed by PTP. Allowed values are 1,2,8,16 and 64. 
			Changes are applied after the initialization with the init 
			key init-with-nvm or after reboot if the configuration was saved."
		::= { saNetPTPConfiguration 12 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

The sync interval shall be the interval in seconds between successive Sync messages issued by master clocks. It shall have the same value for all clocks in a subdomain. The value of sync interval is a compromise between the inherent stability of the clocks, the responsiveness of the clocks in a subdomain to change, and the communication load imposed by PTP. Allowed values are 1,2,8,16 and 64. Changes are applied after the initialization with the init key init-with-nvm or after reboot if the configuration was saved.

Sources for this description

Schneider Electric Transparent Factory official MIB

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Schneider Electric Transparent Factory official MIB1 record · 1 source

Description 1

saNetPTPSyncInterval · mandatorySchneider Electric Transparent Factory official MIB1 source

Status in source: mandatory.

Names: saNetPTPSyncInterval

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "saNetPTPSyncInterval",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "sec-1",
    "(",
    "1",
    ")",
    ",",
    "sec-2",
    "(",
    "2",
    ")",
    ",",
    "sec-8",
    "(",
    "8",
    ")",
    ",",
    "sec-16",
    "(",
    "16",
    ")",
    ",",
    "sec-64",
    "(",
    "64",
    ")",
    "}",
    "ACCESS",
    "read-write",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"The sync interval shall be the interval in seconds between successive Sync messages issued by master clocks. It shall have the same value for all clocks in a subdomain. The value of sync interval is a compromise between the inherent stability of the clocks, the responsiveness of the clocks in a subdomain to change, and the communication load imposed by PTP. Allowed values are 1,2,8,16 and 64. Changes are applied after the initialization with the init key init-with-nvm or after reboot if the configuration was saved.\"",
    "::=",
    "{",
    "saNetPTPConfiguration",
    "12",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "sec-1",
            1
          ],
          [
            "sec-2",
            2
          ],
          [
            "sec-8",
            8
          ],
          [
            "sec-16",
            16
          ],
          [
            "sec-64",
            64
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "The sync interval shall be the interval in seconds between successive Sync messages issued by master clocks. It shall have the same value for all clocks in a subdomain. The value of sync interval is a compromise between the inherent stability of the clocks, the responsiveness of the clocks in a subdomain to change, and the communication load imposed by PTP. Allowed values are 1,2,8,16 and 64. Changes are applied after the initialization with the init key init-with-nvm or after reboot if the configuration was saved."
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.3833)

Dube Dennis

Siblings (26)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.3833.1.1.14.2.3.40.1.1 saNetPTPEnable00
1.3.6.1.4.1.3833.1.1.14.2.3.40.1.2 saNetPTPAction00
1.3.6.1.4.1.3833.1.1.14.2.3.40.1.3 saNetPTPClockMode00
1.3.6.1.4.1.3833.1.1.14.2.3.40.1.4 saNetPTPSlavePort00
1.3.6.1.4.1.3833.1.1.14.2.3.40.1.5 saNetPTPIsSynchronized00
1.3.6.1.4.1.3833.1.1.14.2.3.40.1.6 saNetPTPSyncLowerBound00
1.3.6.1.4.1.3833.1.1.14.2.3.40.1.7 saNetPTPSyncUpperBound00
1.3.6.1.4.1.3833.1.1.14.2.3.40.1.8 saNetPTPClockStratum00
1.3.6.1.4.1.3833.1.1.14.2.3.40.1.9 saNetPTPClockIdentifier00
1.3.6.1.4.1.3833.1.1.14.2.3.40.1.10 saNetPTPClockVariance00
1.3.6.1.4.1.3833.1.1.14.2.3.40.1.11 saNetPTPPreferredMaster00
1.3.6.1.4.1.3833.1.1.14.2.3.40.1.13 saNetPTPSubdomainName00
1.3.6.1.4.1.3833.1.1.14.2.3.40.1.14 saNetPTPOffsetFromMasterNanoSecs00
1.3.6.1.4.1.3833.1.1.14.2.3.40.1.15 saNetPTPAbsMaxOffset00
1.3.6.1.4.1.3833.1.1.14.2.3.40.1.16 saNetPTPOneWayDelayNanoSecs00
1.3.6.1.4.1.3833.1.1.14.2.3.40.1.17 saNetPTPTimeSeconds00
1.3.6.1.4.1.3833.1.1.14.2.3.40.1.18 saNetPTPObservedDrift00
1.3.6.1.4.1.3833.1.1.14.2.3.40.1.19 saNetPTPPiIntegral00
1.3.6.1.4.1.3833.1.1.14.2.3.40.1.20 saNetPTPParentUUID00
1.3.6.1.4.1.3833.1.1.14.2.3.40.1.21 saNetPTPGrandmasterUUID00
1.3.6.1.4.1.3833.1.1.14.2.3.40.1.22 saNetPTPCurrentUTCOffset00
1.3.6.1.4.1.3833.1.1.14.2.3.40.1.23 saNetPTPleap5900
1.3.6.1.4.1.3833.1.1.14.2.3.40.1.24 saNetPTPleap6100
1.3.6.1.4.1.3833.1.1.14.2.3.40.1.25 saNetPTPStepsRemoved00
1.3.6.1.4.1.3833.1.1.14.2.3.40.1.26 saNetPTPEpochNumber00
1.3.6.1.4.1.3833.1.1.14.2.3.40.1.27 saNetPTPStaticDrift00