Status in source: mandatory.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"saNetPTPIsSynchronized",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"true",
"(",
"1",
")",
",",
"false",
"(",
"2",
")",
"}",
"ACCESS",
"read-only",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"If the clock is synchronized to the current Master this object is set to true. Otherwise it is set to false. The clock sets this object to true, if the offset (ns) to the current Master is less than saNetPTPSyncLowerBound. The clock sets this object to false, if the offset (ns) to the current Master is bigger than saNetPTPSyncUpperBound.\"",
"::=",
"{",
"saNetPTPConfiguration",
"5",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"true",
1
],
[
"false",
2
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"If the clock is synchronized to the current Master this object is set to true. Otherwise it is set to false. The clock sets this object to true, if the offset (ns) to the current Master is less than saNetPTPSyncLowerBound. The clock sets this object to false, if the offset (ns) to the current Master is bigger than saNetPTPSyncUpperBound."
],
null,
null,
null,
null
]
}