OID reference

port502XwayStation

1.3.6.1.4.1.3833.1.2.8.1.9

Description

The hostId of the XWAY address.

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.3833.1.2.8.1 (port502ConnEntry)
Node code
9
Node name
port502XwayStation
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.3833.1.2.8.1.9
URN notation
urn:oid:1.3.6.1.4.1.3833.1.2.8.1.9
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 3833 1 2 8 1 9}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderElectric(3833) transparentFactoryEthernet(1) port502Messaging(2) port502ConnTable(8) port502ConnEntry(1) port502XwayStation(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderElectric(3833) schneiderEnergy(1) port502Messaging(2) port502ConnTable(8) port502ConnEntry(1) port502XwayStation(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) groupeschneider(3833) transparentFactoryEthernet(1) port502Messaging(2) port502ConnTable(8) port502ConnEntry(1) port502XwayStation(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) groupeschneider(3833) schneiderEnergy(1) port502Messaging(2) port502ConnTable(8) port502ConnEntry(1) port502XwayStation(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderelectric(3833) transparentFactoryEthernet(1) port502Messaging(2) port502ConnTable(8) port502ConnEntry(1) port502XwayStation(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderelectric(3833) schneiderEnergy(1) port502Messaging(2) port502ConnTable(8) port502ConnEntry(1) port502XwayStation(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderElectric(3833) transparentFactoryEthernet(1) port502Messaging(2) port502ConnTable(8) port502ConnEntry(1) port502XwayStation(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderElectric(3833) schneiderEnergy(1) port502Messaging(2) port502ConnTable(8) port502ConnEntry(1) port502XwayStation(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) groupeschneider(3833) transparentFactoryEthernet(1) port502Messaging(2) port502ConnTable(8) port502ConnEntry(1) port502XwayStation(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) groupeschneider(3833) schneiderEnergy(1) port502Messaging(2) port502ConnTable(8) port502ConnEntry(1) port502XwayStation(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderelectric(3833) transparentFactoryEthernet(1) port502Messaging(2) port502ConnTable(8) port502ConnEntry(1) port502XwayStation(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderelectric(3833) schneiderEnergy(1) port502Messaging(2) port502ConnTable(8) port502ConnEntry(1) port502XwayStation(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) schneiderElectric(3833) transparentFactoryEthernet(1) port502Messaging(2) port502ConnTable(8) port502ConnEntry(1) port502XwayStation(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) schneiderElectric(3833) schneiderEnergy(1) port502Messaging(2) port502ConnTable(8) port502ConnEntry(1) port502XwayStation(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) groupeschneider(3833) transparentFactoryEthernet(1) port502Messaging(2) port502ConnTable(8) port502ConnEntry(1) port502XwayStation(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) groupeschneider(3833) schneiderEnergy(1) port502Messaging(2) port502ConnTable(8) port502ConnEntry(1) port502XwayStation(9)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/3833/1/2/8/1/9
  • /ISO/Identified-Organization/6/1/4/1/3833/1/2/8/1/9
  • /ISO/3/6/1/4/1/3833/1/2/8/1/9
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/schneiderElectric/transparentFactoryEthernet/port502Messaging/port502ConnTable/port502ConnEntry/port502XwayStation
  • /iso/identified-organization/dod/internet/private/enterprise/schneiderElectric/schneiderEnergy/port502Messaging/port502ConnTable/port502ConnEntry/port502XwayStation
  • /iso/identified-organization/dod/internet/private/enterprise/groupeschneider/transparentFactoryEthernet/port502Messaging/port502ConnTable/port502ConnEntry/port502XwayStation
  • /iso/identified-organization/dod/internet/private/enterprise/groupeschneider/schneiderEnergy/port502Messaging/port502ConnTable/port502ConnEntry/port502XwayStation
  • /iso/identified-organization/dod/internet/private/enterprise/schneiderelectric/transparentFactoryEthernet/port502Messaging/port502ConnTable/port502ConnEntry/port502XwayStation
  • /iso/identified-organization/dod/internet/private/enterprise/schneiderelectric/schneiderEnergy/port502Messaging/port502ConnTable/port502ConnEntry/port502XwayStation
  • /iso/identified-organization/dod/internet/private/enterprises/schneiderElectric/transparentFactoryEthernet/port502Messaging/port502ConnTable/port502ConnEntry/port502XwayStation
  • /iso/identified-organization/dod/internet/private/enterprises/schneiderElectric/schneiderEnergy/port502Messaging/port502ConnTable/port502ConnEntry/port502XwayStation
  • /iso/identified-organization/dod/internet/private/enterprises/groupeschneider/transparentFactoryEthernet/port502Messaging/port502ConnTable/port502ConnEntry/port502XwayStation
  • /iso/identified-organization/dod/internet/private/enterprises/groupeschneider/schneiderEnergy/port502Messaging/port502ConnTable/port502ConnEntry/port502XwayStation
  • /iso/identified-organization/dod/internet/private/enterprises/schneiderelectric/transparentFactoryEthernet/port502Messaging/port502ConnTable/port502ConnEntry/port502XwayStation
  • /iso/identified-organization/dod/internet/private/enterprises/schneiderelectric/schneiderEnergy/port502Messaging/port502ConnTable/port502ConnEntry/port502XwayStation
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/schneiderElectric/transparentFactoryEthernet/port502Messaging/port502ConnTable/port502ConnEntry/port502XwayStation
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/schneiderElectric/schneiderEnergy/port502Messaging/port502ConnTable/port502ConnEntry/port502XwayStation
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/groupeschneider/transparentFactoryEthernet/port502Messaging/port502ConnTable/port502ConnEntry/port502XwayStation
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/groupeschneider/schneiderEnergy/port502Messaging/port502ConnTable/port502ConnEntry/port502XwayStation
  • Additional combinations skipped.

SNMP properties

Value type
Integer32, INTEGER
Maximum access defined by MIB
read-only
Status in MIB
current, mandatory

Definitions may combine these properties differently.

Compare 2 source variants

Variant 1 — Schneider Electric Transparent Factory official MIB

Value type
Integer32
Maximum access defined by MIB
read-only
Status in MIB
current
Allowed ranges
0–63

Variant 2 — Schneider Electric Transparent Factory official MIB

Value type
INTEGER
Maximum access defined by MIB
read-only
Status in MIB
mandatory
Allowed ranges
0–63

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.

In TFPRIVATE-MIB, the row index consists of these components in order:

  1. port502ConnLocalPort (INTEGER): one numeric subidentifier for the non-negative value.
  2. port502ConnRemAddress (IpAddress): four numeric subidentifiers, one per IPv4 address octet.
  3. port502ConnRemPort (INTEGER): one numeric subidentifier for the non-negative value.
  4. port502XwayNet (INTEGER): one numeric subidentifier for the non-negative value.
  5. port502XwayStation (INTEGER): one numeric subidentifier for the non-negative value.

An instance has the form .1.3.6.1.4.1.3833.1.2.8.1.9.<port502ConnLocalPort>.<port502ConnRemAddress: four octets>.<port502ConnRemPort>.<port502XwayNet>.<port502XwayStation>. Use values present on the device and permitted by its MIB. Other definitions can differ.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.3833.1.2.8.1.9

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 2 distinct definitions; some records may not include a definition.

Show 2 published definitions

port502XwayStation · current

port502XwayStation OBJECT-TYPE
            SYNTAX  Integer32  (0..63)
            MAX-ACCESS  read-only
        --    STATUS  obsolete 
            STATUS  current
            DESCRIPTION
               "The hostId of the XWAY address."
            ::= { port502ConnEntry 9 }

port502XwayStation · mandatory

port502XwayStation OBJECT-TYPE
            SYNTAX  INTEGER (0..63)
            ACCESS  read-only
        --    STATUS  optional 
            STATUS  mandatory
            DESCRIPTION
               "The hostId of the XWAY address."
            ::= { port502ConnEntry 9 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Evidence

Source records

2 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Schneider Electric Transparent Factory official MIB2 records · 2 sources

Description 1

port502XwayStation · currentSchneider Electric Transparent Factory official MIB1 source

Status in source: current.

Names: port502XwayStation

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "port502XwayStation",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "63",
    ")",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"The hostId of the XWAY address.\"",
    "::=",
    "{",
    "port502ConnEntry",
    "9",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            63
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "The hostId of the XWAY address."
    ],
    null,
    null,
    null,
    null
  ]
}
port502XwayStation · mandatorySchneider Electric Transparent Factory official MIB1 source

Status in source: mandatory.

Names: port502XwayStation

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "port502XwayStation",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "(",
    "0",
    ".",
    ".",
    "63",
    ")",
    "ACCESS",
    "read-only",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"The hostId of the XWAY address.\"",
    "::=",
    "{",
    "port502ConnEntry",
    "9",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "integerSubType",
        [
          [
            0,
            63
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "The hostId of the XWAY address."
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.3833)

Dube Dennis

Siblings (8)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.3833.1.2.8.1.1 port502ConnLocalPort00
1.3.6.1.4.1.3833.1.2.8.1.2 port502ConnRemAddress00
1.3.6.1.4.1.3833.1.2.8.1.3 port502ConnRemPort00
1.3.6.1.4.1.3833.1.2.8.1.4 port502ConnType00
1.3.6.1.4.1.3833.1.2.8.1.5 port502ConnMsgIn00
1.3.6.1.4.1.3833.1.2.8.1.6 port502ConnMsgOut00
1.3.6.1.4.1.3833.1.2.8.1.7 port502ConnMsgErr00
1.3.6.1.4.1.3833.1.2.8.1.8 port502XwayNet00