OID reference

seHdpmACMeterVAR

1.3.6.1.4.1.3833.1.6000.1.4.2.1.7

Description

Total of Phase VAR (Reactive Energy, Q).

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.3833.1.6000.1.4.2.1 (seHdpmACMetersEntry)
Node code
7
Node name
seHdpmACMeterVAR
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.3833.1.6000.1.4.2.1.7
URN notation
urn:oid:1.3.6.1.4.1.3833.1.6000.1.4.2.1.7
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 3833 1 6000 1 4 2 1 7}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderElectric(3833) transparentFactoryEthernet(1) hdpm(6000) schneiderHDPM(1) seHdpmACMeters(4) seHdpmACMetersTable(2) seHdpmACMetersEntry(1) seHdpmACMeterVAR(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderElectric(3833) schneiderEnergy(1) hdpm(6000) schneiderHDPM(1) seHdpmACMeters(4) seHdpmACMetersTable(2) seHdpmACMetersEntry(1) seHdpmACMeterVAR(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) groupeschneider(3833) transparentFactoryEthernet(1) hdpm(6000) schneiderHDPM(1) seHdpmACMeters(4) seHdpmACMetersTable(2) seHdpmACMetersEntry(1) seHdpmACMeterVAR(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) groupeschneider(3833) schneiderEnergy(1) hdpm(6000) schneiderHDPM(1) seHdpmACMeters(4) seHdpmACMetersTable(2) seHdpmACMetersEntry(1) seHdpmACMeterVAR(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderelectric(3833) transparentFactoryEthernet(1) hdpm(6000) schneiderHDPM(1) seHdpmACMeters(4) seHdpmACMetersTable(2) seHdpmACMetersEntry(1) seHdpmACMeterVAR(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderelectric(3833) schneiderEnergy(1) hdpm(6000) schneiderHDPM(1) seHdpmACMeters(4) seHdpmACMetersTable(2) seHdpmACMetersEntry(1) seHdpmACMeterVAR(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderElectric(3833) transparentFactoryEthernet(1) hdpm(6000) schneiderHDPM(1) seHdpmACMeters(4) seHdpmACMetersTable(2) seHdpmACMetersEntry(1) seHdpmACMeterVAR(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderElectric(3833) schneiderEnergy(1) hdpm(6000) schneiderHDPM(1) seHdpmACMeters(4) seHdpmACMetersTable(2) seHdpmACMetersEntry(1) seHdpmACMeterVAR(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) groupeschneider(3833) transparentFactoryEthernet(1) hdpm(6000) schneiderHDPM(1) seHdpmACMeters(4) seHdpmACMetersTable(2) seHdpmACMetersEntry(1) seHdpmACMeterVAR(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) groupeschneider(3833) schneiderEnergy(1) hdpm(6000) schneiderHDPM(1) seHdpmACMeters(4) seHdpmACMetersTable(2) seHdpmACMetersEntry(1) seHdpmACMeterVAR(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderelectric(3833) transparentFactoryEthernet(1) hdpm(6000) schneiderHDPM(1) seHdpmACMeters(4) seHdpmACMetersTable(2) seHdpmACMetersEntry(1) seHdpmACMeterVAR(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderelectric(3833) schneiderEnergy(1) hdpm(6000) schneiderHDPM(1) seHdpmACMeters(4) seHdpmACMetersTable(2) seHdpmACMetersEntry(1) seHdpmACMeterVAR(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) schneiderElectric(3833) transparentFactoryEthernet(1) hdpm(6000) schneiderHDPM(1) seHdpmACMeters(4) seHdpmACMetersTable(2) seHdpmACMetersEntry(1) seHdpmACMeterVAR(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) schneiderElectric(3833) schneiderEnergy(1) hdpm(6000) schneiderHDPM(1) seHdpmACMeters(4) seHdpmACMetersTable(2) seHdpmACMetersEntry(1) seHdpmACMeterVAR(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) groupeschneider(3833) transparentFactoryEthernet(1) hdpm(6000) schneiderHDPM(1) seHdpmACMeters(4) seHdpmACMetersTable(2) seHdpmACMetersEntry(1) seHdpmACMeterVAR(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) groupeschneider(3833) schneiderEnergy(1) hdpm(6000) schneiderHDPM(1) seHdpmACMeters(4) seHdpmACMetersTable(2) seHdpmACMetersEntry(1) seHdpmACMeterVAR(7)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/3833/1/6000/1/4/2/1/7
  • /ISO/Identified-Organization/6/1/4/1/3833/1/6000/1/4/2/1/7
  • /ISO/3/6/1/4/1/3833/1/6000/1/4/2/1/7
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/schneiderElectric/transparentFactoryEthernet/hdpm/schneiderHDPM/seHdpmACMeters/seHdpmACMetersTable/seHdpmACMetersEntry/seHdpmACMeterVAR
  • /iso/identified-organization/dod/internet/private/enterprise/schneiderElectric/schneiderEnergy/hdpm/schneiderHDPM/seHdpmACMeters/seHdpmACMetersTable/seHdpmACMetersEntry/seHdpmACMeterVAR
  • /iso/identified-organization/dod/internet/private/enterprise/groupeschneider/transparentFactoryEthernet/hdpm/schneiderHDPM/seHdpmACMeters/seHdpmACMetersTable/seHdpmACMetersEntry/seHdpmACMeterVAR
  • /iso/identified-organization/dod/internet/private/enterprise/groupeschneider/schneiderEnergy/hdpm/schneiderHDPM/seHdpmACMeters/seHdpmACMetersTable/seHdpmACMetersEntry/seHdpmACMeterVAR
  • /iso/identified-organization/dod/internet/private/enterprise/schneiderelectric/transparentFactoryEthernet/hdpm/schneiderHDPM/seHdpmACMeters/seHdpmACMetersTable/seHdpmACMetersEntry/seHdpmACMeterVAR
  • /iso/identified-organization/dod/internet/private/enterprise/schneiderelectric/schneiderEnergy/hdpm/schneiderHDPM/seHdpmACMeters/seHdpmACMetersTable/seHdpmACMetersEntry/seHdpmACMeterVAR
  • /iso/identified-organization/dod/internet/private/enterprises/schneiderElectric/transparentFactoryEthernet/hdpm/schneiderHDPM/seHdpmACMeters/seHdpmACMetersTable/seHdpmACMetersEntry/seHdpmACMeterVAR
  • /iso/identified-organization/dod/internet/private/enterprises/schneiderElectric/schneiderEnergy/hdpm/schneiderHDPM/seHdpmACMeters/seHdpmACMetersTable/seHdpmACMetersEntry/seHdpmACMeterVAR
  • /iso/identified-organization/dod/internet/private/enterprises/groupeschneider/transparentFactoryEthernet/hdpm/schneiderHDPM/seHdpmACMeters/seHdpmACMetersTable/seHdpmACMetersEntry/seHdpmACMeterVAR
  • /iso/identified-organization/dod/internet/private/enterprises/groupeschneider/schneiderEnergy/hdpm/schneiderHDPM/seHdpmACMeters/seHdpmACMetersTable/seHdpmACMetersEntry/seHdpmACMeterVAR
  • /iso/identified-organization/dod/internet/private/enterprises/schneiderelectric/transparentFactoryEthernet/hdpm/schneiderHDPM/seHdpmACMeters/seHdpmACMetersTable/seHdpmACMetersEntry/seHdpmACMeterVAR
  • /iso/identified-organization/dod/internet/private/enterprises/schneiderelectric/schneiderEnergy/hdpm/schneiderHDPM/seHdpmACMeters/seHdpmACMetersTable/seHdpmACMetersEntry/seHdpmACMeterVAR
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/schneiderElectric/transparentFactoryEthernet/hdpm/schneiderHDPM/seHdpmACMeters/seHdpmACMetersTable/seHdpmACMetersEntry/seHdpmACMeterVAR
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/schneiderElectric/schneiderEnergy/hdpm/schneiderHDPM/seHdpmACMeters/seHdpmACMetersTable/seHdpmACMetersEntry/seHdpmACMeterVAR
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/groupeschneider/transparentFactoryEthernet/hdpm/schneiderHDPM/seHdpmACMeters/seHdpmACMetersTable/seHdpmACMetersEntry/seHdpmACMeterVAR
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/groupeschneider/schneiderEnergy/hdpm/schneiderHDPM/seHdpmACMeters/seHdpmACMetersTable/seHdpmACMetersEntry/seHdpmACMeterVAR
  • Additional combinations skipped.

SNMP properties

Value type
Integer32
Maximum access defined by MIB
read-only
Status in MIB
current

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition. The index encoding is not inferred here.

Published row index: seHdpmACMeterIndex.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.3833.1.6000.1.4.2.1.7

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Product context

Documented MIB packages

This OID is defined in a Schneider Electric HDPM6000 MIB distributed with these firmware packages:

A definition in a firmware package does not establish that every device implements it or permits access. Other firmware versions have not been verified here.

The displayed source records contain one distinct definition. Compare its source records.

seHdpmACMeterVAR OBJECT-TYPE
      SYNTAX      Integer32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "Total of Phase VAR (Reactive Energy, Q)."
      ::= { seHdpmACMetersEntry 7 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Total of Phase VAR (Reactive Energy, Q).

Sources for this description

Schneider Electric HDPM6000 official MIB

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Schneider Electric HDPM6000 official MIB1 record · 2 sources

Description 1

seHdpmACMeterVAR · currentSchneider Electric HDPM6000 official MIB2 sources

Status in source: current.

Names: seHdpmACMeterVAR

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "seHdpmACMeterVAR",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Total of Phase VAR (Reactive Energy, Q).\"",
    "::=",
    "{",
    "seHdpmACMetersEntry",
    "7",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32"
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Total of Phase VAR (Reactive Energy, Q)."
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.3833)

Dube Dennis

Siblings (16)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.3833.1.6000.1.4.2.1.1 seHdpmACMeterIndex00
1.3.6.1.4.1.3833.1.6000.1.4.2.1.2 seHdpmACMeterNumberOfPhases00
1.3.6.1.4.1.3833.1.6000.1.4.2.1.3 seHdpmACMeterVoltsRms00
1.3.6.1.4.1.3833.1.6000.1.4.2.1.4 seHdpmACMeterAmpsRms00
1.3.6.1.4.1.3833.1.6000.1.4.2.1.5 seHdpmACMeterPF00
1.3.6.1.4.1.3833.1.6000.1.4.2.1.6 seHdpmACMeterWatt00
1.3.6.1.4.1.3833.1.6000.1.4.2.1.8 seHdpmACMeterTHDv00
1.3.6.1.4.1.3833.1.6000.1.4.2.1.9 seHdpmACMeterTHDi00
1.3.6.1.4.1.3833.1.6000.1.4.2.1.10 seHdpmACMeterWh00
1.3.6.1.4.1.3833.1.6000.1.4.2.1.11 seHdpmACMeterVARh00
1.3.6.1.4.1.3833.1.6000.1.4.2.1.12 seHdpmACMeterFreq00
1.3.6.1.4.1.3833.1.6000.1.4.2.1.13 seHdpmACMeterAmpsRmsavg00
1.3.6.1.4.1.3833.1.6000.1.4.2.1.14 seHdpmACMeterVAh00
1.3.6.1.4.1.3833.1.6000.1.4.2.1.15 seHdpmACMeterCurrentImbalance00
1.3.6.1.4.1.3833.1.6000.1.4.2.1.16 seHdpmACMeterVoltageImbalance00
1.3.6.1.4.1.3833.1.6000.1.4.2.1.17 seHdpmACMeterTotalDemandDistortion00