Description 1
relay3 State
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.38783.3.4
relay3 State
Identification
{1 3 6 1 4 1 38783 3 4}
Definitions may combine these properties differently.
Numbers refer to source variants above. Each value is shown only for variants that define it.
| Value | Name | Source variants |
|---|---|---|
| 0 | off | 1, 3 |
| 1 | on | 1, 3 |
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
snmpget [connection options] DEVICE .1.3.6.1.4.1.38783.3.4.0
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 5 distinct definitions; some records may not include a definition.
relay3 OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"relay3 State"
::= { monitorNcontrol 4 }voltx10Int OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Voltage x10 in Integer format"
::= { monitorNcontrol 4 }relay1Pulse OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Relay1 Pulse"
::= { monitorNcontrol 4 }temperature OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..4))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Temperature"
::= { monitor 4 }tcw241MIBConformance OBJECT IDENTIFIER ::= { tcw241 4 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Description 1
relay3 State
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Description 2
Voltage x10 in Integer format
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Description 3
Relay1 Pulse
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Description 4
Temperature
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: relay3
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"relay3",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"off",
"(",
"0",
")",
",",
"on",
"(",
"1",
")",
"}",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"relay3 State\"",
"::=",
"{",
"monitorNcontrol",
"4",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"off",
0
],
[
"on",
1
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"relay3 State"
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: TERACOM-TCW181B-MIB
See published definition above
{'SNMPv2-TC': ['MacAddress', 'DisplayString'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises', 'IpAddress', 'Integer32', 'snmpModules'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP']}Related source files and packages:
Status in source: mandatory.
Names: voltx10Int
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"voltx10Int",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"(",
"0",
".",
".",
"65535",
")",
"ACCESS",
"read-only",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"Voltage x10 in Integer format\"",
"::=",
"{",
"monitorNcontrol",
"4",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"integerSubType",
[
[
0,
65535
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"Voltage x10 in Integer format"
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: TERACOM-TCW111-MIB
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises', 'IpAddress', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString']}Source data warning: Recovered from a file whose complete MIB does not parse. The original assignment and definition are preserved. Registration and implementation details may be inaccurate; consult the original file. Other damaged or unresolved declarations are not established registrations.
· Download TERACOM-TCW111-MIBStatus in source: mandatory.
Names: relay1Pulse
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"relay1Pulse",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"off",
"(",
"0",
")",
",",
"on",
"(",
"1",
")",
"}",
"ACCESS",
"read-write",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"Relay1 Pulse\"",
"::=",
"{",
"monitorNcontrol",
"4",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"off",
0
],
[
"on",
1
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"Relay1 Pulse"
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: TERACOM-TCW121-MIB
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises', 'IpAddress'], 'RFC1213-MIB': ['DisplayString']}Status in source: mandatory.
Names: temperature
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"temperature",
"OBJECT-TYPE",
"SYNTAX",
"DisplayString",
"(",
"SIZE",
"(",
"0",
".",
".",
"4",
")",
")",
"ACCESS",
"read-only",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"Temperature\"",
"::=",
"{",
"monitor",
"4",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"DisplayString",
[
"octetStringSubType",
[
[
0,
4
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"Temperature"
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: TERACOM-TCW120-MIB
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises', 'IpAddress', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString']}Vendor MIB copy from the Observium Community archive.
Module: TERACOM-TCW110-MIB
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises', 'IpAddress', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString']}Status in source: unspecified.
Names: tcw241MIBConformance
{
"smi_kind": "OBJECT IDENTIFIER",
"definition": [
"tcw241MIBConformance",
"OBJECT",
"IDENTIFIER",
"::=",
"{",
"tcw241",
"4",
"}"
]
}Vendor MIB copy from the LibreNMS archive.
Module: TERACOM-TCW241-MIB
See published definition above
{'SNMPv2-TC': ['DateAndTime', 'MacAddress', 'DisplayString', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises', 'IpAddress', 'Integer32', 'snmpModules'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP']}Related source files and packages:
Vendor MIB copy from the Observium Community archive.
Module: TERACOM-TCW241-MIB
{'SNMPv2-TC': ['DateAndTime', 'MacAddress', 'DisplayString', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises', 'IpAddress', 'Integer32', 'snmpModules'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP']}Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.38783.3.4.1 | tcw241MIBCompliances | 1 | 1 | |
| 1.3.6.1.4.1.38783.3.4.2 | tcw241MIBGroups | 4 | 4 |
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.38783.3.0 | trapNotifications | 1 | 1 | |
| 1.3.6.1.4.1.38783.3.1 | product, relays, digitalInput1State, digitalInput, digitalInputState | 4 | 4 | |
| 1.3.6.1.4.1.38783.3.2 | setup, analogs, digitalInput2State, relay1, relayState | 4 | 160 | |
| 1.3.6.1.4.1.38783.3.3 | monitorNcontrol, digitalInputs, relay1State, relay2, relayPulse | 11 | 115 | |
| 1.3.6.1.4.1.38783.3.5 | tempx10Int, relay2State, relay4 | 0 | 0 | |
| 1.3.6.1.4.1.38783.3.6 | relay2Pulse, relay5, humix10Int | 0 | 0 | |
| 1.3.6.1.4.1.38783.3.7 | voltage1x10Int, relay6, configurationSaved | 0 | 0 | |
| 1.3.6.1.4.1.38783.3.8 | voltage2x10Int, relay7, restartDevice | 0 | 0 | |
| 1.3.6.1.4.1.38783.3.9 | temp1x10Int, relay8 | 0 | 0 | |
| 1.3.6.1.4.1.38783.3.10 | temp2x10Int, pulse1 | 0 | 0 | |
| 1.3.6.1.4.1.38783.3.11 | humi1x10Int, pulse2 | 0 | 0 | |
| 1.3.6.1.4.1.38783.3.12 | humi2x10Int, pulse3 | 0 | 0 | |
| 1.3.6.1.4.1.38783.3.13 | configurationSaved, pulse4 | 0 | 0 | |
| 1.3.6.1.4.1.38783.3.14 | restartDevice, pulse5 | 0 | 0 | |
| 1.3.6.1.4.1.38783.3.15 | pulse6 | 0 | 0 | |
| 1.3.6.1.4.1.38783.3.16 | pulse7 | 0 | 0 | |
| 1.3.6.1.4.1.38783.3.17 | pulse8 | 0 | 0 | |
| 1.3.6.1.4.1.38783.3.18 | allOn | 0 | 0 | |
| 1.3.6.1.4.1.38783.3.19 | allOff | 0 | 0 | |
| 1.3.6.1.4.1.38783.3.20 | allPulse | 0 | 0 |