OID reference

voltage1x10Int

1.3.6.1.4.1.38783.3.7

Description

Configuration save status SAVED/UNSAVED

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.38783.3 (tcw241, monitor, monitorNcontrol)
Node code
7
Node names
  • voltage1x10Int
  • relay6
  • configurationSaved
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.38783.3.7
URN notation
urn:oid:1.3.6.1.4.1.38783.3.7
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 38783 3 7}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) teracom(38783) tcw241(3) voltage1x10Int(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) teracom(38783) tcw241(3) relay6(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) teracom(38783) tcw241(3) configurationSaved(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) teracom(38783) monitor(3) voltage1x10Int(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) teracom(38783) monitor(3) relay6(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) teracom(38783) monitor(3) configurationSaved(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) teracom(38783) monitorNcontrol(3) voltage1x10Int(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) teracom(38783) monitorNcontrol(3) relay6(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) teracom(38783) monitorNcontrol(3) configurationSaved(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) teracom(38783) tcw241(3) voltage1x10Int(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) teracom(38783) tcw241(3) relay6(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) teracom(38783) tcw241(3) configurationSaved(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) teracom(38783) monitor(3) voltage1x10Int(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) teracom(38783) monitor(3) relay6(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) teracom(38783) monitor(3) configurationSaved(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) teracom(38783) monitorNcontrol(3) voltage1x10Int(7)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/38783/3/7
  • /ISO/Identified-Organization/6/1/4/1/38783/3/7
  • /ISO/3/6/1/4/1/38783/3/7
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/38783/tcw241/voltage1x10Int
  • /iso/identified-organization/dod/internet/private/enterprise/38783/tcw241/relay6
  • /iso/identified-organization/dod/internet/private/enterprise/38783/tcw241/configurationSaved
  • /iso/identified-organization/dod/internet/private/enterprise/38783/monitor/voltage1x10Int
  • /iso/identified-organization/dod/internet/private/enterprise/38783/monitor/relay6
  • /iso/identified-organization/dod/internet/private/enterprise/38783/monitor/configurationSaved
  • /iso/identified-organization/dod/internet/private/enterprise/38783/monitorNcontrol/voltage1x10Int
  • /iso/identified-organization/dod/internet/private/enterprise/38783/monitorNcontrol/relay6
  • /iso/identified-organization/dod/internet/private/enterprise/38783/monitorNcontrol/configurationSaved
  • /iso/identified-organization/dod/internet/private/enterprise/teracom/tcw241/voltage1x10Int
  • /iso/identified-organization/dod/internet/private/enterprise/teracom/tcw241/relay6
  • /iso/identified-organization/dod/internet/private/enterprise/teracom/tcw241/configurationSaved
  • /iso/identified-organization/dod/internet/private/enterprise/teracom/monitor/voltage1x10Int
  • /iso/identified-organization/dod/internet/private/enterprise/teracom/monitor/relay6
  • /iso/identified-organization/dod/internet/private/enterprise/teracom/monitor/configurationSaved
  • /iso/identified-organization/dod/internet/private/enterprise/teracom/monitorNcontrol/voltage1x10Int
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-write, read-only
Status in MIB
mandatory, current

Definitions may combine these properties differently.

Compare 3 source variants

Variant 1 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
mandatory

Variant 2 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
current

Variant 3 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
INTEGER
Maximum access defined by MIB
read-only
Status in MIB
mandatory
Allowed ranges
0–1000

Enumerated values

Numbers refer to source variants above. Each value is shown only for variants that define it.

ValueNameSource variants
0UNSAVED1
0off2
1SAVED1
1on2

Using this OID with SNMP

At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.

snmpget [connection options] DEVICE .1.3.6.1.4.1.38783.3.7.0

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 3 distinct definitions; some records may not include a definition.

Show 3 published definitions

configurationSaved · mandatory

configurationSaved OBJECT-TYPE
	SYNTAX INTEGER { SAVED(1), UNSAVED(0) }
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Configuration save status SAVED/UNSAVED"
	::= { monitorNcontrol 7 }

relay6 · current

relay6 OBJECT-TYPE
    SYNTAX INTEGER { off(0), on(1) }
    MAX-ACCESS  read-write
    STATUS current
    DESCRIPTION
        "relay6 State"
    ::= { monitorNcontrol 7 }

voltage1x10Int · mandatory

voltage1x10Int OBJECT-TYPE
    SYNTAX INTEGER (0..1000)
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION 
        "Voltage1 x10 in Integer format"
    ::= { monitorNcontrol 7 }

Meaning

Descriptions

3 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 1

Configuration save status SAVED/UNSAVED

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 2

relay6 State

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 3

Voltage1 x10 in Integer format

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

3 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 1

configurationSaved · mandatoryMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: mandatory.

Names: configurationSaved

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "configurationSaved",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "SAVED",
    "(",
    "1",
    ")",
    ",",
    "UNSAVED",
    "(",
    "0",
    ")",
    "}",
    "ACCESS",
    "read-write",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"Configuration save status SAVED/UNSAVED\"",
    "::=",
    "{",
    "monitorNcontrol",
    "7",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "SAVED",
            1
          ],
          [
            "UNSAVED",
            0
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "Configuration save status SAVED/UNSAVED"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 2Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 2

relay6 · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: relay6

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "relay6",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "off",
    "(",
    "0",
    ")",
    ",",
    "on",
    "(",
    "1",
    ")",
    "}",
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"relay6 State\"",
    "::=",
    "{",
    "monitorNcontrol",
    "7",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "off",
            0
          ],
          [
            "on",
            1
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "relay6 State"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 3Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 3

voltage1x10Int · mandatoryMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: mandatory.

Names: voltage1x10Int

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "voltage1x10Int",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "(",
    "0",
    ".",
    ".",
    "1000",
    ")",
    "ACCESS",
    "read-only",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"Voltage1 x10 in Integer format\"",
    "::=",
    "{",
    "monitorNcontrol",
    "7",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "integerSubType",
        [
          [
            0,
            1000
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "Voltage1 x10 in Integer format"
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.38783)

Ognyan Dimitrov

Siblings (20)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.38783.3.0 trapNotifications11
1.3.6.1.4.1.38783.3.1 product, relays, digitalInput1State, digitalInput, digitalInputState44
1.3.6.1.4.1.38783.3.2 setup, analogs, digitalInput2State, relay1, relayState4160
1.3.6.1.4.1.38783.3.3 monitorNcontrol, digitalInputs, relay1State, relay2, relayPulse11115
1.3.6.1.4.1.38783.3.4 tcw241MIBConformance, temperature, relay1Pulse, relay3, voltx10Int27
1.3.6.1.4.1.38783.3.5 tempx10Int, relay2State, relay400
1.3.6.1.4.1.38783.3.6 relay2Pulse, relay5, humix10Int00
1.3.6.1.4.1.38783.3.8 voltage2x10Int, relay7, restartDevice00
1.3.6.1.4.1.38783.3.9 temp1x10Int, relay800
1.3.6.1.4.1.38783.3.10 temp2x10Int, pulse100
1.3.6.1.4.1.38783.3.11 humi1x10Int, pulse200
1.3.6.1.4.1.38783.3.12 humi2x10Int, pulse300
1.3.6.1.4.1.38783.3.13 configurationSaved, pulse400
1.3.6.1.4.1.38783.3.14 restartDevice, pulse500
1.3.6.1.4.1.38783.3.15 pulse600
1.3.6.1.4.1.38783.3.16 pulse700
1.3.6.1.4.1.38783.3.17 pulse800
1.3.6.1.4.1.38783.3.18 allOn00
1.3.6.1.4.1.38783.3.19 allOff00
1.3.6.1.4.1.38783.3.20 allPulse00