Status in source: current.
Names: zxAnXdsl2LineStatusElectricalLength
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"zxAnXdsl2LineStatusElectricalLength",
"OBJECT-TYPE",
"SYNTAX",
"Unsigned32",
"(",
"0",
".",
".",
"1280",
")",
"UNITS",
[
"literal",
"22302e3120644222"
],
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"(UPBOKLE) This parameter contains the estimated electrical length expressed in dB at 1 MHz, kl0. This is the final electrical length that would have been sent from the VTU-O to VTU-R if the electrical length was not forced by the CO-MIB. The value ranges from 0 to 128 dB in steps of 0.1 dB.\"",
"REFERENCE",
"\"ITU-T G.997.1, paragraph #7.5.1.23\"",
"DEFVAL",
"{",
"0",
"}",
"::=",
"{",
"zxAnXdsl2LineEntry",
"28",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Unsigned32",
[
"integerSubType",
[
[
0,
1280
]
]
]
],
[
"UNITS",
"0.1 dB"
],
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"(UPBOKLE) This parameter contains the estimated electrical length expressed in dB at 1 MHz, kl0. This is the final electrical length that would have been sent from the VTU-O to VTU-R if the electrical length was not forced by the CO-MIB. The value ranges from 0 to 128 dB in steps of 0.1 dB."
],
[
"REFERENCE",
"ITU-T G.997.1, paragraph #7.5.1.23"
],
null,
null,
[
"DEFVAL",
0
]
]
}