This object specifies the minimum interval, in microseconds, that the local system would like to use when transmitting BFD Control packets.
Sources for this description
ZTE MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.3902.1015.16.1.2.1.23
This object specifies the minimum interval, in microseconds, that the local system would like to use when transmitting BFD Control packets.
Identification
{1 3 6 1 4 1 3902 1015 16 1 2 1 23}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
zxAnBfdStdSessDesiredMinTxIntv OBJECT-TYPE
SYNTAX ZxAnBfdStdInterval
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object specifies the minimum interval, in
microseconds, that the local system would like to use when
transmitting BFD Control packets."
::= { zxAnBfdStdSessEntry 23 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
This object specifies the minimum interval, in microseconds, that the local system would like to use when transmitting BFD Control packets.
ZTE MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: zxAnBfdStdSessDesiredMinTxIntv
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"zxAnBfdStdSessDesiredMinTxIntv",
"OBJECT-TYPE",
"SYNTAX",
"ZxAnBfdStdInterval",
"MAX-ACCESS",
"read-create",
"STATUS",
"current",
"DESCRIPTION",
"\"This object specifies the minimum interval, in microseconds, that the local system would like to use when transmitting BFD Control packets.\"",
"::=",
"{",
"zxAnBfdStdSessEntry",
"23",
"}"
],
"syntax_tree": [
[
"row",
"ZxAnBfdStdInterval"
],
null,
[
"MaxAccessPart",
"read-create"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This object specifies the minimum interval, in microseconds, that the local system would like to use when transmitting BFD Control packets."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive. ZTE support.
Module: ZTE-AN-BFD-STD-MIB
See published definition above
{'IF-MIB': ['InterfaceIndexOrZero'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'TruthValue', 'RowStatus', 'StorageType', 'TimeStamp'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'mib-2', 'Integer32', 'Unsigned32', 'Counter32', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'ZTE-AN-TC-MIB': ['zxAn'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType', 'InetPortNumber']}Related source files and packages:
Registration